A P P E N D I X  G

Error Codes and Messages

This appendix provides a list of error codes and status messages for Sun StorEdge Configuration Service. For a list of controller error messages, refer to the Sun StorEdge 3000 Family RAID Firmware User’s Guide.


Error Codes

Shown and described in the Event Log, an error code is an eight-character code that consists of four fields of two characters each. Some codes might be followed by a dash and another eight-character code, which is for internal use only.

The following tables describe the error codes used in each two-character field. The format of the four fields of two characters is:

d1d2d3d4-d5d6d7d8

where

d1 = the Severity Field

d2 = the Major Field

d3 = the Minor Field (determines how d4, d5, d6, d7, and d8 are decoded)


TABLE G-1 Severity Field

Severity Field

Description

01

Critical

02

Warning

03

Informational



TABLE G-2 Major Field

Major Field

Description

01

Unknown

05

 

06

Monitor daemon

08

Server daemon

09

JBOD (Just a bunch of disks) message

0A

Communication

0B

RAID Controller


The Minor field is defined in following table. The definition of the Error Field is dependent upon the definition of the Minor Field in which case the appropriate Table is referenced.


TABLE G-3 Minor Field

Minor Field

Description

01

Unknown

02

See Error Field: System Drive State.

03

See Error Field: Disk State.

04

See Error Field: SAF-TE State.

05

See Error Field: Tape State.

06

See Error Field: Redundancy State.

07

See Error Field: Internal State.

08

See Error Field: Device State.

09

See Error Field: Initialization State.

0A

See Error Field: Invalid Client Parameter.

0B

See Error Field: Open Transport.

0C

See Error Field: Close Transport.

0D

See Error Field: Memory Allocation.

0E

RaidCard fault detected.

10

See Error Field: Transport.

11

See Error Field: Main Communications.

12

See Error Field: Communication Link.

13

See Error Field: Communications Async.

14

See Error Field: Communications Security.

15

See Error Field: Timeout.

16

See Error Field: Administration.

17

See Error Field: Firmware.

18

See Error Field: System Shutdown.

19

Dynamic Growth fault detected.

1C

See Error Field: Set Config.

1D

See Error Field: Controller Event.

1E

See Error Field: Drive Side Event.

1F

See Error Field: Host Side Event.

20

See Error Field: Logical Drive Event.

23

See Server Manage/Monitor Event Error.

2B

See Error Field: Generalized Target Event


Error Field: System Drive State

TABLE G-4 System Drive State Errors

Error Field

 

01

Offline

02

Degraded

03

Online

04

Unknown

05

Parity Check

06

Reconstruction

07

Reconfiguration

08

Dynamic Growth

09

Nonexistent

0A

Initialization


Error Field: Disk State

TABLE G-5 Disk State Errors

Error Field

Description

01

Offline

02

Degraded

03

Online

04

Unknown

05

SMART

06

Dead

07

Statechanged

08

Disklistchanged


Error Field: SAF-TE State

TABLE G-6 SAF-TE State Errors

Error Field

Description

01

Power

02

Fan

03

Thermal

04

Alarm

05

Locked

06

Slot

07

Unknown

08

Unable to get SAF-TE information

09

Battery

0A

Invalid Number of Slots

0B

Environmental Data Not Available

0C

Incompatible revision


Error Field: Tape State

TABLE G-7 Tape State Errors

Error Field

Description

01

Read

02

Write

03

Hard Error

04

Media Error

05

Read Failure

06

Write Failure

07

Media Life

08

Not Upgradable

09

Write Protect

0A

Nonremoval

0B

Cleaning Media

0C

Unsupported Format

0D

Snapped Tape

14

Clean Now

15

Clean Periodic

16

Expired Cleaning Media

1E

Hardware A

1F

Hardware B

20

Interface

21

Eject Media

22

Down Load Fail

28

Loader Hardware A

29

Loader Tray Tape

2A

Loader Hardware B

2B

Loader Door

C8

Query Log Failed

C9

Inquire Tape Failed


Error Field: Redundancy State

TABLE G-8 Redundancy State Errors

Error Field

Description

01

Mode OK

02

No Memory for Negotiation

03

Secondary Failure

04

Secondary Removed

05

Detected Removal of Secondary

06

Detected Insertion of Secondary

07

Primary Failure

08

Primary Removed

09

Detected Removal of Primary

0A

Detected Insertion of Primary

0B

Unknown State

0C

Partner Failed

0D

Partner Inserted

0E

Partner Removed


Error Field: Internal State

TABLE G-9 Internal State Errors

Error Field

Description

01

No Memory

02

Semaphore

03

Thread

04

No Devices


Error Field: Device State

TABLE G-10 Device State Errors

Error Field

Description

01

Inquiry

02

Unknown


Error Field: Initialization State

TABLE G-11 Initialization State Errors

Error Field

Description

01

dll Initializing

02

dll Initializing Failed


Error Field: Invalid Client Parameter

TABLE G-12 Client Parameter Errors

Error Field

Description

01

Set Configuration - Configuration Miscompare

02

Set Configuration - Configuration Device Invalid

03

Set Configuration - Enquire Miscompare

04

Set Configuration - Enquire2 Miscompare

05

Incorrect Application Length

06

Command not Supported

07

Invalid Command

08

Set Configuration - General Miscompare

09

Invalid Length

0A

Invalid Card Identifier

0B

Invalid Card Name

0C

Invalid Parameter

0D

Invalid Command for Card Type

0E

Set Configuration - Invalid Additional Parameter

0F

Set Configuration - Block Overlap

10

Set Configuration - Device Information Invalid


Error Field: Open Transport

TABLE G-13 Open Transport Errors

Error Field

Description

01

Open Transport


Error Field: Close Transport

TABLE G-14 Close Transport Errors

Error Field

Description

01

Close Transport


Error Field: Memory Allocation

TABLE G-15 Memory Allocation Errors

Error Field

Description

01

Insufficient Memory

02

Insufficient Memory for Administration Operation


Error Field: Transport

TABLE G-16 Transport Field Errors

Error Field

Description

01

Lock Fault

02

Insufficient Memory

03

Acquire Lock Fault

04

Release Lock Fault

05

Invalid Command

06

Invalid Length

07

Invalid Card Name

08

Invalid Card Identification

09

No Cards Found

0A

No Devices Found

0B

Open Fault

0C

Card Name not Found


Error Field: Main Communications

TABLE G-17 Main Communications Errors

Error Field

Description

01

Socket Fault

02

Report Fault

03

Thread Fault

04

Lock Fault

05

System Fault


Error Field: Communication Link

TABLE G-18 Communications Link

Error Field

Description

01

Socket Fault


Error Field: Communications Async

TABLE G-19 Communications Async

Error Field

Description

01

Socket Fault

02

Thread Fault

03

Cold Link Fault

04

Send Event Fault


Error Field: Communications Security

TABLE G-20 Communications Security

Error Field

Description

01

Security Violation


Error Field: Timeout

TABLE G-21 Timeout Errors

Error Field

Description

01

Configuration Update

02

Lock Timeout


Error Field: Administration

TABLE G-22 Administration Errors

Error Field

Description

01

Set Customer Name Fault

02

Set Configuration Ended

03

Initialize

04

Initialize Ended

05

Rebuild

06

Rebuild Ended

07

Parity Check

08

Parity Check Ended

09

Set SAF-TE Slot State

0A

Set SAF-TE Perform Slot

0B

Set SAF-TE Send Global

0E

Schedule Parity Check

0F

Schedule Parity Check Ended

10

Set Controller Parameters

11

Firmware Download

12

Consistency Check or Rebuild Ended

13

Controller Reset

14

Expand a Logical Drive

16

Add disk drives to a Logical Drive

18

Copy and replace a disk drive

1A

Background command finished

1B

Background command aborted

1C

Create label for the disks started (only on Solaris)

1D

Create label for the disks finished (only on Solaris)

1E

Media check

1F

Controller shutdown


Error Field: Firmware

TABLE G-23 Firmware Download Errors

Error Field

Description

01

Not a SAF-TE Device

02

Invalid Data Length

03

Download Failed

04

Check Sum Failed

06

Download OK

07

Invalid firmware file

08

Not enough memory

09

Invalid card ID

0A

Controller shutdown failed

0B

Inquiry error

0C

Invalid Product ID

0D

PostDataSet failed

0E

SendDataSection failed

0F

FreeResource error

10

Invalid module ID

11

Invalid download data length

12

Download revision failed

13

Invalid device type


Error Field: System Shutdown

TABLE G-24 System Shutdown Errors

Error Field

Description

01

System Shutdown Failed


Error Field: Set Config

TABLE G-25 Set Config Errors

Error Field

Description

01

Set Configuration Thread creation Failed

02

Get Logical Drive List Command Failed

03

Create Config Command Failed

04

Init Completion Status Command Failed

05

Get Configuration Command Failed

06

Change Volume Config Command Failed

07

Delete Logical Drive Command Failed


Error Field: Controller Event

TABLE G-26 Controller Event Errors

Error Field

Description

01

Controller Reset

02

Controller DRAM Parity Error

03

Redundant Controller Failed

04

Controller Power Supply Failed

05

Controller Fan Failed

06

Controller Temperature Alert

07

Controller UPS AC Power Loss

08

Controller Initialization Complete

09

Controller Power Supply Back Online

0A

Controller Fan Back Online

0B

Controller Temperature Normal

0C

Controller UPS AC Power Back On

0D

Controller RCC SDRAM error

0E

Controller Battery


Error Field: Drive Side Event

TABLE G-27 Drive Side Event Errors

Error Field

Description

01

Drive Channel Select Timeout

02

Drive Channel SCSI Bus Error

03

Drive Channel Unexpected Disconnect

04

Drive Channel Negotiation Error

05

Drive Channel Target Timed Out

06

Drive Channel Parity Error

07

Drive Channel Data Under Or Overrun

08

Drive Channel Undefined Error

09

Drive Channel SCSI Bus Reset Issued

0A

Drive Channel Not Ready Error

0B

Drive Channel Target HW Error

0C

Drive Channel Target Media Error

0D

Drive Channel Unexpected Unit Attention

0E

Drive Channel Unexpected Sense Data

0F

Drive Channel Block Reassign Fail

10

Drive Channel Block Reassign Success

11

Drive Channel SCSI Aborted Command

12

Drive Channel SCSI Channel Fail

13

Drive Channel Smart Fail

14

Drive Channel Scan SCSI Drive


Error Field: Host Side Event

TABLE G-28 Host Side Event Errors

Error Field

Description

01

Host Channel SCSI Bus Reset

02

Host Channel SCSI Bus Device Reset

03

Host Channel Abort Tag Message

04

Host Channel Parity Error

05

Host Channel Reselect Timeout


Error Field: Logical Drive Event


Note - Logical drive event messages often begin with the letters LG, an abbreviation for Logical Group that identifies the logical drive number to which the message applies.



TABLE G-29 Logical Drive Event Errors

Error Field

Description

01

Logical Drive SCSI Drive Fail

02

Logical Drive Initialization Fail

03

Logical Drive Rebuild Fail

04

Logical Drive Initialization Commenced

05

Logical Drive Initialization Completed

06

Logical Drive Rebuild Commenced

07

Logical Drive Rebuild Completed

08

Logical Drive parity check Failed

09

Logical Drive Expand Failed

0A

Logical Drive Add Disk Failed

0B

Logical Drive Parity Check Commenced

0C

Logical Drive Parity Check Completed

0D

Logical Drive Expand Commenced

0E

Logical Drive Expand Completed

0F

Logical Drive Add Disk Commenced

10

Logical Drive Add Disk Completed

11

Logical Drive Add Disk Paused

12

Logical Drive Add Disk Continued

13

Logical Drive Clone Commenced

14

Logical Drive Clone Completed

15

Logical Drive Clone Failed

16

Logical Drive Media Check Commenced

17

Logical Drive Media Check Completed

18

Logical Drive Media Check Continued

19

Logical Drive Media Check Failed

1A

Logical Drive Bad Block Table

1B

Logical Drive Bad Block

1C

Logical Drive Media Scan Bad Block Recovery

1D

Logical Drive Media Scan bad Block Recovered

1E

Logical Drive Parity Event


Error Field: Generalized Target Event

TABLE G-30 Generalized Target Event Errors

Error Field

Description

01

General Power Supply Failure Detected

02

DC Failure Detected

03

AC Failure Detected

04

DC Over Voltage Warning

05

DC Under Voltage Warning

06

DC Over Voltage Critical

07

DC Under Voltage Critical

08

General Power Supply State Change Critical

09

General Power Supply Failure Condition ended

0A

DC Failure Condition ended

0B

AC Failure Condition ended

0C

DC Under Voltage Condition ended

0D

DC Over Voltage Condition ended

0E

Temperature General State Change

0F

General Temperature Alert

10

High Temperature Warning

11

Low Temperature Warning

12

High Temperature Critical

13

Low Temperature Critical

14

General Temperature State Change Critical

15

General Temperature Alert ended

16

High Temperature Condition ended

17

Low Temperature Condition ended

18

Temperature General State Change

19

Fan General Failure Detected

1A

Low RPM Warning

1B

High RPM Warning

1C

Low RPM Critical

1D

High RPM Critical

1E

General Fan State Change Critical

1F

General Fan Failure Condition ended

20

Low RPM condition ended

21

High RPM condition ended

22

General UPS State Change Notification

23

General UPS Failure Detected

24

AC Line Failure Detected

25

DC Line Failure Detected

26

Battery Failure Detected

27

General UPS State Change Critical

28

General UPS Failure condition ended

29

AC Line Failure condition ended

2A

DC Line Failure condition ended

2B

Battery Failure condition ended

2C

General UPS State Change Notification

2D

General Voltage Alert

2E

High Voltage Warning

2F

Low Voltage Warning

30

High Voltage Critical

31

Low Voltage Critical

32

General Voltage State Change Critical

33

General Village Alert ended

34

High Voltage condition ended

35

Low Voltage condition ended

36

General Voltage State Change Notification

37

General Current Alert

38

High Current Warning

39

High Current Critical

3A

General Current State Change Critical

3B

General Current Alert ended

3C

High Current condition ended

3D

General Current State Change Notification

3E

Door is unlocked

3F

General Door State Change Critical

40

Door is now locked

41

General Door State Change Notification


Server Manage/Monitor Event Error

TABLE G-31 Server Manage/Monitor Event Error

Error Field

Description

01

Server to Manage/Monitor has changed.



Error and Status Messages

Most error and status messages are self-explanatory. TABLE G-32 clarifies terms which are used in messages. TABLE G-33 lists the Error/Status messages.


TABLE G-32 Substituted Values

Value

Description

Channel

Card channel number indicating a SCSI channel. A value of 1 indicates the first channel.

Fan

Fan number.

Enclosure

Enclosure number.

LogicalArray

Logical array number.

LogicalDrive

Logical Drive number.

Lun

LUN number.

Name

A text name.

Power

Power supply number.

Slot

Slot number.

State

State of a logical array or a device or an enclosure in text. The values are: Critical, Online, Offline, Critical Rebuild, Non Existent, Low Battery, Normal.

Target

A target or SCSI ID number.

Temperature

The temperature in centigrade.



TABLE G-33 Error/Status Messages

Error and Status Messages

A SCSI Drive Failed (Ch:%d,Id:%d). Replace the defective drive.

A tape has been left in the autoloader by a previous hardware fault. Insert an empty magazine to clear the fault. If the fault does not clear, turn the autoloader off and then on again. If the problem persists, call the tape drive supplier helpline.

A user named ssconfig must be created for configuring SUNWsscs Diag Reporter.

Abort Clone SCSI Drive.

Abort Initialization.

Abort Parity Check.

Abort Rebuild.

Access denied for one or more servers. Log in as ssconfig user, and then try the operation again.

Access denied for one or more servers. Please log in as an ssadmin user and then try the operation again.

Active trap events is empty.

Add Physical drive %d:%d has started on logical drive LogicalDrive.

Add Physical drive has completed on logical drive LogicalDrive.

Add SCSI Drive into Logical Drive information.

Agent Name is empty.

An error occurred while getting data from the server.

An HBA card with this WWN already exists.

Another instance of this program is already running!

Array Admin in Progress.

At least one email address needs to be configured.

Attempted to load a cartridge type, not supported by this drive. The cartridge has been automatically ejected. Attempted to load an unsupported tape format.

Attempted to write to a write-protected cartridge. Remove the write-protection or use another tape.

Audible alarm has an unknown status

Audible alarm has been triggered.

Audible alarm has been turned off.

Background check or rebuild operation in progress.

Background initialization in progress.

Background parity check in progress.

Background rebuild operation in progress.

Battery Expiration Monitoring of (Ch:%d,Id:%d) is not available.

Cannot accept the incoming connection.

Cannot allocate memory.

Cannot bind TCP port with the opened TCP/IP communication.

Cannot connect with the incoming connection.

Cannot create a communication session for the incoming connection.

Cannot create host LUN filter; no host IDs were selected.

Cannot create standard host LUN mapping, no host IDs were selected.

Cannot find the logical drive that was just created. It may have been aborted.

Cannot get configuration from controller. The operation is canceled.

Cannot get configuration in set configuration.

Cannot listen on the opened TCP/IP communication.

Cannot lock a resource.

Cannot open TCP/IP communication.

Cannot perform IOCTL on the TCP/IP communication.

Cannot query incoming data status of the connection.

Cannot receive data from the connected client.

Cannot report status.

Cannot send data to the connected client.

Change logical drive failure.

Change logical volume failure.

Change or set local/global standby drives successful.

Changes made to Optimization will NOT take effect until all the logical drives are deleted and then the controller is RESET.

Click View to select one file.

Close transport fail at set configuration.

Collect mail canceled by user.

Communication is reestablished with controller.

Configuration information saved successfully!

Connect and Login command error

Contact Fax number format is wrong.

Contact Name is empty

Contact Phone number format is wrong.

Continue add drv on logical drive LogicalDrive.

Continue Media Check on Physical Drive %d:%d.

Controller Event, Battery %s %s. Informational message.

Controller Event, Battery %s %s. Likely battery module error or power cycle of array. If error persists, replace defective battery module.

Controller has been reset.

Controller has been shut down.

Controllers back in redundancy mode!

Controllers back in redundancy mode!

Copy & Replace has completed on Physical drive %d:%d.

Copy & Replace has started from Physical drive %d:%d to %d:%d.

Copy & Replace on Physical drive %d:%d has been aborted.

Create logical drive failure.

Create logical volume failure.

Creating Host LUN filter Entry; please wait...

Creating standard Host LUN mapping; please wait...

Customer Fax number format is wrong.

Customer Name is empty.

Customer Phone number format is wrong.

Data is at risk. Media performance of this tape is severely degraded. Copy any data you require from this tape. Do not use this tape again. Restart the operation with a different tape.

Decrypt mail canceled by user.

Delete logical drive failure.

Delete logical volume failure.

Deleted disk successfully!

Deleting disk; please wait...

Deleting Host LUN filter Entry; please wait...

Deleting standard Host LUN mapping; please wait...

Device at [Channel:Target] has failed the self-reliability test.

Device information failed.

Disk(%d.%d) has changed from %s state to %s state.

Disk is labeled successfully.

Door lock has an unknown status.

Door locked.

Door unlocked.

Download Firmware with Boot Record.

Downloading Firmware to the devices

Downloading Firmware to the RAID Controller.

Drive SCSI Ch:%d; Id:%d Likely poorly seated or defective drive. If random drives, possible I/O module or cable failure.

Email address format is wrong.

Enclosure #Enclosure state change: Information: [x}

x is the raw data of SAFTE/SES data in hexadecimal format.

Enclosure #Enclosure, temperature threshold has changed from a State state to a State state. Information:

Engaging firmware; a controller reset is not necessary.

Error in writing file, please try later!

Error occurred. Reset the config file.

Expand LD/LV information.

Expand logical volume successfully.

Expansion has completed on logical drive LogicalDrive.

Expansion has started on logical drive LogicalDrive.

Expansion logical drive LogicalDrive has been aborted.

Fan #Fan has an unknown status.

Fan #Fan is malfunctioning.

Fan #Fan is not present in the system.

Fan #Fan is operational.

File I/O error. Configuration could not be restored!

Firmware downloaded to SAF-TE/SES device (Ch:%d,Id:%d) failed.

Firmware downloaded to SAF-TE/SES device (Ch:%d,Id:%d) successfully.

Firmware downloaded to SCSI drive (Ch:%d,Id:%d) failed.

Firmware downloaded to SCSI drive (Ch:%d,Id:%d) successfully.

First select one Logical Drive!

First select one physical device.

First select one RAID controller.

For RAID1 Logical Drive 'Add Drive'/'Copy and Replace' function is disabled.

Forward mail canceled by user.

Generic File Mutex lock is not released.

Get logical drive list failure.

Getting Agent Options failed!

Getting Controller Parameters failed!

Getting Host LUN Assignments failed! Please try again

Getting the configuration failed!

Group Name can not be empty

Host LUN filter Entry created successfully!

Host LUN filter Entry deleted successfully!

Host LUNs modified successfully.

If file access is not properly coordinated when assigned to multiple hosts, data corruption and access contentions may occur.

If Minimum interval is \“0\” or \“*\”, then Content must be \“Event\”

If the firmware download progress is interrupted the controllers/devices may become unusable.

Initialization has completed on logical drive LogicalDrive.

Initialization has started on logical drive LogicalDrive.

Initialization on logical drive LogicalDrive has been aborted.

Initialization operations have completed.

Initialization, rebuild, expand, or add SCSI drive activities are in progress. Try again later.

Inserted failed primary controller.

Inserted failed secondary controller.

Invalid data received.

Invalid server IP address!

IOM SES Firmware Revision Level Mismatch (LogChl:%d,Id:%d). ses version=%s/%s, pld version=%s/%s. [CHASSIS BKPLN SN#%s}

IP Address format error (must be xxx.xxx.xxx.xxx and 0 < xxx <255) !

IP Address is duplicated!

IP Address is empty.

Location is empty.

Log in as \“ssconfig”\ user and try the operation again.

Logical array LogicalArray has changed from a state state to a state state.

Logical Drive ID %d exceeds 2 TB size limitation for sequential optimized LD.

Logical Drive ID %d exceeds 512 GB size limitation for random optimized LD.

Logical Drive ID %d, Rebuild Aborted. Informational message.

Logical Drive ID LogicalDrive rebuild has aborted.

Logical Drive ID LogicalDrive rebuild has completed.

Logical Drive ID LogicalDrive rebuild has started.

Logical Drive LogicalDrive has changed from a State state to a State state.

Logical Drive LogicalDrive has changed from a State state to a State state.

Logical Volume Components List. Total disks in this Logical Volume=

Login successful

Login unsuccessful

Logout command error.

Mail information is empty

Media Check has completed on Physical drive %d:%d.

Media Check has started on Physical drive %d:%d.

Media Check on Physical drive %d:%d has been aborted.

Memory Allocation Error. Unable to load daemon.

Minimum interval between emails must be one of the following formats: \“*\” \“0\”
“\nn\” \“nn:mm\”

Minimum interval can’t meet Content value.

Minimum interval format error.

Minimum interval format is HH[:MM].

Minimum interval is empty.

Monitor Stopped.

Multiple IP assignment mechanisms are not supported. Select only one mechanism.

Mute beeper.

Mute controller beeper failure.

Mute controller beeper.

Mutex Lock is not released.

Mutex Lock timeouts.

Mutex Lock(s) cannot be created!

Mutex Lock(s) change state failed!

New parity check schedule has been created.

No admin progress exists.

No Admin progress was found. All activity should be complete!

No array administration activity in progress!

No more events to report.

No new controller was found; you do not need to reboot the system.

No online server, cannot delete event log.

No rebuildable drive available.

Only the last partition of a LD/LV can be deleted.

Open transport fail at set configuration.

Open transport, Lock fail, the original lock holder’s IP address is %s.

Open transport, LogIn fail.

Operation completed successfully.

Operation failed.

Operation in progress.

Operation on one of the servers failed.

Out of the scope!

Parity Check Aborted.

Parity check confirmation.

Parity check could not be started on logical drive LogicalDrive.

Parity check has completed on logical drive LogicalDrive.

Parity check has started on logical drive LogicalDrive.

Parity check on logical drive LogicalDrive has been aborted.

Parity check schedule has been removed.

Parity check schedule has been updated.

Partition 0 cannot be deleted.

Partition table is full. New partitions cannot be added.

Password error!

Password is empty.

Port is invalid (port must be between 0 and 65535).

Port is invalid (port must be between 1270 and 1273).

Power supply #Power has an unknown status.

Power supply #Power is malfunctioning and has been switched off.

Power supply #Power is malfunctioning or disabled.

Power supply #Power is not present in the system.

Power supply #Power is operational but disabled.

Power supply #Power is operational.

Power supply #Power is present in the system.

Primary controller failed!

Probe Agent command error!

Progress Not Available.

RAID Controller firmware checksum failed - corrupt firmware data.

RAID Controller firmware download has failed.

RAID Controller firmware has been updated.

RAID Controller is back online.

Read config file error.

Rebuild on logical drive LogicalDrive has been aborted.

Rebuild or check operations have completed.

Redundant Array State Change: Controller Failed.

Redundant Array State Change: Controllers Back in Redundancy Mode.

Removed a failed primary controller.

Removed a failed secondary controller.

Restoring configuration to the controller.

Retry the configuration operation after the update is complete.

SAF-TE/SES card Channel:Target firmware has been updated.

SAF-TE/SES card Channel:Target global status has been updated.

SAF-TE/SES card Channel:Target slot perform status has been updated.

SAF-TE/SES card Channel:Target slot status has been updated.

Save a Copy in server.

Saving configuration information; please wait...

Scan SCSI drive (%d.%d) has succeeded.

Scan SCSI Drive information.

Scheduled parity check could not be started on logical drive LogicalDrive.

Scheduled parity check has completed on logical drive LogicalDrive.

Scheduled parity check has started on logical drive LogicalDrive.

Scheduled parity check skipped to next schedule due to incompletion of previous check.

Secondary controller failed!

Server Error.

Server failed the operation due to insufficient memory.

Server Name is empty.

Server Not managed!

Set controller parameter(s) successful.

Set or add configuration failed.

Slot #Slot has had a device Name.

SMTP From address format is wrong or empty.

SMTP From address format is wrong.

SMTP Server address is empty.

Specify how often you want the parity checked.

Standard Configuration options provide a group of basic default RAID sets whereby the drive size, quantity, and assignments are preconfigured.

Standard Configuration will replace the existing configuration.

Standard Host LUN mapping created successfully!

Standard Host LUN mapping deleted successfully!

Standard maps are available to all connected hosts in certain configurations.

Standby rebuild operation completed with an unknown error.

Standby rebuild operation in progress.

Startup state of the secondary controller.

State Change Mutex lock is not released.

Sun StorEdge Configuration Service monitor daemon has started.

Sun StorEdge Configuration Service server daemon has started.

Sun StorEdge Configuration Service startup is complete.

Sun StorEdge Configuration Service trap daemon has started.

System Administrator (ssconfig) has started irrevocable System Shutdown and Restart. SAVE all data and LOG OFF IMMEDIATELY.

System ID is empty.

Tape operation has stopped because an error occurred while reading or writing data, which the drive cannot correct.

TapeAlert notification. Device [Channel:Target].

Target Media Error Reported (Ch:%d,Id:%d). Likely poorly seated or defective drive. Possible defective drive slot.

Temperature change from TemperatureC to TemperatureC.

The background command (s) has finished.

The background command(s) has been aborted.

The battery on (Ch:%d,Id:%d) is expired on %s. Please install a new battery. Battery Information is (%s).

The battery on (Ch:%d,Id:%d) is going to expire on %s (after %d days). Please install a new battery before the current battery expires. Battery Information is (%s).

The changer mechanism is having difficulty communicating with the tape drive. Turn the autoloader off then on and restart the operation. If the problem persists, call the tape drive supplier helpline.

The configuration has been updated.

The configuration was successfully updated. If new LDs/LVs were created, the server may need to be rebooted.

The Controller devices list changed.

The controller parameters have been updated.

The current user is ssconfig; you cannot log in again.

The daemons are not responding.

The device does not belong to the same HBA card. The operations cannot continue.

The disks list changed.

The drive letter (mounted point) cannot be assigned.

The encrypt key is empty.

The firmware does not support multiple IP assignment mechanisms.

The firmware download failed because you have tried to use the incorrect firmware for this tape drive. Obtain the correct firmware and try again.

The Host LUN filter map (StorEdge SN#%d LD %d Partition %d WWN:) has been created.

The Host LUN filter map (StorEdge SN#%d LD %d Partition %d WWN:) has been deleted.

The in-service date(%s) of new battery on (Ch:%d,Id:%d) is set.

The IP Address cannot be empty.

The last cleaning cartridge used in the tape drive has worn out. Discard the worn out cleaning cartridge, wait for the current operation to finish, and then use a new cleaning cartridge.

The LD# is moved up after you delete the LD, so it may not be consistent with the LD# shown in the RS-232 terminal window.

The length of the Encrypt Key must be greater than 8 characters.

The Mail Server field cannot be empty.

The media has exceeded its specified life.

The memory allocation Failed.

The mount point (drive letter) cannot be written into file (registry).

The new battery on (Ch:%d,Id:%d) is installed. Battery information is (%s).

The number of logical drives did not increase after creating a logical drive. (before:%d now:%d).

The operation failed because the autoloader door is open. Clear any obstructions from the autoloader door, eject the magazine, and then insert it again. If the fault does not clear, turn the autoloader off and then on again.

The operation failed because the tape in the drive has snapped. Discard the old tape. Restart the operation with a different tape.

The Selected Device list is empty!

The server already exists!

The Server Name cannot be empty or only contain any extra spaces.

The server you selected might have already been shut down.

The set configuration failed because there is another conflicting operation.

The set configuration Failed.

The WWN must be a Hex string that is less than 16 characters.

There are no available disks to configure.

There are no LDs/LVs to manage.

There are not enough available disks to add a new LD/LV or there are no available LDs to create a LV. LDs must be unmapped and partitions must be deleted prior to being used in LVs.

There is a map to more than one Host, therefore, the \“Map to Multiple Hosts”\ property cannot be unchecked. Remove the map to multiple hosts before changing this setting.

There is a problem with the autoloader mechanism. Loader mechanism has detected a hardware fault.

There is no spare or replacement drive. Rebuild cannot continue.

This may cause data loss.

This operation can take up to one minute.

This operation might take several seconds. Please wait...

This operation will add to the existing configuration.

This operation will erase any existing configuration and data.

Unable to allocate memory for array inquiry. Unable to monitor this array.

Unable to determine local host, terminating!

Unable to eject cartridge because the tape drive is in use. Wait until the operation is complete before ejecting the cartridge.

Unable to inquire RAID controller.

Unable to inquire SAF-TE device. SAF-TE monitoring for this enclosure disabled.

Unable to inquire tape device. This device will be removed.

Unable to issue Self-Reliability Query on device at [Channel:Target].

Unable to log events.

Unable to open bindings file -or- no bindings present. Check Bindings file.

Unable to open I/O transport layer

Unable to query TapeAlert log data. TapeAlert monitoring disabled for this device.

Unable to read license data.

Unable to read response from SMTP server.

Unable to send e-mail to SMTP server.

Unable to toggle the speaker on the SAF-TE/SES managed enclosure.

Unable to validate recipient at SMTP server.

Unable to write license data.

UNMAPPED LUN, NOT AVAILABLE TO HOST

Username is empty.

Wait for mutex failed.

Write config file error.

Wrong Fax number format.

Wrong Phone number format.

You must first delete the host mapping for the partitions whose index number is greater before you can change this partition.

You must first delete the host mapping for this LD/LV before you can delete it.

You must first delete the host mapping of the last partition before you can add a new partition.

You must have superuser administrator privileges to run this program. exiting...



Installation and Program Prompts

TABLE G-34 contains a list of installation and program prompts.


TABLE G-34 Installation and Program Prompts

Installation and Program Prompts

An existing configuration for this package is found. Do you want to restore it?

Are you sure you want to continue?

Are you sure you want to delete the log file?

Are you sure you want to delete the trap?

Are you sure you want to overwrite the file?

Are you sure you want to rebuild the drive?

Before starting to use SUNWsscsConsole, run /opt/SUNWsscs/sscsconsole/config_sscon to input the pathname of the default Web browser to access HTML help files.

Begin downloading firmware to devices. Do you want to continue?

Cannot find the Java Runtime Environment $JRE_MAJOR.$JRE_MINOR or above! SUNWsscs Console needs JRE 1.2 or above to run. The Console will try to find it in /usr/java, /usr/jre, /usr/local/java, or /usr/local/jre. If you installed the JRE in a directory other than one mentioned above, make a link.

Changes made to this setting will NOT take effect until the controller is RESET. Prior to resetting the controller, the operation may not proceed normally. Do you want to RESET controller?

Click View to select one file.

Do you want to download firmware to the controller?

Do you want to download firmware with boot record to the controller?

Do you want to save the current event log file?

Do you want to set up the mail server?

Enter a Contact Name.

Enter a Customer Name.

Enter a Location.

Enter a mail address.

Enter a System ID.

Enter a valid gateway address.

Enter a valid IP address.

Enter a valid network mask.

Enter SMTP server information.

Enter SMTP Server information.

Enter the login password.

Enter the ssconfig user password to login.

Install JRE 1.2.2, 1.3, or 1.4 before installing the console.

Issue Reset to the controller?

Mapped LUNs exist! These must be deleted before creating new LDs/LVs. If you proceed, this operation overwrites the present configuration. Any existing LDs/LVs are deleted and all data is lost! If you want to keep your present configuration, use the \”Add LDs/LVs to the Current Configuration\” option. Do you want to continue?

Please select a LD/LV!

Please select CH/ID.

Please select the Channel/ID of which you want to scan.

Please specify at least one SSCS agent in command-line or in ssdgrcli.cfg.

Remove the package @PKG_NAME@ and then try to install this package.

Select a LD/LV.

Select a Product ID before downloading firmware.

Select Boot Record File.

Select Configuration File.

Select either AM or PM.

Select Firmware File.

Select only ONE LD/LV!

Select only one row to edit it.

Select only one row to remove it.

Select Server for Managing Controller.

Select the agent before clicking Remove.

Select the agent item before clicking Edit.

Select the Channel/ID of the drive you want to scan

Select the firmware file before downloading it

Select the Logical Drive(s)

Select the server item before clicking Edit.

Select the server item before clicking Remove.

Select the Starting Day.

Specify Map Information.

SUNWsscsConsole needs JRE 1.2.2, 1.3, or 1.4 to run. The Console will try to find it in /usr/java, /usr/jre,/usr/local/java, or /usr/local/jre. If you installed the JRE in a directory other than one mentioned above, make a link.

The client receives events only when it is running. Are you sure you want to exit?

The Content of Periodic Trap cannot be \“Event\”. Please select another one.

The controller needs to be reset for the new firmware to take effect. Do you want to reset the controller?

The encrypt key you entered includes extra space in the beginning or at the end, which can cause encryption errors. Do you want to continue?

This may cause data loss. Are you sure you want to move?

This operation overwrites the present configuration. Any existing LDs/LVs are deleted and all data is lost! If you want to keep your present configuration, use the \“Add LDs/LVs to the Current Configuration\” option. Do you want to continue?

This operation overwrites the present configuration. Any existing LDs/LVs are deleted and all data is lost! If you want to keep your present configuration, use the \“Add LDs/LVs to the Current Configuration”\ option. Do you want to continue?

This operation will result in the loss of data on ALL of the modified partitions. Do you want to continue?

To find out the java version currently installed, type “java-version”

Trap information has been modified. Do you want to save it?

You selected “Event” as the Trap Type, therefore, you must select at lease one Active trap event.

You selected “My SMTP server needs authorization,” therefore, you must enter a Password.

You selected “My SMTP server needs authorization,” therefore, you must enter a Username.

You selected “use encrypt,” therefore, you must enter an encrypt key.