Sun Enterprise 6500/5500/4500 Systems Reference Manual

CPU/Memory+ and I/O+ Board LEDs

Table 9-2 summarizes LED codes for boards. The Power, Service, and Cycling symbols are marked on the card cage frame above the respective LEDs. Note that many but not all of the LED codes are the same as the system codes (Table 9-1).

Table 9-2 Board Status LED Codes

Power 

Service 

Cycling  

Condition 

Off 

Off 

Off 

Board has no electrical power. 

Off 

On 

Off 

Board is in low-power mode, can be unplugged. 

Off 

Off 

Flashing 

Undefined. 

Off 

On 

Flashing 

Undefined. 

On 

Off 

Off 

System is hanging, either in POST/OBP or OS.  

On 

Off 

On 

Hung in OS. 

On 

On 

Off 

(Hung in POST/OBP) or (hung in OS and failed component on board). 

On 

On 

On 

(Hung in POST/OBP) or (hung in OS and failed component on board). 

On 

Off 

Flashing 

OS running. System is operating normally.  

On 

On 

Flashing 

OS running and failed component on board.  

On 

Flash 

Off 

Slow flash = POST. Fast flash = OBP.  

On 

Flash 

On 

OS or OBP error.  


Note -

For boards, Off-On-Off indicates that the board is in low-power mode and is ready for removal. (For the system, Off-On-Off indicates a failure.)



Caution - Caution -