601


ERROR: Memory allocation failure for receive buffer

Description

An attempt to dynamically allocate memory from the operating system using malloc() failed while allocating a buffer to receive network messages.

Action

Ensure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.


602


ERROR: Network access error

Description

There are two possible causes:

  1. A networking error was encountered when sending back a reply message.

  2. The requesting process was running a version of the BEA TUXEDO system more than one release old. Interoperability is supported with only one previous release.

Action

  1. Check for and resolve any networking problems.

  2. Upgrade the BEA TUXEDO system version on the remote machine.


603


ERROR: Memory allocation failure

Description

An attempt to dynamically allocate memory from the operating system using malloc() failed while the tagent was processing a request.

Action

Ensure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.


604


ERROR: Could not decode request message

Description

The tagent process received an invalid request message that it could not decode.

Action

Verify that the correct release of the BEA TUXEDO system is running on both machines. The master machine can be at most one release ahead of other machines in the network.

Contact your BEA TUXEDO system Technical Support.


605


ERROR: Could not set uid/gid for request

Description

The tagent process received a failure from the setgid() or setuid() kernel calls. This indicates that it is not running with the correct login user id or group id.

Action

The tlisten process must be started with a UNIX user id and group id that matches the configuration file. Refer to the UID and GID parameters of the RESOURCES and MACHINES sections.

See Also

ubbconfig(5)


606


ERROR: Invalid version number for request

Description

The tagent process received a request from an incompatible version of the BEA TUXEDO system.

Action

Verify that the correct release of the BEA TUXEDO system is running on both machines. The master machine can be at most one release ahead of other machines in the network.


607


ERROR: Error encoding reply message

Description

A reply message from the tagent process could not be encoded.

Action

Contact your BEA TUXEDO system Technical Support.


609


ERROR: Invalid arguments for opcode

Description

The tagent process received a request message containing invalid argument values.

Action

Contact your BEA TUXEDO system Technical Support.


610


ERROR: Could not creat temp file for TUXCONFIG

Description

The tagent process could not create or write a temporary file for propagation of the configuration file.

Action

Check the directory permissions and free disk space in the system's temporary file directory. The tagent uses UNIX's tmpnam() library function to obtain temporary file names.


611


ERROR: tmloadcf failed when creating new configuration file

Description

The tagent process was attempting to load a new configuration file, and tmloadcf failed.

Action

  • Examine tmboot output for any userlog or error messages.

  • Verify that $TUXDIR/bin/tmloadcf exists and is executable.

  • Verify that the TUXCONFIG file name, directory permissions, and file permissions are set correctly.

  • If the TUXCONFIG file already exists, try removing it and then running tmboot again.

  • If these steps fail, contact your BEA TUXEDO system Technical Support.


612


ERROR: Could not set environment variable

Description

The tagent process encountered an error when attempting to set an environment variable using UNIX's putenv() call.

Action

  • Remove any unnecessary UNIX System environment variables that may have been set when tlisten was started.

  • Expand the UNIX kernel per-process limit for environment variables.


613


ERROR: Could not retrieve parameters from TUXCONFIG file

Description

The tagent process encountered an error when attempting to read an existing TUXCONFIG file.

Action

Contact your BEA TUXEDO system Technical Support.


614


ERROR: Unknown error, terminating

Description

The tagent process encountered an unknown error.

Action

Contact your BEA TUXEDO system Technical Support.


615


INFO: Terminating tlisten process

Description

The tlisten process will print this message in the tlisten log file when terminating. The only valid exit for the tlisten process is when it receives a SIGTERM termination signal.

Action

No action required.

See Also

tlisten(1)


617


ERROR: Invalid tlisten option option

Description

An invalid option, option, was passed to tlisten.

Action

Select the appropriate option(s) from the usage line that follows the message.

See Also

tlisten(1)


624


ERROR: tlisten network address not specified

Description

The user needs to pass the network address where the tlisten process is to listen for connection requests. The address should be passed as an argument to the -l option.

Action

Invoke tlisten with the -l nlsaddr option. The value passed as nlsaddr should be the same as that specified for the NLSADDR parameter in the NETWORK section of the configuration file.

See Also

tlisten(1), ubbconfig(5)


626


ERROR: tlisten could not find entry for user username

Description

The user has the option to reset the user id and group id of the tlisten process through the -u option. If the user id or user name passed as an argument is invalid, the tlisten process will print this message and terminate.

Action

Verify that the argument to the tlisten -u option is a valid user id or user name.

See Also

tlisten(1)


627


ERROR: tlisten cannot run as root

Description

The tlisten process was most likely invoked by root. For security purposes, this is not allowed.

Action

The user should use the -u option to specify an alternate user id or user name instead of root, or invoke the tlisten process from another login.

See Also

tlisten(1)


628


ERROR: tlisten could not set user id to user_name

Description

The tlisten process failed to reset its user id.

Action

Verify that the user name or user id passed as an argument to the -u option has a valid entry in the /etc/passwd file.

See Also

tlisten(1)


629


ERROR: tlisten invoked by non-root, can't change user id.

Description

The user id of the tlisten process may only be changed if the tlisten process was originally invoked by root. When invoked by someone other than root, the user id of the tlisten process may not be reset.

Action

If the user wishes to have the tlisten process run with a specific user id, tlisten should either be invoked by that user, or by root. When invoked by root, the -u option should be used to reset the user id.

See Also

tlisten(1)


636


WARN: Error sending acknowledgment back to requester

Description

The tlisten process was unable to send an acknowledgment back to the requester. The problem associated with this error is not likely to be caused by something that the invoker of the tlisten process will have done. Nor is it likely to be a BEA TUXEDO system error.

Action

Try repeating the same operation. If this fails with the same error, contact your UNIX System administrator or your BEA TUXEDO system Technical Support.

See Also

tlisten(1)


642


ERROR: Invalid service request received, bad message header

Description

The DBBL or BBL process received an invalid service request message. It will be ignored.

Action

Contact your BEA TUXEDO system Technical Support.


644


ERROR: Cannot remove BRIDGE on machine machine

Description

The DBBL process could not remove the bulletin board entry for machine's BRIDGE process.

Action

Contact your BEA TUXEDO system Technical Support.


645


ERROR: Cannot unregister BBL on machine machine

Description

The DBBL process could not remove the bulletin board entry for machine's BBL process.

Action

Contact your BEA TUXEDO system Technical Support.


646


ERROR: Could not restore DBBL entry after temp change for shutdown

Description

The DBBL 's server table entry in the bulletin board had been temporarily modified to allow a partitioned shutdown. The original entry could not be restored.

Action

Contact your BEA TUXEDO system Technical Support.


647


ERROR: Failed to update status of restarting BRIDGE

Description

The local BRIDGE process was marked in the bulletin board as restarting when a new bulletin board upload arrived. This status could not be restored after the upload request was processed.

Action

Contact your BEA TUXEDO system Technical Support.


648


ERROR: DBBL should not receive an O_MIGGRPS opcode

Description

The DBBL process received an internal migration operation code intended for BBLs only. The request will be ignored.

Action

Contact your BEA TUXEDO system Technical Support.


649


ERROR: BBL should not receive an O_UPDGRPS opcode

Description

A BBL process received an internal operation code intended for DBBLs only. The request will be ignored.

Action

Contact your BEA TUXEDO system Technical Support.


650


ERROR: Could not create message queue for temporary DBBL

Description

A temporary DBBL was being created for partitioned shutdown. There was an error when creating its message queue.

Action

Contact your BEA TUXEDO system Technical Support.


651


ERROR: Could not update bulletin board for temporary DBBL

Description

A temporary DBBL was being created for partitioned shutdown. There was an error when updating its server table entry in the bulletin board.

Action

Contact your BEA TUXEDO system Technical Support.


652


ERROR: Could not create message queue for DBBL migration

Description

The DBBL process is migrating to this machine. However, a message queue could not be created for it.

Action

If after the migration the DBBL process is not running on either the master or backup machine, try a partitioned shutdown and reboot of the master. If this does not solve the problem, contact your BEA TUXEDO system Technical Support.

See Also

tmboot(1), tmshutdown(1)


653


ERROR: Could not update DBBL server table entry for migration

Description

The DBBL process is migrating to this machine. However, its new server table entry in the bulletin board could not be updated.

Action

If after this migration the DBBL process is not running on either the master or backup machine, try a partitioned shutdown and reboot of the master. If the error persists, contact your BEA TUXEDO system Technical Support.


654


ERROR: Could not retrieve own bulletin board entry for migration

Description

The DBBL process is migrating to another machine. However, it could not find its own server table entry in the bulletin board. This prevents the old DBBL from broadcasting where the new DBBL is located.

Action

After this migration it is possible that a DBBL process is running on both the master or backup machines. If so, shut down the machine with the newest one (that is, the destination of the last migrate command). Then boot that machine up and try to migrate again. If the error persists, contact your BEA TUXEDO system Technical Support.

See Also

tmboot(1), tmshutdown(1)


655


INFO: Exiting system for migration from mach1 to mach2

Description

The DBBL process has migrated to another machine. The old DBBL outputs this message just before exiting.

Action

No action required.

See Also

tmadmin(1) migrate command


656


ERROR: DBBL should not receive an O_WARMSTART opcode

Description

The DBBL process received an internal operation code intended for BBLs only. The request will be ignored.

Action

Contact your BEA TUXEDO system Technical Support.


657


ERROR: DBBL should not receive an O_LOADTLOG opcode

Description

The DBBL process received an internal operation code intended for BBLs only. The request will be ignored.

Action

Contact your BEA TUXEDO system Technical Support.


662


ERROR: Incompatible TLOG file

Description

The data file being loaded into the TLOG assumes a different maximum number of groups involved per transaction than this BEA TUXEDO system software release allows.

Action

Contact your BEA TUXEDO system Technical Support.


663


INFO: Exiting system

Description

A temporary DBBL that was running to facilitate partitioned shutdown is now exiting.

Action

No action required.


664


ERROR: Service request from process pid failed

Description

A serious failure occurred when processing a service request, and an error response message could not be returned to the originator. Possible causes of the error are: memory allocation failure, software version mismatch, or a shutdown is in progress.

pid is the UNIX System process id number of the requester. However, it might be located on a remote machine.

Action

Contact your BEA TUXEDO system Technical Support.


665


ERROR: Could not unsuspend reconnected node nodename

Description

nodename is a remote machine that had been previously partitioned. It is now back and reconnected to the DBBL. There was a problem unsuspending nodename's services while accepting it back into the network. It will remain partitioned.

Action

On the master machine, perform a tmadmin pclean command for the partitioned node. On the partitioned machine, do a partitioned shutdown and then reboot.

See Also

tmadmin(1), pclean command, tmshutdown(1), tmboot(1)


668


WARN: Stale message received from BBL on machine machinename

Description

During collection of responses to a DBBL broadcast, a stale message (from a previous broadcast) was received from machinename's BBL. The stale message will be ignored.

Action

Check the status of machinename, and its network connections.


669


WARN: Stray string received from process pid

Description

During collection of responses to a DBBL broadcast, an ACK or NACK message was received from an unrecognized process. The ACK/NACK message will be ignored.

Action

No action required.


670


ERROR: Cannot restore message queue, key queuekey

Description

If the DBBL 's UNIX System message queue is ever removed, the DBBL will attempt to recreate it. This should never happen, but the DBBL has recovery code for extra reliability.

This error means the message queue recovery code itself failed. It is a serious error because the DBBL cannot function without a message queue.

Action

Use the UNIX System kill command to force a DBBL restart. If it does not restart successfully within a few minutes, contact your BEA TUXEDO system Technical Support.

See Also

kill(1) in UNIX System reference manuals


672


INFO: Sending BBL on machine name new version of bulletin board

Description

The BBL on machine name is being sent a new copy of the bulletin board by the DBBL. This would occur if a previous bulletin board update request failed, or if machine name had been partitioned and now is reconnected.

Action

No action required.


680


ERROR: Cannot find own table entry

Description

If the DBBL 's UNIX System message queue is ever removed, the DBBL will attempt to recreate it. This should never happen, but the DBBL has recovery code for extra reliability.

This error means the message queue recovery code itself failed. It is a serious error because the DBBL cannot function without a message queue.

Action

Use the UNIX System kill command to force a DBBL restart.

If it does not restart successfully within a few minutes, contact your BEA TUXEDO system Technical Support.


681


ERROR: Cannot update own table entry

Description

If the DBBL 's UNIX System message queue is ever removed, the DBBL will attempt to recreate it. This should never happen, but the DBBL has recovery code for extra reliability.

This error means the message queue recovery code itself failed. It is a serious error because the DBBL cannot function without a message queue.

Action

Use the UNIX System kill command to force a DBBL restart.

If it does not restart successfully within a few minutes, contact your BEA TUXEDO system Technical Support.


682


WARN: New message queue created, key =number

Description

If the DBBL 's UNIX System message queue is ever removed, the DBBL will attempt to recreate it. This should never happen, but the DBBL has recovery code for extra reliability.

This message is output after the DBBL successfully recreates its queue.

Action

No action required.


683


ERROR: Group id for migration is missing

Description

One or more server groups could not be migrated because an internal system message is missing necessary data.

Action

Contact your BEA TUXEDO system Technical Support.


684


ERROR: Memory allocation error

Description

An attempt to dynamically allocate memory from the operating system using malloc() failed while migrating one or more groups.

Action

Ensure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.


685


ERROR: Could not retrieve server entries for migration

Description

One or more server groups could not be migrated because server table entries in the bulletin board could not be retrieved.

Action

Contact your BEA TUXEDO system Technical Support.


686


ERROR: Could not update migrating server's status

Description

A migrating server's status could not be updated in the bulletin board.

Action

Contact your BEA TUXEDO system Technical Support.


687


INFO: Server process marked for migration restart, srvgrp=number srvid=number

Description

The server process has been migrated, and is about to be restarted on the current machine.

Action

No action required.

See Also

tmadmin(1), migrategroup and migratemach commands


688


ERROR: Running server cannot be migrated, srvgrp=number srvid=number

Description

A request was made to migrate this server process. The migration could not proceed because it is still running.

Action

Shut down the process using tmshutdown 's -R option before migrating it.

See Also

tmadmin(1), migrategroup and migratemach commands


692


ERROR: Cannot retrieve BBL entry for pclean operation

Description

When attempting to clean up after a dead or partitioned machine, the DBBL could not find any record of that machine's BBL process.

Action

Contact your BEA TUXEDO system Technical Support.

See Also

tmadmin(1), pclean command


694


ERROR: Cannot lock bulletin board for pclean operation

Description

A bulletin board lock could not be obtained when attempting to clean up after a dead or partitioned machine.

Action

Try again after a few seconds, giving the bulletin board lock recovery algorithm time to run. If this error continues, contact your BEA TUXEDO system Technical Support.

See Also

tmadmin(1), pclean command


695


ERROR: Could not remove server entry for tmid number

Description

When attempting to clean up after a dead or partitioned machine, a server table entry could not be removed from the bulletin board.

Action

Contact your BEA TUXEDO system Technical Support.

See Also

tmadmin(1), pclean command


697


ERROR: Could not access *RESOURCES section of TUXCONFIG file

Description

When attempting to update the version number of the master copy TUXCONFIG file, the RESOURCES section could not be read.

Action

Apparently something has happened to the master machine's TUXCONFIG file. It can be restored by shutting down the entire application, and then running tmloadcf on a backup ASCII copy. Running tmunloadcf on a different machine's TUXCONFIG file should provide a recent backup version.

See Also

tmloadcf(1), tmunloadcf(1)


698


ERROR: Could not read *RESOURCES section of TUXCONFIG file

Description

When attempting to update the version number of the master copy of the TUXCONFIG file, the RESOURCES section could not be read.

Action

Apparently something has happened to the master machine's TUXCONFIG file. It can be restored by shutting down the entire application, and then running tmloadcf on a backup ASCII version. Running tmunloadcf on a different machine's TUXCONFIG file should provide a recent backup version.

See Also

tmloadcf(1), tmunloadcf(1)


699


ERROR: Could not update *GROUPS section of TUXCONFIG file

Description

The location of a server group was being updated in the master copy of the TUXCONFIG file, to reflect a new location after migration. An error prevented the GROUPS section from being read (or updated).

Action

Apparently something has happened to the master machine's TUXCONFIG file. It can be restored by shutting down the entire application, and then running tmloadcf on a backup ASCII version. Running tmunloadcf on a different machine's TUXCONFIG file should provide a recent backup version.

See Also

tmloadcf(1), tmunloadcf(1)