This Appendix contains the following specifications for the Sun Fire X2250 server.
A.1 Physical Specifications
TABLE A-1 lists the physical specifications for the Sun Fire X2250 server
TABLE A-1 Sun Fire X2250 Server Physical Specifications
Specification
|
British
|
Metric
|
Height
|
1.75 inches
|
44 mm
|
Width
|
16.75 inches
|
425.5 mm
|
Depth
|
26 inches
|
661 mm
|
Weight
|
21.7 lbs (minimum configuration options)
27.2 lbs (maximum configuration options)
|
9.84 kg
12.34 kg
|
A.2 Power Specifications
Maximum continuous power is 500 W. Other specifications are shown in the following tables.
TABLE A-2 Input Voltage Range
Voltage Ranges
|
Minimum
|
Nominal
|
Maximum
|
Units
|
Range 1
|
90
|
115
|
140
|
Vms
|
Range 2
|
180
|
230
|
264
|
Vms
|
TABLE A-3 Input Frequency
Frequency Ranges
|
Minimum
|
Nominal
|
Maximum
|
Units
|
Range 1
|
57
|
60
|
63
|
Hz
|
Range 2
|
47
|
50
|
53
|
Hz
|
TABLE A-4 AC Input Voltage Rating
Parameter
|
Minimum
|
Rated
|
Maximum
|
Voltage
|
90 Vrms
|
100-240 Vrms
|
264 Vrms
|
Frequency
|
47 Hz
|
50/60 Hz
|
63 Hz
|
TABLE A-5 Input Current
Current Type
|
Values
|
Maximum input current
|
6.3 Amps max @ 100 Vac; 3.0 Amps max @ 240 Vac, full load
|
Maximum measured inrush current
|
34 Amps
|
A.3 Environmental Specifications
Environmental specifications for the Sun Fire X2250 server are shown in TABLE A-6.
TABLE A-6 Sun Fire X2250 Server Environmental Specifications
Specification
|
State
|
British
|
Metric
|
Humidity
|
Operating
|
7%-93% RH non-condensing, 80.6˚ F max wet bulb
|
7%-93% RH non-condensing, 38˚ C max wet bulb
|
|
Nonoperating
|
93% RH, non-condensing, 100.4˚ F max wet bulb
|
93% RH, non-condensing, 43˚ C max wet bulb
|
Vibration
|
Operating
|
0.12 G x-y, 0.17 G z;
5-500 Hz sine
|
|
|
Nonoperating
|
0.3 G x-y, 0.6 G z;
5-500 Hz sine
|
|
Shock
|
Operating
|
4.5 G to 3.5 G;
11 msec. half-sine
|
|
Temperature
|
Operating
|
36˚ F to 100˚ F
|
2˚ C to 35˚ C
|
|
Nonoperating
|
-40˚ F to 154˚ F
|
-40˚ C to 68˚ C
|
Maximum operating temperature derating
|
|
-1.8˚ F for every 985 ft. in altitude
|
-1˚ C for every 300 m in altitude
|
Altitude
|
Operating
|
max 9,843 ft
|
max 3,000 m
|
A.4 Serial Connector Pin Assignments
The serial management port connector is an RS-232-F RJ-45 type connector located on the server back panel.
FIGURE A-1 Serial Management Port Pin Configuration
TABLE A-7 Serial Management Port Pin Assignments
Pin Number
|
Pin Name
|
Description
|
1
|
RTS
|
Ready to send
|
2
|
DTR
|
Data terminal ready
|
3
|
TXD
|
Transmit data
|
4
|
GND
|
Ground
|
5
|
GND
|
Ground
|
6
|
RXD
|
Receive data
|
7
|
DSR
|
Data send ready
|
8
|
CTS
|
Clear to send
|
Sun Fire X2250 Server Service Manual
|
820-4593-12
|
|
Copyright © 2009 Sun Microsystems, Inc. All rights reserved.