0
|
FRU 0 Hot Swap
|
Discrete (0x6f), "Hot Swap" (0xf0)
|
Hot swap for CP3250 FRU
|
N/A
|
1
|
HotSwap AMC 5
|
Discrete (0x6f), "Hot Swap" (0xf0)
|
Hot swap for AMC FRU
|
N/A
|
2
|
HotSwap ARTM 15
|
Discrete (0x6f), "Hot Swap" (0xf0)
|
Hot swap for ARTM FRU
|
N/A
|
3
|
IPMB Physical
|
Discrete (0x6f), "Hot Swap" (0xf0)
|
Link Status of IPMB
|
No reply from IPMB (A or B). State of IPMB A or B bus is reported by monitoring the READY signal on the IPMB isolator.
|
4
|
BMC Watchdog
|
Discrete (0x6f), "Watchdog 2" (0x23)
|
Watchdog state of BMC
|
N/A
|
5
|
12.0V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 12.0V power rail
|
If this voltage is out of spec or goes to zero, all other power rails will fail (Except STBY). Blade server and the RTM will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: All DC/DC converters
|
6
|
5.0V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 5.0V power rail
|
If this voltage is out of spec or goes to zero, most other power rails will fail. Blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Most DC/DC converters
|
7
|
3.3V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 3.3V power rail
|
If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Multiple support devices
|
8
|
3.3V STBY
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 3.3V STBY power rail.
|
If this voltage is out of spec blade server and the H8 will not function. This rail is the power source for the management components on the blade server including all I2C devices and the H8.
|
9
|
SuperCAP voltage
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 3.0V battery (ADM 1026, pin 29)
|
If this voltageis out of limit, the battery has failed or is not installed. Ignore message if not using the battery.
|
10
|
1.2V NTune
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.2V power rail.
|
If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function.
|
11
|
CPU VTT
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of the VTT power rail.
|
If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function.
|
12
|
1.5V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.5V power rail.
|
If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: CPU I/O, DIMMs
|
13
|
1.8 V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.8V power rail.
|
If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function.
|
14
|
DDR2 VTT
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of DDR VTT power rail.
|
If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. Devices: DIMMs
|
15
|
1.05 V Core
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.05V power rail.
|
If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. Devices: CPU
|
16
|
1.5 V NTune
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.5V power rail.
|
If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. Devices: Neptune
|
17
|
VCC CPU1
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of VCC CPU.
|
If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. Devices: CPU
|
18
|
VCC CPU0
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of VCC CPU.
|
If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. Devices: CPU
|
19
|
Inlet 1 Temp Sen
|
Threshold (0x01), "Temperature" (0x01)
|
Ambient Temp, unused
|
N/A. To be deleted in future release.
|
20
|
Inlet 3 Temp Sen
|
Threshold (0x01), "Temperature" (0x01)
|
Ambient Temp, unused
|
N/A. To be deleted in future release.
|
21
|
Inlet 2 Temp Sen
|
Threshold (0x01), "Temperature" (0x01)
|
Ambient Temp, unused
|
N/A. To be deleted in future release.
|
22
|
MCH Temp Sensor
|
Threshold (0x01), "Temperature" (0x01)
|
Junction Temperature, Memory Controller Hub, Northbridge
|
This sensor indicates that the MCH is out of temperature range.
|
23
|
CPU_TEMP_SK0D0
|
Threshold (0x01), "Temperature" (0x01)
|
CPU Junction Temp, socket 0, domain 0
|
This sensor indicates that the CPU is out of temperature range. Above 94C will cause blade server to shutdown.
|
24
|
CPU_TEMP_SK0D1
|
Threshold (0x01), "Temperature" (0x01)
|
CPU Junction Temp, socket 0, domain 1
|
This sensor indicates that the CPU is out of temperature range. Above 94C will cause blade server to shutdown.
|
25
|
CPU_TEMP_SK1DO
|
Threshold (0x01), "Temperature" (0x01)
|
CPU Junction Temp, socket 1, domain 0
|
This sensor indicates that the CPU is out of temperature range. Above 94C will cause blade server to shutdown.
|
26
|
CPU_TEMP_SK1D1
|
Threshold (0x01), "Temperature" (0x01)
|
CPU Junction Temp, socket 1, domain 1
|
This sensor indicates that the CPU is out of temperature range. Above 94C will cause blade server to shutdown.
|
27
|
Version change
|
Discrete (0x6f), "reserved" (0x2b)
|
Firmware update event
|
Reports event after the FW update/cold reset
|
28
|
System Event
|
Discrete (0x6f), "System Event" (0x12)
|
System reset event
|
This sensor reports IPMC reset event to ShMM. This sensor lets NetConsole application know that IPMC has taken a reset and the NetConsole session has to be restarted.
|
29
|
CPU 0 presence
|
Discrete (0x6f), "Entity Presence" (0x25)
|
|
Indicates that CPU0 is installed.
|
30
|
CPU 1 presence
|
Discrete (0x6f), "Entity Presence" (0x25)
|
|
Indicates that CPU1 is installed.
|
31
|
P48V Alarm
|
Discrete (0x70), "OEM reserved" (0xc0)
|
Voltage measurement of 48V power
|
Detects either the 48V power input A or 48V power input B to power module that converts it to 12V.
|
32
|
Sys FW Progress
|
Discrete (0x6f), "System Firmware Progress" (0x0f),
|
Monitors the system firmware progress states.
|
This sensor monitors the firmware progress. The system firmware sends the firmware progress events to the system event log by way of the IPMC.
|
33
|
Graceful Reboot
|
Discrete (0x6f) "OEM reserved" (0xc0)
|
Monitors the state of aa graceful reboot.
|
This sensor logs events into the system event log when a graceful reboot timer starts, stops, or expires.
|