Siebel Life Sciences Guide > Managing Pharma Samples >

Managing Inventory Tracking and Reconciliation Without Lot Numbers


Siebel Samples Management supports using lot numbers for samples creation, shipment, receipt, transfers, adjustment, ordering, and disbursement while not using lot numbers for inventory and reconciliation.

To enable this behavior, you must make three changes:

  • Set the value of two system preferences—Samples Lots Enabled and Lots for Disperse Only—to "True."
  • Check the Lot# Tracking flag in the Product Administration screen.
  • Implement product visibility. For more information, see Retaining Sample Product Visibility.

When this behavior has been enabled, the Lot No. field is available but not required for samples creation, shipment, receipt, transfers, adjustment, ordering and call reporting. In addition, the Lot No. field is disabled in the Inventory Count and Reconciliation views.

To track and reconcile inventory without lot numbers

  1. Set the Samples Lots Enabled system preference to TRUE.
  2. Set the Lots for Disperse Only system preference to TRUE.

    For general information about setting system preferences, see the Siebel Applications Administration Guide.

To create and submit initial count adjustments

  1. Navigate to the Samples screen.
  2. On the link bar, click Sample Adjustments.
  3. In the My Samples Adjustments list, create a new record and complete the necessary fields.

    Some fields are described in the following table.

    Field
    Comments

    Adjustment Reason

    Select Initial Count from the drop-down list.

    Inventory Period

    Selecting an Inventory Period automatically enters a validated date in the Transaction Date (Txn Date) field, making sure that the adjustment is entered into the appropriate inventory period.

    Transaction #

    The application automatically generates an unique identifier. You can change this value.

    Transaction Date

    It is recommended that you complete the Inventory Period field to auto-fill this field so that the adjustment is entered into the correct period.

    Transaction Status

    The application automatically changes this field value to Submitted when you submit the adjustment.

  4. In the Line Items list, create a new record and complete the necessary fields.

    Some fields are described in the following table.

    Field
    Comments

    Item #

    The application automatically generates this value. If you want to have the items appear in a particular order, edit this value in the Product Administration screen.

    Item Status

    The application automatically changes this field value to Submitted when you submit the transaction.

    Lot Name

    The lot number for this sample.

    Quantity

    The amount of your initial inventory. This quantity should be the same as the value you entered in the Count field in the Inventory Count view. For more information, see To add products to inventory and submit an initial count).

    Sample

    The sample to be adjusted.

    Repeat Step 3 and Step 4 to enter a line item for each sample needing adjustment.

  5. Click Submit.

    The values in the Transaction Status field (in the Samples Adjustment form) and the Item Status fields (in the Line Items list) are changed to Submitted.

Reconcile the initial inventory period, as described in the next procedure.

To reconcile the initial inventory period

  1. Navigate to the Samples screen.
  2. On the link bar, click Reconciliation.

    The Reconciliation view contains the following lists.

    List
    Description

    Unreconciled Inventory Periods

    Shows all inactive (past, unreconciled) inventory periods. An active period becomes inactive once you submit an inventory count for the period (as described in To add products to inventory and submit an initial count).

    Unreconciled Inventory

    Shows the products in your inventory, their physical and electronic counts, and the difference between the two counts (if any). The Difference field must be zero for all products before you can reconcile the period.

    Samples History

    Shows samples transactions entered for the currently selected product in the Unreconciled Inventory list. If no transactions were entered for the selected product during the inactive inventory period, this list is empty.

  3. In the Unreconciled Inventory list, verify that the Difference field shows zero for the products listed.

    If a product shows a value other than zero, you must make an adjustment to correct the difference. For more information, see Adjusting a Past Samples Transaction.

  4. In the Unreconciled Inventory Periods list, click Reconcile.

    The lists in the view are cleared.

  5. From the Show drop-down list, select My Samples History.

    The Samples History view appears. In the Inventory Periods list, a check mark appears in the Reconciled field of the inactive period that you just reconciled.