Content starts here

SNMP Subsystem Messages

The SNMP1.0 catalog contains messages in the range BEA320900 - BEA320999. Messages in this catalog are part of the weblogic.management.snmp Internationalization package and the weblogic.i18n Localization package.

BEA-320900

Error: Agent will be unable to proxy for the agents specified due to Proxy initialization error

Description

The SNMP Agent encountered an exceptional conditional while attempting to initialize the configured SNMPProxy entries.

Cause

Refer to exception message for cause of initialization failure.

Action

Take appropriate action based upon the specified exception message.

BEA-320901

Error: The SNMP Agent has received null SNMP PDU for a provided SNMP request.

Description

An attempt to process a given SNMP request has determined that the requestor has provided a null SNMP PDU. Processing of this request cannot continue.

Cause

Invalid SNMP request has been issued.

Action

Verify that utilities being used for SNMP requests are valid.

BEA-320902

Error: Received SNMP PDU with incorrect community name.

Description

An attempt to process a given SNMP request has determined that the specified community name is invalid. Processing of this request cannot continue.

Cause

Invalid community name has been specified on the SNMP request.

Action

Correct community name, to be consistent with that specified on the SNMPAgentMBean configuration, and reissue the request.

BEA-320903

Error: Failed to handle MBean delete Notification for SNMP Configuration MBean.

Description

SNMP Agent configuration processing was unable to correctly handle the configuration update which requested the deletion of existing SNMP configuration.

Cause

Internal processing error while attempting to dynamically modify SNMP configuration.

Action

Take appropriate action based upon the specified exception message. This may require a server restart.

BEA-320904

Error: Unable to determine SNMP Table vector information for this MIB request for class class.

Description

Processing for the specified MIB request was unable to locate the necessary SNMP table vector class needed to correctly return the requested attribute values.

Cause

This is an internal error that could be the result of an invalid MIB entry or missing WebLogic class information.

Action

Contact BEA Support.

BEA-320905

Error: Unable to return requested table vector information for a particular MBean Type for class class.

Description

Processing for the specified MIB request was unable to locate the correct table vector information for the specified MBean Type.

Cause

This is an internal error that could be the result of an invalid MIB entry or missing WebLogic class information.

Action

Contact BEA Support.

BEA-320907

Error: Unable to determine index value for building the correct return table vector for type MBean Type

Description

Processing for the specified MIB request was unable to determine index value for building the correct return table vector for the specified MBean Type.

Cause

This is an internal error that could be the result of an invalid MIB entry or missing WebLogic class information.

Action

Contact BEA Support.

BEA-320908

Error: Unable to set entries field value due to conversion error

Description

Processing for the specified MIB request was unable to determine convert or support the attributes value.

Cause

This is an internal error that could be the result of an invalid MIB entry or mismatch with existing WebLogic MBean information.

Action

Contact BEA Support.

BEA-320909

Error: Error during initialization while attempting to obtain the required DomainRuntimeServer.

Description

An error has occurred during initialization while attempting to obtain the required DomainRuntimeServer, therefore no MBean information will be available. Initialization of the SNMP Agent is terminated.

Cause

This is an internal error.

Action

Contact BEA Support.

BEA-320910

Error: Error during initialization while attempting to obtain required Admin Server RuntimeServer.

Description

An error has occurred during initialization while attempting to obtain the required Admin Server Server RuntimeServer, therefore no MBean information will be available. Initialization of the SNMP Agent is terminated.

Cause

This is an internal error.

Action

Contact BEA Support.

BEA-320911

Error: Configuration error while initializing the set of configured WebLogic Servers that the SNMP Agent will return information for.

Description

Initialization processing encountered a configuration error while initializing the set of configured WebLogic Servers that the SNMP Agent will return information for. Initialization of the SNMP Agent is terminated.

Cause

This could be due to an invalid server configuration entry. Please refer to exception message for more specific cause information.

Action

Take appropriate action based upon the specified exception message.

BEA-320912

Error: Error during initialization while attempting to obtain MBeanServerConnection.

Description

An error has occurred during initialization while attempting to obtain the required MBeanServer connection, therefore no MBean information will be available. Initialization of the SNMP Agent is terminated.

Cause

Please refer to exception message for more specific cause information.

Action

Take appropriate action based upon the specified exception message.

BEA-320913

Error: Failed to register Attribute Change trap for mon of type type on server server

Description

An exception was encountered while attempting to create a JMX Monitor for the specified SNMPAttributeChange trap.

Cause

This may be due to a misconfigured SNMPAttributeChange entry specification in config.xml. Please refer to exception message for more specific cause information.

Action

Modify configuration of the SNMPAttributeChange entry or take appropriate action based upon the specified exception message.

BEA-320914

Error: Failed to add MBeanListener for new instances of type type on server server

Description

A exception was encountered while attempting to create a JMXNotificationListener to detect new MBean instances which would match criteria for the defined SNMPAttributeChange trap.

Cause

This may be due to a misconfigured SNMPAttributeChange entry specification in config.xml. Please refer to exception message for more specific cause information.

Action

Modify configuration of the SNMPAttributeChange entry or take appropriate action based upon the specified exception message.

BEA-320915

Error: Failed to send Attribute Change trap for server server for type type for name name

Description

An exception was encountered while trying to construct and send a SNMP trap for a detected Attribute Change action.

Cause

Please refer to exception message for more specific cause information.

Action

Take appropriate action based upon the specified exception message.

BEA-320916

Error: Unable to handle MBeanServer Notification in AttributeChange Monitor mon for new instance

Description

An exception was encountered while attempting to create a new AttributeChange JMX Monitor for the new instance.

Cause

Please refer to exception message for more specific cause information.

Action

Take appropriate action based upon the specified exception message.

BEA-320917

Error: Unable to add LogNotification Traps at this moment due to unavailiblity of LogBroadcaster Runtime MBean on server server

Description

The required LogBroadcaster Runtime MBean for the specified server was unavailable. Therefore the SNMP Agent is unable to add LogNotification Traps at this moment.

Cause

This is an internal error.

Action

Contact BEA Support.

BEA-320918

Error: Failed to add NotificationListener to logBroadcaster for Server server

Description

An exception occurred while attempting to add a JMX Notification Listener to the LogBroadcasterRuntime MBean. This failure will result in no LogNotification Traps being generated.

Cause

Please refer to exception message for more specific cause information.

Action

Take appropriate action based upon the specified exception message.

BEA-320919

Error: Failed to send Log Notification trap for server server for message msgID for subsystem subSys

Description

An exception was encountered while trying to construct and send a SNMP trap for a detected Log Notification action.

Cause

Please refer to exception message for more specific cause information.

Action

Take appropriate action based upon the specified exception message.

BEA-320920

Error: MBeanServerConnection.createMBean failed for GaugeMonitor mon

Description

Failed to register the requested GaugeMonitor in the MBeanServer.

Cause

There may be a naming conflict with the specified Monitor name.

Action

Query the MBeanServer to determine if the Monitor was successfully registered or already exists.

BEA-320921

Error: MBeanServerConnection.createMBean failed for CounterMonitor mon

Description

Failed to register the requested CounterMonitor in the MBeanServer.

Cause

There may be a naming conflict with the specified Monitor name.

Action

Query the MBeanServer to determine if the Monitor was successfully registered or already exists.

BEA-320922

Error: MBeanServerConnection.createMBean failed for StringMonitor mon

Description

Failed to register the requested StringMonitor in the MBeanServer.

Cause

There may be a naming conflict with the specified Monitor name.

Action

Query the MBeanServer to determine if the Monitor was successfully registered or already exists.

BEA-320923

Error: Failed to register trap for JMX Monitor for mon of type type on server server

Description

An exception was encountered while attempting to create a JMX Monitor for the specified SNMPAttributeChange trap.

Cause

This may be due to a misconfigured SNMPAttributeChange entry specification in config.xml. Please refer to exception message for more specific cause information.

Action

Modify configuration of the SNMPAttributeChange entry or take appropriate action based upon the specified exception message.

BEA-320924

Error: Failed to add MBeanListener for new instances of type type on server server

Description

An exception was encountered while attempting to create a JMXNotificationListener to detect new MBean instances which would match criteria for the defined Monitor Change trap.

Cause

This may be due to a misconfigured SNMPXXXMonitor entry specification in config.xml. Please refer to exception message for more specific cause information.

Action

Modify configuration of the SNMPXXXMonitor entry or take appropriate action based upon the specified exception message.

BEA-320925

Error: Failed to send Monitor trap for server server for type type for object name

Description

An exception was encountered while trying to construct and send a SNMP trap for a detected JMX Monitor action.

Cause

Please refer to exception message for more specific cause information.

Action

Take appropriate action based upon the specified exception message.

BEA-320926

Error: Unable to handle MBeanServer Notification in JMX Monitor Type mon for new instance.

Description

An exception was encountered while attempting to create a new JMX Monitor for the new instance.

Cause

Please refer to exception message for more specific cause information.

Action

Take appropriate action based upon the specified exception message.

BEA-320927

Info: SNMP agent is initializing.

Description

The SNMP agent has begin its initialization process and will process its configuration.

Cause

This message is for informational purposes only.

Action

No action is required.

BEA-320928

Error: SNMP Agent initialization failed while accessing server information for the configured Domain.

Description

The SNMP Agent was not able to successfully complete its initialization due to a failure to process the configured server inforamtion.

Cause

Refer to earlier SNMP error log information for specific information on the cause of the problem.

Action

Take appropriate action based upon the specified exception message.

BEA-320929

Info: SNMP agent initialization complete.

Description

SNMP agent initialization complete. All configuration has been processed and the specified traps and MIB processing is ready.

Cause

This message is for informational purposes only.

Action

No action is required.

BEA-320930

Info: SNMP Agent Generic coldStart trap sent.

Description

As part of its initialization and based upon the specified configured the WebLogic SNMP Agent has created and sent a Generic coldStart trap to the SNMP Manager.

Cause

This message is for informational purposes only.

Action

No action is required.

BEA-320931

Notice: The SNMP trap version is version

Description

The SNMP Agent has been configured to run with the specified SNMP version.

Cause

This message is for informational purposes only.

Action

No action is required.

BEA-320932

Error: SNMPProxy proxy has Value for supportedOIDRoot of oidRoot. It must be an absolute OID beginning with . .

Description

The SNMPProxy has an invalid OID configuration and will be discarded from the configuration.

Cause

Invalid SNMPProxyMBean configuration.

Action

Correct the SNMPProxy config.xml entry.

BEA-320933

Error: SNMP Agent failed initialization due to a configuration exception

Description

An exception was encountered while trying to process the specified SNMP configuration from config.xml.

Cause

This is due to an invalid configuration specification. Please refer to exception message for more specific cause information.

Action

Modify config.xml to correct the invalid configuration entry(s).

BEA-320934

Error: Exceptional condition when checking server status

Description

An exception was encountered while determine the status of the configured WebLogic Server.

Cause

Please refer to exception message for more specific cause information.

Action

Take appropriate action based upon the specified exception message.

BEA-320935

Error: Failed to retrieve attprefix MBean attribute attname for MBean type beanType object name beanName

Description

Processing for the specified MIB request was unable to locate the necessary MBean meta-data needed to correctly return the requested attribute values.

Cause

This is an internal error that could be the result of an invalid MIB entry that does not correspond with the currently supported attrbutes on the specified MBean Type.

Action

Contact BEA Support.

BEA-320936

Error: Unable to determine MBean Information for this MIB request for Type type.

Description

Processing for the specified MIB request was unable to locate the necessary MBean meta-data needed to correctly return the requested attribute values.

Cause

This is an internal error that could be the result of an invalid MIB entry or missing WebLogic class information.

Action

Contact BEA Support.

  Back to Top