Sun Enterprise 6500/5500/4500 Systems Reference Manual

GBICs

Each SBus+ and Graphics+ I/O board has two onboard connectors; each connector accommodates one GBIC (100 MB/sec Fibre Channel).

Removing a GBIC

  1. Locate the GBIC to be removed (Figure 4-23 or Figure 4-24).

    Figure 4-23 SBus+ I/O Board GBIC Connector Locations

    Graphic

    Figure 4-24 Graphics+ I/O Board GBIC Connector Locations

    Graphic

  2. Remove the GBIC from the I/O+ board by compressing the locking tabs located on either side of the card and pulling straight out from the opening in the I/O+ board panel (Figure 4-25).

    Figure 4-25 Removing or Installing a GBIC

    Graphic

Installing a GBIC

  1. Locate the GBIC slot for installation (Figure 4-24).

  2. Ensure correct orientation for insertion.

    The alignment slots should be on the bottom of the GBIC (Figure 4-25).

  3. Insert the GBIC into the I/O+ board panel slot and then push in to firmly seat the card.

    An audible click indicates the GBIC is properly seated to the onboard connector.