The disk board is hot-pluggable.
Table 10-5 Disk Board Problems
Indication |
Test/Procedure |
Reference |
---|---|---|
System error message or LED code identifies a specific board
|
Locate indicated board. |
LED code must be Off-On-Off. See Table 9-2. |
Check LEDs on board to verify ASR has deactivated the board.
|
|
|
|
Set the SCSI IDs of the replacement drives.
|
|
|
Replace the board or device.
|
See "Hot-Plug Feature". |
|
Note: board is not active until system is booted.
|
|
Board not identified or intermittent problem |
Check /var/adm/messages
|
|
Locate defective SCSI device with probe-scsi-all (OpenBoot command).
|
|
|
|
Check ID jumpers on board.
|
|