Skip navigation.

Administration Console Online Help

PreviousNextvertical dots separating previous/next from contents/index/pdfContents

SNMP Gauge Monitors: General

Configuration Options     Related Tasks     Related Topics

Use this page to configure a gauge monitor, which periodically checks the value of an integer or floating-point attribute and generates a trap if the value equals or exceeds a threshold.

Configuration Options

Name Description
Name

The name of this gauge monitor.

Each monitor within a domain must have a unique name.

The name displays in the Administration Console, and if you use WebLogic Server command-line utilities or APIs, you use this name to identify the gauge monitor.

After you have created a gauge monitor, you cannot change its name. Instead, clone the gauge monitor and provide a new name for the clone.

MBean Attribute:
SNMPGaugeMonitorMBean.Name

Changes take effect after you redeploy the module or restart the server.

Monitored MBean Type

The MBean type that defines the attribute you want to monitor. Do not include the MBean suffix. For example, ServerRuntime.

MBean Attribute:
SNMPGaugeMonitorMBean.MonitoredMBeanType

Changes take effect after you redeploy the module or restart the server.

Monitored MBean Name

The name of the MBean instance that you want to monitor. If you leave the name undefined, WebLogic Server monitors all instances of the MBean type that you specify in Monitored MBean Type.

Do not enter the full JMX object name of the MBean instance. Instead, enter only the value of the object name's Name=name name-value pair. To create unique MBean object names, WebLogic Server encodes several name-value pairs into each object name. One of these pairs is Name=name. For example:
"MedRec:Name=MedRecServer,
Type=ServerRuntime"

In the previous example, specify MedRecServer as the name of the MBean instance.

MBean Attribute:
SNMPGaugeMonitorMBean.MonitoredMBeanName

Changes take effect after you redeploy the module or restart the server.

Monitored Attribute Name

The name of an MBean attribute to monitor. This attribute must be in the WebLogic Server MIB.

MBean Attribute:
SNMPGaugeMonitorMBean.MonitoredAttributeName

Changes take effect after you redeploy the module or restart the server.

Polling Interval

The frequency (in seconds) that WebLogic Server checks the attribute value.

MBean Attribute:
SNMPGaugeMonitorMBean.PollingInterval

Minimum value: 1

Maximum value: 65535

Changes take effect after you redeploy the module or restart the server.

Threshold High

The high threshold at which a trap should be generated. A trap is generated if the monitored value is equal to or greater than this value.

MBean Attribute:
SNMPGaugeMonitorMBean.ThresholdHigh

Changes take effect after you redeploy the module or restart the server.

Threshold Low

The low threshold at which a trap should be generated. A trap is generated if the monitored value is less than or equal to this value.

MBean Attribute:
SNMPGaugeMonitorMBean.ThresholdLow

Changes take effect after you redeploy the module or restart the server.

Related Tasks

Related Topics

 

Skip navigation bar   Back to Top