Sun Cluster 3.0-3.1 Hardware Administration Manual for Solaris OS

SPARC: Determining Campus Cluster Interconnect Technologies

This section lists the supported technologies for the private cluster interconnect and the public networks and their various distance limits. You must observe these limits when constructing a campus cluster

SPARC: Cluster Interconnect Technologies

Table 7–2 lists supported node-to-node link technologies and their limitations.

Table 7–2 SPARC: Campus Cluster Interconnect Technologies and Distance Limitations

Link Technology 

Maximum Distance 

100 Mbps Ethernet, unshielded twisted pair (UTP) 

100 meters per segment 

1000 Mbps Ethernet, UTP 

100 meters per segment 

1000 Mbps Ethernet, 62.5/125 micron multimode fiber (MMF) 

260 meters per segment 

1000 Mbps Ethernet, 50/125 micron MMF 

550 meters per segment 

DWDM 

200 kilometers and up 

Always check your vendor documentation for technology-specific requirements and limitations.

SPARC: Storage Area Network Technologies

Table 7–3 lists link technologies for the cluster public network and the distance limits for a single ISL.

Table 7–3 SPARC: Interswitch Link-Length Limits

Link Technology 

Maximum Distance 

Comments 

Fibre-channel (FC) short-wave gigabit interface converter (GBIC) 

500 meters at 1 Gbps 

50/125 micron MMF 

FC long-wave GBIC  

10 kilometers at 1 Gbps 

9/125 micron single-mode fiber (SMF) 

FC short-wave small form-factor pluggable (SFP) 

300 meters at 2 Gbps 

62.5/125 micron MMF 

FC short-wave SFP  

500 meters at 2 Gbps 

62.5/125 micron MMF 

FC long-wave SFP  

10 kilometers at 2 Gbps 

9/125 micron single-mode fiber (SMF)