Bookshelf Home | Contents | Index | Search | PDF |
Transports and Interfaces: Siebel eBusiness Application Integration Volume III > Using Siebel OLE DB Provider >
Troubleshooting OLE DB
This section describes common connection problems when using OLE DB. Consult the Windows Event Log to view the details on other OLE DB and Siebel OLE DB Provider errors.
Error
Initialization of the data source failed with following error:
Check the database server or contact your database administrator. Make sure the external database is available, and then try the operation again. If you see this message again, create a new data source to connect to the database.
Cause
You have selected an invalid .cfg file in your Connection string or the .cfg file you have selected has not been updated to support OLE DB.
Sample Problem Code
QueryType=OLEDB
Persist Security Info
Version=1
Connection=Provider=SiebelOLEDB.Provider.1;;Data Source="c:\siebel\client\bin\enu\uagnet.cfg,ServerDataSrc";
CommandType=Default
CommandText= select * from LabRowsetSolution
Check to make sure you have set the
Security Info
parameter in your connection string.Error
The query did not run or the database table could not be opened and you received the following error:
Check the database server or contact your database administrator. Make sure the external database is available and has not been moved or reorganized, then try the operation again.
Cause
The database name in your .cfg file is not set correctly or the name of the table in your query is incorrect.
Sample Problem Code
QueryType=OLEDB
Provider
Version=1
Connection==Siebel OLEDB Provider.1;Persist Security Info=True;Data Source="c:\siebel\client\bin\enu\siebel.cfg,ServerDataSrc";
CommandText
CommandType=Default= select * from LabRowset
Resolution
Check to make sure that the
Provider
parameter is set correctly and also that the table used for theCommandText
is a valid table.Error
SQL Query Analyzer error message. The following error is generated in the SQL Query Analyzer when the Object Manager on the Server is not initialized:
Server: Msg 7399, Level 16, State 1, Line 1
OLE DB provider 'SiebelOLEDB.Provider.1' reported an error. Provider caused a server fault in an external process.Cause
This error typically occurs when Object Manager is not initialized or may be related to SQL Server caching of the OLEDB datasource or to the servers not being successfully restarted.
Sample Problem Code
n/a
Resolution
Restart the servers.
Error
Test connection failed because of an error in initializing provider. 0x80040e73
Cause
Failure to set the DataSource property in the [Siebel] section correctly generates this error when testing the connection. You also get an entry in Windows Event Log regarding this failure.
Sample Problem Code
n/a
Resolution
Check your connection in the Siebel.UDL file and test it by providing the correct username and password. Also in the .cfg file, make sure the
DataSource
property in the[Siebel]
section is set to the correct data source—for example, set to Sample for Sample database.Problem
Receiving "Could not process object select * from GPTest2" error message
Description
If you did not make the custom OLE DB available to the Siebel Server Object Manager, you see the following error when you run the query:
Server: Msg 7357, Level 16, State 2, Line 1. Could not process object 'select * from GPTest2'
Sample Problem Code
n/a
Solution
Make sure that you have copied the latest .srf
to the Server\objects directory and have restarted the server. These actions make the custom OLE DB available to the Siebel Server Object Manager.
Problem
Provider "SiebelOLEDB.Provider.1 supplied inconsistent metadata for a column. Metadata information was changed at execution time"
Description
The length of the columns in the two applications does not match.
Sample Problem Code
n/a
Solution
When SQL Server reports "inconsistent metadata," the user can modify the field length in the rowset definition in Tools.
Problem
Unable to query SODP using MSSQL Query Analyzer
Description
When a connection is established with one type of connection string and then another connection is attempted with a different type of connection string, it fails on the second connection attempt, and generates the following error message:
Error message with MSSQL: OLE DB provider "siebelOLEDB.Provider.1"reported an error. Provider caused a server fault in an external process.
Sample Problem Code
n/a
Solution
Restart the MS SQL Server.