Sun Enterprise 250 Server Owner's Guide

What to Do

  1. Disconnect all cables attached to the power distribution board.

    Start at the top of the board and work your way down.

    1. Disconnect the keyswitch/LED cable at connector J0401.

    2. Disconnect the system interlock cable at connector J0501.

    3. Disconnect the two power sense cables at connectors J0201 and J0202.

    4. Disconnect the DC power cables at connectors J0204, J0205, and J0206.

    5. Disconnect the UltraSCSI power cable at connector J0207.

  2. Loosen the two captive Phillips screws that secure the board to its mounting brackets.

    One screw is located at the top edge, and the other is located at the bottom edge of the power distribution board.

    Figure 9-5  

    Graphic

  3. Remove the board from the chassis, and place it on an antistatic mat.