Sun Cluster System Administration Guide for Solaris OS

How to Shut Down a Cluster


Caution – Caution –

Do not use send brk on a cluster console to shut down a cluster node. The command is not supported within a cluster.


  1. SPARC: If your cluster is running Oracle Parallel Server or Real Application Clusters, shut down all instances of the database.

    Refer to the Oracle Parallel Server/Real Application Clusters product documentation for shutdown procedures.

  2. Become superuser on any node in the cluster.

  3. Shut down the cluster immediately.

    From a single node in the cluster, type the following command.


    # scshutdown -g0 -y
    

  4. Verify that all nodes are showing the ok prompt on a SPARC based system or a Boot Subsystem on an x86 based system.

    Do not power off any nodes until all cluster nodes are at the ok prompt on a SPARC based system or in a Boot Subsystem on an x86 based system.

  5. If necessary, power off the nodes.

SPARC: Example—Shutting Down a Cluster

The following example shows the console output when stopping normal cluster operation and bringing down all nodes so that the ok prompt is shown. The -g 0 option sets the shutdown grace period to zero, -y provides an automatic yes response to the confirmation question. Shutdown messages also appear on the consoles of the other nodes in the cluster.


# scshutdown -g0 -y
Wed Mar 10 13:47:32 phys-schost-1 cl_runtime: 
WARNING: CMM monitoring disabled.
phys-schost-1# 
INIT: New run level: 0
The system is coming down.  Please wait.
System services are now being stopped.
/etc/rc0.d/K05initrgm: Calling scswitch -S (evacuate)
The system is down.
syncing file systems... done
Program terminated
ok 

x86: Example—Shutting Down a Cluster

The following example shows the console output when stopping normal cluster operation and bringing down all nodes. The -g 0 option sets the shutdown grace period to zero, -y provides an automatic yes response to the confirmation question. Shutdown messages also appear on the consoles of the other nodes in the cluster.


# scshutdown -g0 -y
May  2 10:32:57 phys-schost-1 cl_runtime: 
WARNING: CMM: Monitoring disabled.  
root@phys-schost-1#
INIT: New run level: 0
The system is coming down.  Please wait.
System services are now being stopped.
/etc/rc0.d/K05initrgm: Calling scswitch -S (evacuate)
failfasts already disabled on node 1
Print services already stopped.
May  2 10:33:13 phys-schost-1 syslogd: going down on signal 15
The system is down.
syncing file systems... done
Type any key to continue 

Where to Go From Here