Sun Enterprise 250 Server Owner's Guide

Solaris prtdiag Command

The prtdiag command is a UNIX shell command used to display system configuration and diagnostic information. You can use the prtdiag command to display:

To run prtdiag, type:


% /usr/platform/sun4u/sbin/prtdiag

To isolate an intermittent failure, it may be helpful to maintain a prtdiag history log. Use prtdiag with the -l (log) option to send output to a log file in /var/adm.


Note -

Refer to the prtdiag man page for additional information.


An example of prtdiag output follows. The exact format of prtdiag output depends on which version of the Solaris operating environment is running on your system.

prtdiag output:


ok /usr/platform/sun4u/sbin/prtdiag -v
System Configuration:  Sun Microsystems  sun4u Sun Ultra Enterprise 250(2 X UltraSPARC-II 248MHz)
System clock frequency: 83 MHz
Memory size: 640 Megabytes

========================= CPUs ========================

Run   Ecache   CPU    CPU
Brd  CPU   Module   MHz     MB    Impl.   Mask
---  ---  -------  -----  ------  ------  ----
SYS     0     0      248     1.0   US-II    1.1
SYS     1     1      248     1.0   US-II    1.1

========================= Memory =========================

Interlv.  Socket   Size
Bank    Group     Name    (MB)  Status
----    -----    ------   ----  ------
  0      none     U0801    32      OK
  0      none     U0701    32      OK
  0      none     U1001    32      OK
  0      none     U0901    32      OK
  1      none     U0802    64      OK
  1      none     U0702    64      OK
  1      none     U1002    64      OK
  1      none     U0902    64      OK
  2      none     U0803    32      OK
  2      none     U0703    32      OK
  2      none     U1003    32      OK
  2      none     U0903    32      OK
  3      none     U0804    32      OK
  3      none     U0704    32      OK
  3      none     U1004    32      OK
  3      none     U0904    32      OK

========================= IO Cards =========================

Bus   Freq
Brd  Type  MHz   Slot  Name                              Model
---  ----  ----  ----  ------------------ ----------------------
SYS   PCI    33     0   SUNW,m64B                         ATY,GT-B              
SYS   PCI    33     1   pciclass,078000                                         
SYS   PCI    33     2   pciclass,078000                                         
SYS   PCI    33     3   glm                               Symbios,53C875        

No failures found in System
===========================

========================= Environmental Status =========================

System Temperatures (Celsius):
------------------------------
      CPU0    44
      CPU1    52
       MB0    32
       MB1    26
       PDB    26
      SCSI    24


=================================
Front Status Panel:
-------------------
Keyswitch position is in On mode.

System LED Status:  DISK ERROR      POWER  
                      [OFF]         [ ON]      
                POWER SUPPLY ERROR  ACTIVITY 
                      [OFF]         [OFF]      
                    GENERAL ERROR   THERMAL ERROR  
                      [OFF]         [OFF]      
=================================
Disk LED Status:	OK = GREEN	ERROR = YELLOW
		DISK  5:    [OK]	DISK  3:    [OK]	DISK  1:    [OK]
		DISK  4:    [OK]	DISK  2:    [OK]	DISK  0:    [OK]

=================================
Fan Bank :
----------

Bank      Speed     Status
         (0-255)	
----      -----     ------
 SYS       140        OK

=================================

Power Supplies:
---------------

Supply     Status
------     ------
  0          OK  

========================= HW Revisions =========================

ASIC Revisions:
---------------
STP2223BGA: Rev 4
STP2003QFP: Rev 1

System PROM revisions:
----------------------
  OBP 3.5.145 1997/10/15 14:50   POST 5.0.5 1997/10/09 16:52