Siebel Global Deployment Guide > Deploying with Global Time Zone > Converting Historical Data to UTC >
Reviewing the UTC Conversion Log Files
This topic is part of Converting Historical Data to UTC. After the UTC conversion utility runs, if errors are encountered, the utility records those errors to log files. The log files are located in the log subdirectory of SIEBSRVR_ROOT. Carefully review the log files for errors. Some of the errors listed in the log file are acceptable, but others will require resolution. An example of an acceptable error is when the utc_drop_temp_tab.log file generates the error "ORA-00942: table or view does not exist" when initially dropping the S_CONTACT_TMP and S_TIMEZONE_TMP tables. The default log files are listed below. You may have additional log files if you modified the input files. utc_drop_temp_tab.log null_timezone.log utc_insert_to_tmp_tab.log utc_create_tmp_ind.log utc_run_stats.log s_camp_con_00.log s_camp_con_01.log s_camp_con_02.log s_camp_con_03.log s_communication_00.log s_communication_01.log s_communication_02.log s_communication_03.log s_evt_act_00.log s_evt_act_01.log s_evt_act_02.log s_evt_act_03.log s_evt_act_04.log s_evt_act_05.log s_contact.log s_org_ext.log s_srv_req.log utc_columns.log denorm.log utc_drop_temp_tab2.log
Review the log files that were generated by the UTC conversion utility, including any custom log files that you may have created, and resolve errors as necessary. If the UTC conversion utility was interrupted after it encountered an error, you need to manually relaunch the UTC conversion utility.
|