You can find the following parameters in the device registry. They are used by the Siebel Handheld application and can be modified. Siebel Client Registry settings are set during the client install. Some of their values can be configured by modifying the setup.ini before installation.

NOTE:  Modifying the registry settings for Siebel Handheld after installation is not recommended. It is recommended that you modify the setup.ini parameters prior to installation instead.

Table 7 describes the Handheld application parameters.

Table 7. Handheld Application Parameters
Parameter
Description

MaxReturnedRecords

(Optional) The maximum number of records returned by an asynchronous query. The default value is 500 records. You may increase or decrease the value by adding the name/value pair through device registry settings. This value is used by SMQ server to set the search result limit. If the number of search result is more than the setting, no records are returned.

SMQPollingInterval

(Optional) Time interval, in seconds, that a Siebel Handheld application contacts a server queue manager to check for messages. The default value is 30 seconds. You may increase or decrease the value by adding this parameter in setup.ini or adding the name/value pair through device registry settings. If you decrease the value, it causes the application to contact the server more often. It means you may get messages faster, but application performance could degrade for non-messaging related operations.

CAUTION:  Change this value only when it is absolutely needed.

SMQRegisterTimeOut

(Optional) Timeout for registration acknowledgement. If the application registration does not happen during the specified time frame, a message box would pop up asking if the user would like to wait longer. The default value is 30 seconds. You can change the default value by adding this parameter in setup.ini or adding the name/value pair through device registry settings. When you are working on a very slow network and find a lot of message boxes popping up before a successful registration, it is recommended you increase the value. Otherwise, you should avoid setting this optional parameter.