Sun Cluster Data Service for Informix Guide for Solaris OS

Probing Algorithm and Functionality

Sun Cluster HA for Informix fault monitor is controlled by the extension properties that control the probing frequency. The default values of these properties determine the preset behavior of the fault monitor. The preset behavior should be suitable for most Sun Cluster installations. Therefore, you should tune the Sun Cluster HA for Informix fault monitor only if you need to modify this preset behavior. You can modify this behavior by performing the following actions:

The Sun Cluster HA for Informix fault monitor checks the database within an infinite loop. During each cycle the fault monitor checks the database state and reports either a failure or success.

If the fault monitor is successful, it returns to its infinite loop and continues the next cycle of probing and sleeping.

If the fault monitor reports a failure, a request is made to the cluster to restart the resource. If the fault monitor reports another failure, another request is made to the cluster to restart the resource. This behavior continues whenever the fault monitor reports a failure.

If successive restarts exceed the Retry_count within the Thorough_probe_interval, a request is made to fail over the resource group onto a different node or zone.