5000


ERROR: Can't get offset for view viewname

Description

Cannot get offset for view, viewname, in routing entry. Possible causes: 1) the view, viewname, is not defined in your environment variable VIEWFILES, 2) it doesn't exist, or 3) the FIELD specified in the routing section is not defined in the view, viewname.

Action

Check your environment variables VIEWFILES and VIEWDIR to see if the view, viewname, is defined. Also, check to see if the view file exists under the VIEWDIR. Then, check the FIELD defined in the DM_ROUTING section of the DMCONFIG file to see if they are indeed defined in the view files.

See Also

dmconfig(5)


5001


ERROR: Can't put FIELDTBLS into environment

Description

The BEA TUXEDO administrative server was unable to reset FIELDTBLS in the process's environment using putenv().

Action

Make the existing environment smaller by unsetting some unneeded variables (or make environment larger if the operating system allows it) and re-execute the program.

See Also

dmconfig(5)


5002


ERROR: Environment variable TUXDIR not defined

Description

The BEA TUXEDO administrative server didn't have TUXDIR set in its environment.

Action

Assign a full pathname (starting at /) to the TUXDIR variable.

See Also

dmconfig(5)


5003


ERROR: Can't put FIELDTBLDIR into environment

Description

The BEA TUXEDO administrative server was unable to reset FLDTBLDIR in the process's environment using putenv().

Action

Make the existing environment smaller by unsetting some unneeded variables (or make environment larger if the operating system allows it) and re-execute the program.

See Also

dmconfig(5)


5004


ERROR: Fldid failed(Ferror=err). Can't find TA_SRVGRP in FIELDTBLS files

Description

The BEA TUXEDO administrative server couldn't find the definition for one of the system fields.

Action

Contact your BEA TUXEDO system Technical Support.

See Also

dmconfig(5)


5005


WARN: pid=pid died leaving SHM locked; cleaning up

Description

A process that was attached to the BB died and holds a user-level semaphore, so the BB is cleaning up.

Action

No action required for BB, but you may want to investigate why the process died.


5006


WARN: Ticket stuck high - retrying

Description

While monitoring the integrity of the Bulletin Board, the BBL found a BEA TUXEDO system user-level semaphore with no owner. In addition, another process was waiting to be served. The BBL must therefore become the owner of the semaphore and delegate it to the waiting process. While trying to do so, the BBL failed to lock the Bulletin Board, and will attempt to lock it again.

Action

No action required.


5007


WARN: Ticket stuck high - retrying

Description

While monitoring the integrity of the Bulletin Board, the BBL found a BEA TUXEDO system user-level semaphore with no owner. In addition, another process was waiting to be served. The BBL must therefore become the owner of the semaphore and delegate it to the waiting process. While trying to do so, the BBL failed to lock the Bulletin Board, and will attempt to lock it again.

Action

No action required.


5008


WARN: Ticket stuck high - resetting

Description

While monitoring the integrity of the Bulletin Board, the BBL found a BEA TUXEDO system user-level semaphore with no owner. In addition, another process was waiting to be served. The BBL must therefore become the owner of the semaphore and delegate it to the waiting process. The BBL managed to lock the Bulletin Board, transfer the ownership of the semaphore, and adjust the statistics.

Action

No action required.


5009


WARN: warning: SHM owned by pid, but not locked

Description

Either the machine does not have proper atomic increment for the user-level semaphore, or there are too many signals coming to the process too quickly.

Action

Contact your BEA TUXEDO system Technical Support.


5010


WARN: SHM lock appears stuck: held by pid=pid

Description

The process has held the lock on the BB for a longer than normal period of time. The process could still be alive, but incorrectly holding the user-level semaphore.

Action

Check the status of the process that is holding the lock. It might be hung, or it is holding the lock for too long a period of time while doing work.


5012


ERROR: Attempted to add a duplicate record with key=key in section section

Description

An attempt to add an entry to a table in shared memory failed because it violated the primary key constraint.

Action

Re-submit the operation with a valid key value for the record.

See Also

dmconfig(5)


5013


ERROR: Can't delete file file in APPDIR used for storing OSITP blob

Description

The GWOSITP process was unable to delete a file it created earlier for storing OSITP BLOB.

Action

Check to make sure that the file still exists. If the file doesn't exist, refrain from deleting files used for saving BLOBS.

See Also

dmconfig(5)


5016


ERROR: Can't open file file in APPDIR for reading OSITP blob

Description

The GWOSITP process was unable to open a file for reading in the APPDIR directory that it created earlier.

Action

Check to make sure that the file still exists. If the file doesn't exist, refrain from deleting files used for saving BLOBS.

See Also

dmconfig(5)


5017


ERROR: Can't read OSITP blob from file file in APPDIR

Description

The GWOSITP process was unable to read a file in the APPDIR directory that it created earlier.

Action

Check to make sure that the file still exists. If the file doesn't exist, refrain from deleting files used for saving BLOBS.

See Also

dmconfig(5)


5018


ERROR: Can't get password entry for RDOM=domain from shmem

Description

When a gateway process establishes a connection with a remote domain, the connecting domain has to pass the security check of the remote domain. If the remote domain is enforcing DM_PW security, then the initiator must have a DM_PASSWORD entry in the BDMCONFIG file corresponding to the remote domain. This message indicates that the password for the remote domain is not available.

Action

Execute the dmadmin program and add a DM_PASSWORD entry for the remote domain, and then re-establish connection with the remote domain.

See Also

dmconfig(5)


5019


ERROR: Can't create more than num segments for a domain

Description

The GWADM server's attempt to create a shared memory segment failed. There is a fixed upper bound for the number of shared memory segments that can be created by a local domain. If this limit is reached, it means that there have been lots of dynamic insertions for this local domain.

Action

By shutting down the application and rebooting it, you can coalesce the shared memory segments.


5020


ERROR: Memory allocation failure

Description

An attempt dynamically to allocate memory from the operating system using malloc failed while attempting to log a transaction. For the most common types of log records, this will result in the transaction being aborted.

Action

Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.


5023


ERROR: Cannot get fieldid for fld

Description

A system error occurred in getting the field identifier when loading the routing entry into the Bulletin Board.

Action

Check the field tables to see if the field specified in the routing table is defined. Also, check your environment variables FLDTBLDIR and FIELDTBLS.

See Also

dmconfig(5)


5024


ERROR: dmroute failed, could not find routing criteria of routing_name for buffer type FML32

Description

A routing_name was specified for a DM_REMOTE_SERVICES entry in the DMCONFIG file that does not appear in the DM_ROUTING section, and the standard FML32 routing function is used (which requires a matching DM_ROUTING entry).

Action

Correct and re-load the DMCONFIG file, or provide an application-specific routing function for FML32 typed buffers.

See Also

dmconfig(5)


5025


ERROR: dmroute failed, could not find routing criteria of routing_name for buffer type FML32

Description

A routing_name was specified for a DM_REMOTE_SERVICES entry in the DMCONFIG file that does not appear in the DM_ROUTING section, and the standard FML32 routing function is used (which requires a matching DM_ROUTING entry).

Action

Correct and re-load the DMCONFIG file, or provide an application-specific routing function for FML32 typed buffers.

See Also

dmconfig(5)


5026


ERROR: Routing field for 'routing_field' null

Description

During data-dependent routing for an FML32 buffer, the specified 'routing_field' value in the FML32 buffer was null.

Action

Make sure the routing field is correctly set in the FML32 buffer.

See Also

dmconfig(5)


5027


ERROR: Field type of buffer does not match routing criteria type

Description

During data-dependent routing of an FML32 typed buffer, the field type for the routing field didn't match the field type for the typed buffers. This should not occur during normal system operation.

Action

Contact your BEA TUXEDO system Technical Support.

See Also

dmconfig(5)


5028


ERROR: unknown field type used for FML32 routing

Description

During data-dependent routing of an FML32 typed buffer, an unknown field type was encountered for the routing field. This should not occur during normal system operation.

Action

Contact your BEA TUXEDO system Technical Support.

See Also

dmconfig(5)


5029


ERROR: Routing field value for 'service' not valid

Description

While doing data-dependent routing on an FML32 typed buffer for the specified service service, the routing field value did not match any of the ranges specified in the routing criteria and the criteria did not contain a wild-card pattern.

Action

Make sure the routing field value is valid. Correct the routing criteria in the RANGES value of the DMCONFIG file.

See Also

dmconfig(5)


5030


ERROR: Can't add REMOTE SECURITY MAP (RDOMSEC) entry into table

Description

The Gateway Administrative server detected an internal error during initialization. An internal function call returned a failure trying to add an entry to the RDOMSEC table in shared memory.

Action

This is an internal error with no associated user action. If the message persists, contact your BEA TUXEDO system Technical Support with the exact error message.

See Also

GWADM(5)


5031


ERROR: Can't add REMOTE USER (RDOMUSR) entry into table

Description

The Gateway Administrative server detected an internal error during initialization. An internal function call returned a failure trying to add an entry to the RDOMUSR table in shared memory.

Action

This is an internal error with no associated user action. If the message persists, contact your BEA TUXEDO system Technical Support with the exact error message.

See Also

GWADM(5)


5037


ERROR: Can't add PRINAPPKEY entry into table

Description

The Gateway Administrative server detected an internal error. An internal function call returned a failure trying to add an entry to the PRINAPPKEY table in shared memory.

Action

This is an internal error with no associated user action. If the message persists, contact your BEA TUXEDO system Technical Support with the exact error message.

See Also

GWADM(5)


5039


ERROR: Can't setup principal-appkey mappings

Description

The Domain Gateway library software detected an error while trying to initialize the Gateway Administrative server. The process was unable to set up the principal-appkey mappings.

Action

This is an internal error with no associated user action. If the error persists, contact your BEA TUXEDO system Technical Support with the exact error message.

See Also

GWADM(5)


5041


ERROR: Can't get VIEW32 offset for view type

Description

The Domain Gateway library software detected an error while trying to initialize the Gateway Administrative server. An internal function call returned an error. The process was unable to get the offset for type.

Action

This is an internal error with no associated user action. If the error persists, contact your BEA TUXEDO system Technical Support with the exact error message.

See Also

GWADM(5)