JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Fire X4640 Server Service Manual     Sun Fire X4640 Server Documentation Library
search filter icon
search icon

Document Information

Using This Documentation

Product Downloads

About This Documentation (PDF and HTML)

We Welcome Your Comments

Change History

Sun Fire X4640 Server Service Manual Overview

Controlling Power and Performing Hardware Reset

About Power Modes

Powering the Server On and Off

Controlling Server Power Remotely

Resetting the Server Using the Reset Switch (SW2)

Removing and Installing Components

Important Safety Information

Antistatic Procedures and Precautions

Tools Required for Servicing the Sun Fire X4640 Server

Preparing the Server for Service and Operation

Removal and Replacement Procedures

List of Customer Replaceable Units and Field Replaceable Units

Identifying Components

Replacing the CMOS Battery (CRU)

Replacing or Adding a Hard Drive (CRU)

Replacing a CPU Module and Filler Card (CRU)

Replacing or Adding DIMMs (CRU)

Replacing or Adding PCI Cards (CRU)

Replacing or Adding a Power Supply (CRU)

Replacing the Fan Tray (CRU)

Replacing the Service Processor Board (FRU)

Replacing the DVD Module (FRU)

Replacing the Power Distribution Board (FRU)

Replacing the Fan Tray Carriage (FRU)

Replacing the Front Panel Indicator Board (FRU)

Replacing the Front I/O Board (FRU)

Replacing a Hard Disk Backplane (FRU)

Replacing the Motherboard (FRU)

Motherboard Connectors and Fasteners

How to Remove the Motherboard

How to Install the Motherboard

Updating Field-Replaceable Unit Information

How To Update Motherboard FRU Information

How to Update CPU Module FRU Information

How to Update the Server CPLDs

Configuring the System Using the BIOS Setup Utilities

BIOS and the BIOS Setup Utility

How to Configure the System BIOS

BIOS Setup Utility Screens

BIOS and Service Processor Updates

LSI BIOS Configuration Utility

Sun Fire X4640 Server References and Specifications

Sun Fire X4640 Server Features and Components

Sun Fire X4640 Server Front and Back Panel Features and Components

Sun Fire X4640 Server Specifications

Sun Fire X4640 Server Motherboard Jumpers and Switches

Sun Fire X4640 Server External LED Locations and Meanings

Locating the Sun Fire X4640 Server System Serial Number

Index

How to Install the Motherboard

  1. If necessary, perform the steps to remove the old motherboard. See How to Remove the Motherboard.
  2. Ensure that the mylar insulation is in the chassis and that it is correctly installed.

    The mylar insulation should lie flat. It is stamped to fit within the chassis and uses the standoff and support pegs for alignment.


    Caution

    Caution - Potential for component damage. Do not install the motherboard without the mylar insulation in place.


  3. Carefully lower the new motherboard into the chassis with the rear of the motherboard tilted downward.
  4. Insert the motherboard power tab into the opening in the chassis midwall.
  5. Insert the light pipes and connectors on the motherboard into the corresponding holes in the chassis back panel.
  6. Lower the front of the motherboard, using care to align the corresponding holes in the motherboard over the six bus-bar bolts.
    image:An illustration showing how to position the motherboard within the server chassis.
  7. Lower the small metal door in the chassis midwall that closes over the motherboard power tab.

    When you slide the door down, first push outward on the door’s handle to free it from the tab in the chassis midwall. This door must be closed to ensure proper air circulation and cooling.


    image:An illustration showing how to close the small door in the chassis midwall.
  8. Secure the motherboard to the power bus bars using the six screws.

    Torque screws to 7 inch-pounds (0.8 newton meters).

  9. Tighten the five captive screws that secure the motherboard to the chassis.

    Torque screws to 7 inch-pounds (0.8 newton meters).

  10. Connect the flex cable to the motherboard connector.
  11. Connect the front indicator board flex cable to the motherboard flex cable connector.
    image:An illustration showing how to connect the font panel-to-MB flex cable.
  12. To install the rear CPU module guide, align the edges of the guide with the metal edge-guides in the chassis, then lower the guide until it is seated firmly against the motherboard.

    When you install the guide, be sure to align it so that the interlock switch lever is over the interlock switch on the motherboard.

  13. To secure the guide to the motherboard and chassis, tighten the six captive screws.
    image:An illustration showing the installation of the CPU module guide.
  14. Install the fan tray carriage. See How to Install the Fan Tray Carriage.
  15. Install any PCI cards. See How to Install a PCI Card.
  16. Install the CPU modules and filler cards. See How to Install a CPU Module or Filler Card.
  17. Prepare the server for operation. See How to Prepare the Server for Operation.
  18. Update the motherboard FRU information. See Updating Field-Replaceable Unit Information.
  19. Update the system with the BIOS/ILOM firmware package you downloaded earlier. See the “Before You Begin” section in How to Remove the Motherboard.

    This will ensure that both the BIOS and ILOM firmware (which are packaged and tested together) are at a supported level.

    For information about updating firmware, see Updating Firmware in Sun ILOM 3.0 Supplement for the Sun Fire X4640 Server.