Skip Navigation Links | |
Exit Print View | |
Sun Fire X4640 Server Service Manual Sun Fire X4640 Server Documentation Library |
About This Documentation (PDF and HTML)
Sun Fire X4640 Server Service Manual Overview
Controlling Power and Performing Hardware Reset
Powering the Server On and Off
Controlling Server Power Remotely
Resetting the Server Using the Reset Switch (SW2)
Removing and Installing Components
Antistatic Procedures and Precautions
Tools Required for Servicing the Sun Fire X4640 Server
Preparing the Server for Service and Operation
Removal and Replacement Procedures
List of Customer Replaceable Units and Field Replaceable Units
Replacing the CMOS Battery (CRU)
Replacing or Adding a Hard Drive (CRU)
Replacing a CPU Module and Filler Card (CRU)
How to Remove a CPU Module or Filler Card
CPU Module Slot Designations and Population Rules
How to Install a CPU Module or Filler Card
Replacing or Adding DIMMs (CRU)
Replacing or Adding PCI Cards (CRU)
Replacing or Adding a Power Supply (CRU)
Replacing the Service Processor Board (FRU)
Replacing the DVD Module (FRU)
Replacing the Power Distribution Board (FRU)
Replacing the Fan Tray Carriage (FRU)
Replacing the Front Panel Indicator Board (FRU)
Replacing the Front I/O Board (FRU)
Replacing a Hard Disk Backplane (FRU)
Replacing the Motherboard (FRU)
Updating Field-Replaceable Unit Information
How to Update the Server CPLDs
Configuring the System Using the BIOS Setup Utilities
BIOS and the BIOS Setup Utility
How to Configure the System BIOS
BIOS and Service Processor Updates
LSI BIOS Configuration Utility
Sun Fire X4640 Server References and Specifications
Sun Fire X4640 Server Features and Components
Sun Fire X4640 Server Front and Back Panel Features and Components
Sun Fire X4640 Server Specifications
Sun Fire X4640 Server Motherboard Jumpers and Switches
Sun Fire X4640 Server External LED Locations and Meanings
The CPU module for the Sun Fire X4640 server has a mechanical key located on the upper right side of the module. This key renders the module unique to the Sun Fire X4640 server, and prevents the module from being installed in Sun Fire X4600 and X4600 M2 servers, which use a similar type card. The CPU module for the X4640 server is not compatible with X4600 and X4600 M2 servers. Do not remove the mechanical key and attempt to install the module in a different model of server. Conversely, CPU modules for the X4600 and X4600 M2 servers are not compatible with the X4640 server. Do not attempt to install an X4600 and X4600 M2 CPU module in an X4640 server. The following illustration shows the features and components of the CPU module.
|