Index

A

AC power supply/fan module, 1U

installing, 1

removing, 1

AC power supply/fan module, 2U

installing, 1

removing, 1

air management sled

installing, 1

auto-assign global spare drive, 1

auto-detect drive swap check time, 1

automatic rebuild, 1

B

battery

expiration information, 1

in-service date

setting, 1

labels, 1

operation, 1

status

critical, 1

degraded, 1

status indicators, 1

battery (SCSI)

replacing, 1

battery module (FC)

replacing, 1

C

chassis FRU (SCSI), installing, 1, 2

chassis FRU replacement

for Sun StorEdge 3510 FC arrays, 1

configuration settings, saving NVRAM configuration settings, 1

controller module (FC)

convert a single controller to dual-controller array, 1

controller module (FC), See I/O controller module

controller module (SCSI)

convert a dual-controller to single controller array, 1, 2

convert a single controller to dual-controller array, 1, 2

dual-controller array replacement, 1, 2

installing, 1, 2

removing, 1, 2

replacing, 1, 2

replacing 4.1x with 3.25, 1

replacing with power off, 1, 2

single-controller array replacement, 1, 2

converting rack-ready to tabletop array, 1

converting tabletop to rack-ready array, 1

D

DC power supply/fan module, 1U

installing, 1

removing, 1

DC power supply/fan module, 2U

installing, 1

removing, 1

disk drives

assigning as spare, 1

defective drives in a JBOD array, 1

defective drives in a RAID array, 1

identifying defective drives, 1

installing, 1

removing defective drives, 1

replacing, 1

scanning, 1

drive swap check time, 1

dual controller RAID array, 1

E

EMU module (SCSI)

installing, 1

removing, 1

replacing, 1

F

fan module, 1U, 1

fan module, 2U, 1

FC JBOD

converting to an FC RAID array, 1

FC RAID array

managing, 1

monitoring, 1

filler panel (SCSI), installing, 1

firmware

upgrade instructions, 1, 2

firmware update

automatic, 1

firmware update (SCSI), 1, 2

flash all But selected drives command, 1

FRUs

installing, 1

FRUs, listing of

for Sun StorEdge 3120 SCSI arrays, 1

for Sun StorEdge 3310 SCSI arrays, 1

for Sun StorEdge 3320 SCSI arrays, 1

for Sun StorEdge 3510 FC arrays, 1

for Sun StorEdge 3511 SATA arrays, 1

G

global spare drive, 1

I

I/O controller module (FC)

convert a dual-controller to single controller array, 1

dual-controller array replacement, 1

installing, 1

removing, 1

replacing, 1

replacing 4.1x with 3.27, 1

SES firmware update, 1, 2

single-controller array replacement, 1

I/O expansion modules (FC)

installing, 1

removing, 1

replacing, 1

I/O modules (SCSI)

installing, 1

installing gaskets, 1

removing, 1

replacing, 1

ID switch module

installing, 1

removing, 1

Identifying SCSI drive command, 1

installing

FRUs, 1

spares, 1

J

JBOD (FC)

convert to a RAID array, 1

JBOD (SCSI)

dual-bus config maintenance, 1

older dual-bus maintenance, 1

using external terminators, 1

L

LED module, 1U

installing, 1

removing, 1

LED module, 2U

installing, 1

removing, 1

logical drive status

REBUILDING, 1

N

NVRAM configuration settings, 1, 2, 3

P

performance problems, 1, 2, 3

power specifications, 1

power supply, 1U, 1

DC, 1

power supply, 2U, 1

AC, 1

DC, 1

power-up sequence, 1

R

REBUILDING, 1

S

saving NVRAM configuration, 1, 2

SFP transceivers

installing, 1

SFPs, installing, 1

show battery status command, 1

show redundancy-mode command, 1

spares

assigning, 1

installing, 1

T

tabletop cover

adding, 1

removing, 1

terminator module (SCSI)

installing, 1

removing, 1

replacing, 1