Skip navigation.

CMDTUX Messages 1300-1399

  Previous Next

1300

ERROR: Could not generate security password encryption key

Description

An encryption algorithm error occurred while passing security key information to a remote machine.

Action

Contact your BEA TUXEDO system Technical Support.

1301

ERROR: Could not generate security password encryption schedule

Description

An encryption algorithm error occurred while passing security key information to a remote machine.

Action

Contact your BEA TUXEDO system Technical Support.

1302

ERROR: Could not encrypt application security key

Description

An encryption algorithm error occurred while passing security key information to a remote machine.

Action

Contact your BEA TUXEDO system Technical Support.

1307

ERROR: Unable to obtain application password

Description

The tmconfig command was unable to obtain a value for the application password. This value is entered at the terminal if tmconfig is being invoked interactively, and is gotten from the APP_PW environment variable if the standard input to the tmconfig process is not a terminal.

Action

If the tmconfig command is being invoked in the background, be sure to set and export the APP_PW environment variable. If tmconfig is being invoked at a terminal, be sure that the user enters a value at the Enter Application Password: prompt.

See Also

tmconfig(1)

1308

ERROR: Must specify NLSADDR parameters in NETWORK entry machine

Description

The NLSADDR parameter in the NETWORK section of the configuration file must be specified for every machine in the network, except the master machine. It is recommended but not required for the master machine.

Action

Add NLSADDR information to the configuration file.

See Also

ubbconfig(5), NETWORK section

1309

WARN: NLSADDR parameter not specified for NETWORK entry machine

Description

The NLSADDR parameter in the NETWORK section of the configuration file is recommended but not required for the master machine. The master machine needs an NLSADDR and a tlisten process running in order for master migration to work.

Action

Add NLSADDR information for the master machine to the configuration file.

See Also

ubbconfig(5), NETWORK section

1316

ERROR: Can't find the tpadmin field table in dir

Description

While executing tmconfig, the program was unable to get the field identifier for TA_SECTION from the field table $TUXDIR/udataobj/tpadmin.

Action

Make sure that the tpadmin field table exists and is readable. Contact your BEA TUXEDO system Technical Support.

See Also

tmconfig(1)

1317

ERROR: Failed to set group id to administrator

Description

When executing tmboot or tmshutdown as user id 0 (root), the program sets the group identifier to the group identifier for the application administrator as specified in the TUXCONFIG file. The setgid() failed.

Action

Make sure that the v value as set in the RESOURCES or MACHINES sections of the UBBCONFIG file is valid. Contact your BEA TUXEDO system Technical Support.

See Also

tmboot(1), tmshutdown(1)

1318

ERROR: Failed to set user id to administrator

Description

When executing tmboot or tmshutdown as user id 0 (root), the program sets the user identifier to the user identifier for the application administrator as specified in the TUXCONFIG file. The setuid() failed.

Action

Make sure that the UID value as set in the RESOURCES or MACHINES sections of the UBBCONFIG file is valid. Contact your BEA TUXEDO system Technical Support.

See Also

tmboot(1), tmshutdown(1)

1319

INFO: Terminating tlisten process

Description

The tlisten process will print this message to the standard error output when terminating. The only valid exit for the tlisten process is when it receives a SIGTERM termination signal.

Action

No action required.

See Also

tlisten(1)

1320

ERROR: Duplicate -l option specified

Description

While executing tlisten, the -l option was specified more than once on the command line.

Action

Re-execute the command specifying the -l option only once with the network listening address.

See Also

tlisten(1)

1322

ERROR: Duplicate -u option specified

Description

While executing tlisten, the -u option was specified more than once on the command line.

Action

Re-execute the command specifying the -u option only once with the user identifier or name for the configuration administrator.

See Also

tlisten(1)

1326

ERROR: Memory allocation failure

Description

An attempt dynamically to allocate memory from the operating system using malloc() failed while storing a list of processes to be booted or shut down in tmboot or tmshutdown.

Action

Ensure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.

1327

ERROR: Memory allocation failure

Description

An attempt dynamically to allocate memory from the operating system using malloc() failed while generating a list of servers to be booted in tmboot.

Action

Ensure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.

1328

ERROR: Memory allocation failure

Description

An attempt dynamically to allocate memory from the operating system using malloc() failed while generating a list of servers to be shut down in tmshutdown.

Action

Ensure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.

1329

ERROR: Error obtaining Application Password

Description

When the SECURITY option is defined in the UBBCONFIG file, tmloadcf tries to get a password from the user. If the standard input is connected to a terminal, tmloadcf prompts for the password interactively. If not, it looks at the APP_PW environment variable.

This error happens if tmloadcf cannot open the tty device for prompting, or if APP_PW is not set.

Action

If running tmloadcf from a script, make sure that tmloadcf is set and exported into the environment. Otherwise, contact your BEA TUXEDO system Technical Support.

See Also

tmloadcf (1), ubbconfig(5)

1335

ERROR: UID is not effective user ID

Description

While tmloadcf is being run on the master machine, the UID parameter in the RESOURCES or MACHINES section of the UBBCONFIG does not match the effective user identifier of the person running the command.

Action

Change the UID parameter in the RESOURCES or MACHINES section of the UBBCONFIG file or run the command under that user identifier.

See Also

tmloadcf (1)

1336

ERROR: GID is not effective group ID

Description

While tmloadcf is being run on the master machine, the GID parameter in the RESOURCES or MACHINES section of the UBBCONFIG does not match the effective group identifier of the person running the command.

Action

Change the GID parameter in the RESOURCES or MACHINES section of the UBBCONFIG file or run the command under that group identifier.

See Also

tmloadcf (1)

1341

ERROR: MAXACCESSERS parameter must be > 0 and < 32768

Description

The MAXACCESSERS parameter in the MACHINES section of the UBBCONFIG file must be greater than 0 and less than 32768.

Action

Correct the value for MAXACCESSERS as specified in the MACHINES section of the UBBCONFIG file to be greater than 0 and less than 32768.

See Also

tmloadcf (1), ubbconfig(5)

1343

ERROR: MAXGTT parameter must be >= 0 and < 32768

Description

The MAXGTT parameter in the MACHINES section of the UBBCONFIG file must be greater than or equal to 0 and less than 32768.

Action

Correct the value for MAXGTT as specified in the MACHINES section of the UBBCONFIG file to be greater than or equal to 0 and less than 32768.

See Also

tmloadcf (1), ubbconfig(5)

1344

ERROR: MAXCONV parameter must be > 0 and < 32768

Description

The MAXCONV parameter in the MACHINES section of the UBBCONFIG file must be greater than zero and less than 32768.

Action

Correct the value for MAXCONV as specified in the MACHINES section of the UBBCONFIG file to be greater than 0 and less than 32768.

See Also

tmloadcf (1), ubbconfig(5)

1351

ERROR: PERM parameter must be >= 1 and <= 0777

Description

The PERM parameter in the MACHINES section of the UBBCONFIG file must be greater than or equal to 1 and less than or equal to 0777.

Action

Correct the value for PERM as specified in the MACHINES section of the UBBCONFIG file to be greater than or equal to 1 and less than or equal to 0777.

See Also

tmloadcf (1), ubbconfig(5)

1352

ERROR: GROUP entry groupname has TMS specified and LMID lmid does not have TLOGDEVICE

Description

A TMSNAME parameter is specified for group, groupname, but the primary LMID for the group, lmid, does not have a TLOGDEVICE specified in the MACHINES section.

Action

Either change the GROUPS entry to not have a TMSNAME parameter, or change the LMID value for the group, or change the MACHINES entry to have a TLOGDEVICE parameter.

See Also

tmloadcf (1), ubbconfig(5)

1356

ERROR: tpalloc() failed - tperrno_msg

Description

An attempt dynamically to allocate a typed buffer using tpalloc() failed while the DBBL was broadcasting a message to a BBL running the prior release of the software. The message indicates the reason that tpalloc() failed.

Action

Most likely, the call was unable dynamically to allocate memory. Ensure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine. Contact your BEA TUXEDO system Technical Support.

1358

ERROR: Cannot retrieve server information

Description

While executing tmshutdown with the -R option, the program was unable to retrieve the queue information for the servers. The server will be shut down and not migrated to the alternate machine.

Action

Contact your BEA TUXEDO system Technical Support.

See Also

tmshutdown(1)

1359

ERROR: Server ID id in group groupname not marked as restartable. This server will not be restarted upon migration.

Description

While executing tmshutdown with the -R option, the program determined that the server is not configured to be restartable. The server will be shut down and not migrated to the alternate machine.

Action

If you want to be able to migrate the server between the primary and backup machines, the GROUPS entry with which the server is associated must have a primary and backup LMID specified.

See Also

tmshutdown(1), ubbconfig(5)

1360

ERROR: configuration file not found

Description

While executing tmboot or tmshutdown, the program was unable to get the Bulletin Board parameters from the TUXCONFIG configuration file.

Action

Check that the TUXCONFIG environment variable is set and exported. Check the userlog for prior messages that indicate the nature of the failure.

See Also

tmboot(1), tmshutdown(1)

1371

INFO: Connection received from machine

Description

The BRIDGE process has received a connection from another machine, machine.

Action

No action required.

1372

INFO: Orderly disconnect from machine

Description

The BRIDGE process has completed an orderly disconnect sequence with a remote BRIDGE. Orderly disconnections usually result from execution of the tmshutdown utility.

Action

No action required.

See Also

tmshutdown(1) and Messages 1370 and 1371 above.

1373

ERROR: Abnormal disconnect from machine

Description

The BRIDGE process has experienced an abnormal disconnect from a remote BRIDGE. There may be networking problems, or the remote machine may have crashed.

Action

See Also

tmadmin(1)'s reconnect command. Also check Messages 1370, 1371, 1374, 1375, and 1376 in this chapter.

1374

WARN: Reconnecting to machine

Description

The BRIDGE process successfully reconnected to the BRIDGE on machine during recovery from a networking problem.

Action

No action required.

See Also

Message 1373 above

1375

ERROR: Unable to reconnect to machine

Description

The BRIDGE process could not reconnect to machine during recovery from a networking problem.

Action

See Also

Messages 1373 and 1374 above and tmadmin(1)'s reconnect command

1376

WARN: Suspending communication with machine

Description

The BRIDGE process has suspended automatic reconnection attempts to machine for five minutes. This is to prevent thrashing caused by too many recovery attempts.

Action

Use tmadmin(1)'s reconnect command to initiate a reconnection attempt manually. Manual attempts are allowed during the five-minute suspension interval.

See Also

Messages 1373, 1374, and 1375 above and tmadmin(1)'s reconnect command.

1380

ERROR: Message queue blocking prevented delivery, Qaddr = qaddress

Description

The BRIDGE process could not deliver a message it received from the network due to UNIX message queue blocking.

The process(es) associated with the full queue may be identified by looking up qaddress in output of tmadmin 's printserver command (verbose mode).

Another method of examining message queue status is the ipcs -aq command.

Action

See Also

BEA TUXEDO Installation Guide, BEA TUXEDO Administrator's Guide, ipcs(1) in UNIX system reference manuals, tmadmin(1)'s printqueue and printserver commands

1383

WARN: O_IMOK message could not be sent to DBBL, tperrno= tperrno_val

Description

The BBL process experienced a memory allocation failure when attempting to send a message to the DBBL indicating that it is alive and OK. If this happens frequently, the BBL may become partitioned.

Action

Contact your BEA TUXEDO system Technical Support.

See Also

Message 1394 below

1384

WARN: O_IMOK message could not be sent to DBBL, tperrno= tperrno_val

Description

The BBL process experienced a failure when attempting to send a message to the DBBL indicating that it is alive and OK. If this happens frequently, the BBL may become partitioned.

This message is often printed during migration of the DBBL.

Action

If you just migrated the DBBL from master to backup, this message can be ignored. If it continues, it may be necessary to shutdown and reboot the affected machine.

See Also

Message 1394 below

1385

INFO: BBL now unpartitioned, machine= machine

Description

The BBL process on machine was partitioned, and now has rejoined the system. This information will be broadcast to all BBL processes, so that services provided by machine will be available again.

Action

No action required.

See Also

Message 1394 below

1386

ERROR: BBL broadcast send failure, machine= machine tperrno = tperrno_val opcode = 0xnumber

Description

A broadcast message from the DBBL to all unpartitioned BBLs could not be sent. Machines that are not sent the broadcast message will be marked as partitioned.

Action

See Also

Message 1394 below

1387

ERROR: BBL broadcast send timeout, machine= machine opcode = 0xnumber

Description

Broadcast message(s) from the DBBL to all unpartitioned BBL s could not be sent because of a timeout. Machines that are not sent the broadcast message will be marked as partitioned.

Action

See Also

Message 1394 below

1388

ERROR: Cannot get BBL broadcast reply buffer, opcode= 0xnumber

Description

The DBBL could not allocate a buffer for broadcast message replies. All BBLs will be marked as partitioned, since the DBBL does not know the results of the broadcast.

Action

Contact your BEA TUXEDO system Technical Support.

1389

ERROR: Cannot get BBL broadcast replies, tperrno= tperrno_val opcode= 0xnumber

Description

The DBBL encountered an error while trying to receive replies for a broadcast message. All BBLs that have not yet replied will be marked as partitioned.

Action

See Also

Message 1394 below

1390

ERROR: BBL broadcast service failure, machine= machine opcode= 0xnumber

Description

The BBL on machine had a service failure for a broadcast request. It will be marked as partitioned.

Action

See Also

Message 1394 below

1391

ERROR: BBL broadcast RPC failure, machine=machine, opcode=0xnumber

Description

The BBL was unable to process a request from the DBBL. A message will be sent back to the DBBL indicating a problem and requesting a new download of the Bulletin Board.

Action

If the download of the Bulletin Board is successful, no action is required. Otherwise, subsequent userlog messages will indicate further failures or actions to be taken.

1392

ERROR: BBL broadcast reply timeout, machine= machine opcode= 0xnumber

Description

The BBL on machine did not respond to a broadcast message sent by the DBBL within DBBLWAIT * SCANUNIT seconds. As a result, its bulletin board may be out of date, and will be reloaded from the DBBL's copy.

Action

See Also

ubbconfig(5), RESOURCES section

1393

ERROR: BBL upload request not sent, machine= machine tperrno= tperrno_val

Description

An upload request for a new bulletin board could not be sent to the BBL on machine. This BBL will be marked as partitioned.

Action

Contact your BEA TUXEDO system Technical Support.

See Also

Message 1394 below

1394

ERROR: BBL partitioned, machine= machine

Description

The DBBL has determined that the BBL on machine has become partitioned from the master machine, and perhaps from other machines as well. Two likely causes are networking problems or failure of machine. The DBBL will notify all machines it can reach that machine is partitioned. This will prevent additional service requests from being sent to machine.

Action

See Also

tmadmin(1), tmboot(1), Message 1385 above

1395

WARN: Slow BBL response, machine= machine

Description

The BBL on machine sends an I'm OK message to the DBBL every time it performs a sanity check of its machine. This check occurs every SANITYSCAN * SCANUNIT seconds, as specified in the RESOURCES section.

Similarly, every BBLQUERY * SCANUNIT seconds, the DBBL performs a sanity check of all BBLs. If an I'm OK message has not been received from machine during the previous BBLQUERY * SCANUNIT seconds, the DBBL prints this warning message. Then an explicit sanity check is done over the network. If this check also fails, machine will be considered partitioned.

Action

This message indicates that there may be network congestion or an overload on machine. There is a risk that machine will become partitioned.

See Also

Message 1394 above, ubbconfig(5), RESOURCES section

1398

ERROR: TUXDIR environment variable not set

Description

The TUXDIR environment variable was not set. Because of this, the buildclient command will fail.

Action

Set the TUXDIR environment variable to the base directory of the BEA TUXEDO system software, and export this variable.

See Also

buildclient(1)

1399

ERROR: ACUCOBOL environment variable not set

Description

The ACUCOBOL environment variable was not set. Because of this, the buildclient or buildserver command will fail.

Action

Set the ACUCOBOL environment variable to the base directory of the ACUCOBOL-GT system software, and export this variable.

See Also

buildserver(1), buildclient(1)

 

Skip footer navigation  Back to Top Previous Next