SPARC T3-1B Server Module Topic Set
search filter icon
search icon

Document Information

Using This Documentation

Product Notes

Related Documentation

Feedback

Support and Accessibility

Installation

Planning the Installation

Shipping Kit Inventory List

Features

Specifications

Site Planning

Preinstalled Software

Front and Rear Panel Components

Server Module Cabling

Plan Communication With the Server Module During Installation

Installing the Server Module

Handling Precautions

ESD Precautions

Tools Needed for Installation

Optional Component Installation

Modular System Chassis Preparation

Insert the Server Module Into the Chassis

Communicating With the Server Module During Startup

Monitor the Diagnostic Messages

Powering On the Server Module for the First Time

Initial Power-On Task Overview

Power On the System for the First Time

Configure the System

Install Oracle Solaris Software From the Network

Oracle Solaris Configuration Settings

Assign a Static IP Address to the Service Processor

Administration

Understanding System Administration Resources

Oracle ILOM Overview

Platform-Specific Oracle ILOM Features

Oracle Solaris OS Overview

OpenBoot Overview

Oracle VM Server for SPARC Overview

Multipathing Software

Hardware Management Pack Overview

Source for Downloading Hardware Management Pack Software

Hardware Management Pack Documentation

Accessing the Server

Log In to Oracle ILOM

Log In to the System Console

Display the ok Prompt

Display the Oracle ILOM -> Prompt

Use a Local Graphics Monitor

Oracle ILOM Remote Console

Controlling the Server

Power On the Server

Power Off the Server

Reset the Server From the Oracle Solaris OS

Reset the Server From Oracle ILOM

Reset the SP to Default Values

Configuring Hardware RAID

Hardware RAID Support

Important Hardware RAID Guidelines

Disk Zones for SPARC T3-1 Servers With Sixteen-Disk Backplanes

Displaying Disk Zone Information

Enabling and Disabling Disk Zoning In the Field

Prepare to Use the FCode Utility

FCode Utility Commands

Create a Hardware RAID Volume

Hot Spare Drives in RAID Volumes (LSI)

Determining If a Drive Has Failed

RAID Drive Replacement Strategies

Locate Device Paths

Changing Server Identification Information

Change Customer FRUdata Information

Change System Identifier Information

Configuring Policy Settings

Specify Cooldown Mode

Restore Host Power State at Restart

Specify Host Power State at Restart

Disable or Re-Enable Power-On Delay

Specify Parallel Boot of the SP and Host

Configure Host Behavior With the Keyswitch State

Configuring Network Addresses

SP Network Address Options

Disable or Re-Enable Network Access to the SP

Display the DHCP Server IP Address

Display the Host MAC Address

Using an In-band Connection to the SP

Configuring Boot Mode

Boot Mode Overview

Configure the Host Boot Mode of Oracle VM Server for SPARC

Change the Host Boot Mode Behavior at Reset

Manage the Host Boot Mode Script

Display Host Boot Mode Expiration Date

Override OpenBoot PROM Settings to Reset the Server

Configuring Server Behavior at Restart

Specify Behavior When the Host Resets

Specify Behavior When the Host Stops Running

Set the Boot Timeout Interval

Specify Behavior at Boot Timeout

Specify Behavior if Restart Fails

Specify Maximum Restart Attempts

Configuring Devices

Unconfigure a Device Manually

Reconfigure a Device Manually

Monitoring the Server

Monitoring Faults

Enabling Automatic System Recovery

Display Server Components

Locate the Server

Updating the Firmware

Display the Firmware Version

Update the Firmware

Display OpenBoot Version

Display POST Version

Identifying WWN-Designated SAS2 Devices

World Wide Name Syntax

probe-scsi-all Output Example (SPARC T3-1, Eight-Disk Backplane)

probe-scsi-all Output Example (SPARC T3-1, Sixteen-Disk Backplane)

probe-scsi-all Output Example (SPARC T3-4)

Identify a Disk Slot Using probe-scsi-all (OBP)

Identify a Disk Slot Using prtconf (Oracle Solaris, Onboard Controllers)

Identify a Disk Slot Using prtconf (Oracle Solaris, Single Initiator)

WWN Syntax in an OS Installation on a Specific Device

WWN Syntax in an OS Installation on a RAID Volume

Service

Identifying Components

Front and Rear Panel Components

Illustrated Parts Breakdown

Detecting and Managing Faults

Diagnostics Overview

Diagnostics Process

Diagnostics LEDs

Managing Faults (Oracle ILOM)

Interpreting Log Files and System Messages

Managing Faults (Oracle Solaris PSH)

Managing Faults (POST)

Managing Components (ASR Commands)

Checking if Oracle VTS Software Is Installed

Preparing for Service

General Safety Information

Tools Needed for Service

Find the Modular System Serial Number

Find the Server Module Serial Number

Locate the Server Module

Removing the Server Module From the Modular System for Service

Servicing Hard Drives

Drive Hot-Plugging Rules

Remove a Drive

Replace or Add a Drive

Remove a Drive Filler

Install a Drive Filler

Servicing Memory

Memory Faults

Locate a Faulty DIMM (LEDs)

Remove a DIMM

Install a Replacement DIMM

Clear the Fault and Verify the Functionality of the Replacement DIMM

Verify DIMM Functionality

DIMM Configuration Reference

Servicing a REM

Remove a REM

Install a REM

Servicing a FEM

Remove a FEM

Install a FEM

Servicing a Service Processor Card

Remove the Service Processor Card

Install the Service Processor Card

Servicing the ID PROM

Remove the ID PROM

Install the ID PROM

Verify the ID PROM

Servicing a USB Flash Drive

Remove a USB Flash Drive

Install a USB Flash Drive

Servicing the Battery

Replace the Battery

Replacing the Server Module Enclosure Assembly

Transfer Components to Another Enclosure Assembly

Returning the Server Module to Operation

Replace the Cover

Install the Server Module Into the Modular System

Start the Server Module Host

Glossary

Index

probe-scsi-all Output Example (SPARC T3-1, Sixteen-Disk Backplane)

When analyzing probe-scsi-all output, look for this SAS device information:

The following table shows the PhyNum-to-disk slot correspondence for a sixteen-disk backplane connected to onboard SAS controllers 0 and 1.


Note - The default 16-disk backplane configuration is divided into two logically isolated zones, with disk slots 0-7 visible to SAS controller 0 and disk slots 8-15 visible to SAS controller 1.


Table 4 SAS Controller Port Mapping for Sixteen-Disk Backplanes  

SAS Controller
PhyNum

(Hex)

Disk Slot

(Dec)

SAS Controller
PhyNum

(Hex)

Disk Slot

(Dec)

0
0
0
1
8
8
1
1
9
9
2
2
A
10
3
3
B
11
4
4
C
12
5
5
D
13
6
6
E
14
7
7
F
15

The following example illustrates probe-scsi-all output for a SPARC T3-1 server with nine hard drives in a sixteen-disk capable backplane configuration.


Note - Controller 1 manages the SATA DVD.


The default boot location (physical slot 0) is listed as PhyNum 0 in the SAS controller 0 section. It has a SASDeviceName value of 5000cca00a59278c and a SASAddress value of 5000cca00a59278d.

ok probe-scsi-all
/pci@400/pci@2/pci@0/pci@f/pci@0/usb@0,2/hub@2/hub@3/storage@2
   Unit 0   Removable Read Only device    AMI     Virtual CDROM   1.00
 
/pci@400/pci@2/pci@0/pci@4/scsi@0          <---- SAS controller 1
 
FCode Version 1.00.54, MPT Version 2.00, Firmware Version 5.00.17.00
 
Target a
  Unit 0   Disk   HITACHI  H103030SCSUN300G A2A8    585937500 Blocks, 300 GB
  SASDeviceName 5000cca00a746490  SASAddress 5000cca00a746491  PhyNum 8
Target b
  Unit 0   Disk   SEAGATE  ST930003SSUN300G 0B70    585937500 Blocks, 300 GB
  SASDeviceName 5000c5001d0d1283  SASAddress 5000c5001d0d1281  PhyNum 9
Target c 
  Unit 0   Disk   HITACHI  H103030SCSUN300G A2A8    585937500 Blocks, 300 GB
  SASDeviceName 5000cca00a01014c  SASAddress 5000cca00a01014d  PhyNum a
Target d
  Unit 0   Disk   SEAGATE  ST930003SSUN300G 0B70    585937500 Blocks, 300 GB
  SASDeviceName 5000c5001d0ca947  SASAddress 5000c5001d0ca945  PhyNum b
Target e
  Unit 0   Disk   SEAGATE  ST930003SSUN300G 0B70    585937500 Blocks, 300 GB
  SASDeviceName 5000c5001d0d2857  SASAddress 5000c5001d0d2855  PhyNum cTarget f
  Unit 0   Disk   HITACHI  H103030SCSUN300G A2A8    585937500 Blocks, 300 GB
  SASDeviceName 5000cca00a02f5d0  SASAddress 5000cca00a02f5d1  PhyNum d
Target 10
  Unit 0   Disk   SEAGATE  ST930003SSUN300G 0B70    585937500 Blocks, 300 GB
  SASDeviceName 5000c5001d0c3d9b  SASAddress 5000c5001d0c3d99  PhyNum e
Target 11
  Unit 0   Disk   SEAGATE  ST930003SSUN300G 0B70    585937500 Blocks, 300 GB
  SASDeviceName 5000c5001d097737  SASAddress 5000c5001d097735  PhyNum f
Target 12
  Unit 0   Encl Serv device   SUN      SAS2 X16DBP      0305
  SASAddress 50800200000272bd  PhyNum 18
 
/pci@400/pci@1/pci@0/pci@4/scsi@0          <---- SAS controller 0
 
FCode Version 1.00.54, MPT Version 2.00, Firmware Version 5.00.17.00
 
Target a
  Unit 0   Disk   HITACHI  H103030SCSUN300G A2A8    585937500 Blocks, 300 GB
  SASDeviceName 5000cca00a59278c  SASAddress 5000cca00a59278d  PhyNum 0
Target b
  Unit 0   Disk   SEAGATE  ST930003SSUN300G 0768    585937500 Blocks, 300 GB
  SASDeviceName 5000c50017c7e6fb  SASAddress 5000c50017c7e6f9  PhyNum 1
Target c
  Unit 0   Disk   HITACHI  H103030SCSUN300G A2A8    585937500 Blocks, 300 GB
  SASDeviceName 5000cca00a4bfcb8  SASAddress 5000cca00a4bfcb9  PhyNum 2
Target d
  Unit 0   Disk   SEAGATE  ST930003SSUN300G 0768    585937500 Blocks, 300 GB
  SASDeviceName 5000c50017c7a3a3  SASAddress 5000c50017c7a3a1  PhyNum 3
Target e
  Unit 0   Disk   HITACHI  H103030SCSUN300G A2A8    585937500 Blocks, 300 GB
  SASDeviceName 5000cca00a02cc18  SASAddress 5000cca00a02cc19  PhyNum 4
Target f
  Unit 0   Disk   HITACHI  H103030SCSUN300G A2A8    585937500 Blocks, 300 GB
  SASDeviceName 5000cca00a76dec0  SASAddress 5000cca00a76dec1  PhyNum 5
Target 10
  Unit 0   Disk   HITACHI  H103030SCSUN300G A2A8    585937500 Blocks, 300 GB
  SASDeviceName 5000cca00a773eac  SASAddress 5000cca00a773ead  PhyNum 6
Target 11
  Unit 0   Disk   SEAGATE  ST930003SSUN300G 0768    585937500 Blocks, 300 GB
  SASDeviceName 5000c5001d09654f  SASAddress 5000c5001d09654d  PhyNum d
Target 12
  Unit 0   Encl Serv device   SUN      SAS2 X16DBP      0305
  SASAddress 50800200000272bd  PhyNum 18
 
ok
 
 
 
 
Related Information