Skip Navigation Links | |
Exit Print View | |
Sun Storage 6580 and 6780 Arrays Hardware Release Notes, Release 6.9.x Update |
1. Sun Storage 6580 and 6780 Array Hardware Release Notes
What's In This Firmware Release
Platform and Firmware Patch IDs
Downloading Patches and Updates
Cache Battery Expiration Notification
Array Expansion Module Support
Supported Host Bus Adaptors (HBAs)
Supported FC and Multilayer Switches
Procedure (Offline)—for ESX4.1U2, ESXi5.0 and prior
Procedure (Offline)—starting at ESX4.1U3, ESXi5.0U1 and above
Installation and Hardware Related Issues
Log Events Using SLES 11.1 With smartd Monitoring Enabled
Kernel Panics During Controller Firmware (CFW) Download
Kernel Panics During Controller Firmware Download
Network Interface on Device eth0 Fails to Come Online When Booting a Host
Unable to Add More Than 117 Volumes to the Oracle Virtual Machine (OVM) Manager Database
After an NVSRAM Download, a Controller Reboots a Second Time when the NVSRAM is Activated
Data is Misread when a Physical Drive Has an Unreadable Sector
Total Cache Size Specification for Sun Storage 6780 Array
Firmware revision 07.84.44.10 delivers the following fixes:
15704695 (CR 7030331)—6x80/2500_M2: Controller Summ pg IPv6 Routable Addresses do not display correct values
15759870 (CR 7119324)—3 leds (Service Allowed, Service Required, Power OK) are on controller PSU after power outage
15767160 (CR 7131261)—Error flag on failed write buffer incorrectly cleared, ultimately leading to ancient I/O
15778292 (CR 7152868)—Controller rebooted due to ASSERT: Assertion failed: lu, file hidDstDevice.cc, line 74
15818269 (CR 7200803)—2500M2/6x80 Write cache Enabled/Inactive after 2nd reinsertion of controller
15810254 (CR 7191711)—(symTask2): PANIC: Assertion failed: file cacheCacheMgr.cc, line 10071
15680299 (CR 6998633)—ESM/IOM cards may reboot and cause errors in eventlog
15720063 (CR 7051420—600G 15K SEAGATE SMART failure in appliance SN: 001115E0NAHH
15766957 (CR 7131010)—FW 0605 not in the upgrade path for ST330057SSUN300G and ST360057SSUN600G in CAM 6.9
15770825 (CR 7142578)—X4370M2 Seagate HDD high number of drive failures
15743119 (CR 7093236)—6x40: Write Cache remains disabled on one controller following ICC replacement.
15756478 (CR 7114196)—6x40/6x80: Controller reboots during drive swaps - FC for SATA or SATA for FC
15573171 (CR 6856441)—6x40: Tray loss protection compromised after adding capacity (drives) to a VG.
15761011 (CR 7121304)—6x40: Expanding the primary volume of an RVM pair causes both array controllers to go offline.
15778119 (CR 7152626)—2500LCA/6x40:Unable to reset battery near expiry via CAM due to non-GMT tz of mgt client
15791360 (CR 7168377)—6x80/6x40/2500-LCA/2500-M2:Unable to recover multi-bit ECC errors by reading from alt controller
15791363 (CR 7168380)—2500M2- SB ECC reporting not enabled after RPA scrub on snowmass
15792036 (CR 7169253)—2500M2/2500LCA/6x40/6x80: DDC didn't collect complete information after AIOs
15802541 (CR 7182597)—6x40/6x80 running 07.60.56.10 or lower code get 'unrecovered read' error but VDD does not recover it
15802542 (CR 7182598)—6x40/6x80 running 07.60.56.10 or lower code get 'unrecovered read' error but VDD does not recover it
15763203 (CR 7125089)—2500LCA/2500M2/6x80/6x40: 7.x code can suspend media scan without warning.
15810495 (CR 7191991)—Firmware E5C4 not in upgrade path in D_HUS1561FCSUN600G_E6C0.dlp with CAM 6.9.0_19
15691552 (CR 7012227)—write performance issue on Seagate disks
15695312 (CR 7017161)—Slow disk performance on Seagate ST32502N HDDs
Firmware revision 07.80.62.10 delivered the following fixes for Sun Storage 6180 arrays.
15763203 (CR 7125089)—2500LCA/2500M2/6x80/6x40: 7.x code can suspend media scan without warning.
15767948 (CR 7132372)—2500-m2/6180: rev07 battery failed during learn cycle
15769192 (CR 7134932)—2500-M2/6180: Incomplete battery learn cycle due to inhibit charge bit set
15791360 (CR 7168377)—6x80/6x40/2500-LCA/2500-M2:Unable to recover multi-bit ECC errors by reading from alt controller
15791363 (CR 7168380)—2500M2- SB ECC reporting not enabled after RPA scrub on snowmass
15792036 (CR 7169253)—2500M2/2500LCA/6x40/6x80: DDC didn't collect complete information after AIOs