Confirming Server Specifications
Optional Component Installation
Determine Correct Rackmount Hardware
Mark the Rackmounting Location
Install the Rackmount Hardware
Installing and Using the Shipping Bracket Assembly (Optional)
Front Panel Connectors and Ports
Rear Panel Connectors and Ports
Installing and Using the CMA (Optional)
Connect the Ethernet Network Cables
Powering On the Server for the First Time
Oracle ILOM System Console Overview
Connect a Terminal or Emulator to the SER MGT Port
Power On the Server for the First Time
Oracle Solaris OS Configuration Parameters
Assigning a Static IP Address to the Service Processor
Booting the Oracle Solaris Operating System
Understanding System Administration Resources
Platform-Specific Oracle ILOM Features
Oracle VM Server for SPARC Overview
Hardware Management Pack Overview
Source for Downloading Hardware Management Pack Software
Hardware Management Pack Documentation
Display the Oracle ILOM -> Prompt
Reset the Server From the Oracle Solaris OS
Reset the Server From Oracle ILOM
Reset the SP to Default Values
Important Hardware RAID Guidelines
Disk Zones for SPARC T3-1 Servers With Sixteen-Disk Backplanes
Displaying Disk Zone Information
Enabling and Disabling Disk Zoning In the Field
Prepare to Use the FCode Utility
Hot Spare Drives in RAID Volumes (LSI)
Determining If a Drive Has Failed
RAID Drive Replacement Strategies
Changing Server Identification Information
Change Customer FRUdata Information
Change System Identifier Information
Restore Host Power State at Restart
Specify Host Power State at Restart
Disable or Re-Enable Power-On Delay
Specify Parallel Boot of the SP and Host
Configure Host Behavior With the Keyswitch State
Disable or Re-Enable Network Access to the SP
Display the DHCP Server IP Address
Using an In-band Connection to the SP
Configure the Host Boot Mode of Oracle VM Server for SPARC
Change the Host Boot Mode Behavior at Reset
Manage the Host Boot Mode Script
Display Host Boot Mode Expiration Date
Override OpenBoot PROM Settings to Reset the Server
Configuring Server Behavior at Restart
Specify Behavior When the Host Resets
Specify Behavior When the Host Stops Running
Specify Behavior at Boot Timeout
Specify Behavior if Restart Fails
Specify Maximum Restart Attempts
Enabling Automatic System Recovery
Identifying WWN-Designated SAS2 Devices
probe-scsi-all Output Example (SPARC T3-1, Eight-Disk Backplane)
probe-scsi-all Output Example (SPARC T3-1, Sixteen-Disk Backplane)
Identify a Disk Slot Using probe-scsi-all (OBP)
Identify a Disk Slot Using prtconf (Oracle Solaris, Onboard Controllers)
Identify a Disk Slot Using prtconf (Oracle Solaris, Single Initiator)
WWN Syntax in an OS Installation on a Specific Device
WWN Syntax in an OS Installation on a RAID Volume
Interpreting Log Files and System Messages
Using Oracle Solaris Predictive Self-Healing
Find the Chassis Serial Number
Understanding Component Replacement Categories
Removing Power From the System
Processor Module Configuration Reference
Replacing a Faulty Processor Module
Install a New Processor Module
Verify Processor Module Functionality
Memory Fault Handling Overview
Understanding DIMM Configurations
Locate a Faulty DIMM Using the DIMM Fault Remind Button
Locate a Faulty DIMM Using the show faulty Command
Increase System Memory With Additional DIMMs
Hard Drive Hot-Pluggable Capabilities
Hard Drive Configuration Reference
Verify Hard Drive Functionality
Power Supply and AC Power Connector Configuration Reference
Power Supply and AC Power Connector LEDs
Verify Power Supply Functionality
Servicing RAID Expansion Modules
Remove the RAID Expansion Module
Install the RAID Expansion Module
Servicing the Service Processor
Locate a Faulty Service Processor
Verify Service Processor Functionality
Fan Module Configuration Reference
Verify Fan Module Functionality
Express Module Configuration Reference
Locate a Faulty Express Module
Verify Express Module Functionality
Locate a Faulty Rear I/O Module
Verify Rear I/O Module Functionality
Servicing the System Configuration PROM
System Configuration PROM Overview
Remove the System Configuration PROM
Install the System Configuration PROM
Servicing the Front I/O Assembly
Install the Front I/O Assembly
Servicing the Storage Backplane
Servicing the Main Module Motherboard
Main Module Motherboard Overview
Locate a Faulty Main Module Motherboard
Remove the Main Module Motherboard
Install the Main Module Motherboard
Verify Main Module Motherboard Functionality
Servicing the Rear Chassis Subassembly
Rear Chassis Subassembly Overview
Remove the Rear Chassis Subassembly
Install the Rear Chassis Subassembly
Returning the Server to Operation
Connect Power Cords to the Server
Power On the Server (start /SYS Command)
When analyzing probe-scsi-all output, look for this SAS device information:
SASDeviceName -- This is the WWN that the Oracle Solaris OS recognizes.
SASAddress -- This is the WWN that the OBP recognizes.
PhyNum -- This is a hexadecimal value that identifies the port that a disk is connected to.
VolumeDeviceName -- When a RAID volume has been configured, this is the RAID volume WWN value recognized by the Oracle Solaris OS.
VolumeWWID -- When a RAID volume has been configured, this is the RAID volume WWN value referenced by OBP.
A SPARC T3-4 server has two onboard SAS controllers, each connected to a separate four-disk capable backplane. The following table shows the PhyNum-to-disk slot correspondence for these backplanes.
Table 6 SAS Controller Port Mapping for an Eight-Disk Backplane
|
Note - OBP uses a different device path for SAS controller 1 in SPARC T3-4 servers, depending on whether the server has four-processors or two processors. The path for SAS Controller 0 is the same for both processor configurations.
The following example illustrates probe-scsi-all output for a SPARC T3-4 with four processors and eight drives.
Because SAS controller 0 controls the hard drives installed in backplane slots 0-3, the default boot device for this example is PhyNum 0 in the group of hard drives under controller 0. It has a SASDeviceName value of 5000cca00a75dcac and a SASAddress value of 5000cca00a75dcad.
ok probe-scsi-all /pci@700/pci@1/pci@0/pci@0/LSI,sas@0 <---- SAS controller 1 FCode Version 1.00.54, MPT Version 2.00, Firmware Version 5.00.17.00 Target 9 Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abc5cc8 SASAddress 5000cca00abc5cc9 PhyNum 0 Target a Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abaf620 SASAddress 5000cca00abaf621 PhyNum 1 Target b Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abcec4c SASAddress 5000cca00abcec4d PhyNum 2 Target c Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abc5218 SASAddress 5000cca00abc5219 PhyNum 3 /pci@400/pci@1/pci@0/pci@8/pci@0/usb@0,2/hub@2/hub@3/storage@2 Unit 0 Removable Read Only device AMI Virtual CDROM 1.00 /pci@400/pci@1/pci@0/pci@0/LSI,sas@0 <---- SAS controller 0 FCode Version 1.00.54, MPT Version 2.00, Firmware Version 5.00.17.00 Target 9 Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abcede0 SASAddress 5000cca00abcede1 PhyNum 0 Target a Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abc51a8 SASAddress 5000cca00abc51a9 PhyNum 1 Target b Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abce89c SASAddress 5000cca00abce89d PhyNum 2 Target c Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 G SASDeviceName 5000cca00abc5354 SASAddress 5000cca00abc5355 PhyNum 3
The following example illustrates probe-scsi-all output for a SPARC T3-4 with two processors and eight drives.
Because SAS controller 0 controls the hard drives installed in backplane slots 0-3, the default boot device for this example is PhyNum 0 in the group of hard drives under controller 0. It has a SASDeviceName value of 5000cca00a75dcac and a SASAddress value of 5000cca00a75dcad.
ok probe-scsi-all /pci@500/pci@1/pci@0/pci@0/LSI,sas@0 <---- SAS controller 1 FCode Version 1.00.54, MPT Version 2.00, Firmware Version 5.00.17.00 Target 9 Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abc5cc8 SASAddress 5000cca00abc5cc9 PhyNum 0 Target a Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abaf620 SASAddress 5000cca00abaf621 PhyNum 1 Target b Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abcec4c SASAddress 5000cca00abcec4d PhyNum 2 Target c Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abc5218 SASAddress 5000cca00abc5219 PhyNum 3 /pci@400/pci@1/pci@0/pci@8/pci@0/usb@0,2/hub@2/hub@3/storage@2 Unit 0 Removable Read Only device AMI Virtual CDROM 1.00 /pci@400/pci@1/pci@0/pci@0/LSI,sas@0 <---- SAS controller 0 FCode Version 1.00.54, MPT Version 2.00, Firmware Version 5.00.17.00 Target 9 Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abcede0 SASAddress 5000cca00abcede1 PhyNum 0 Target a Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abc51a8 SASAddress 5000cca00abc51a9 PhyNum 1 Target b Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 GB SASDeviceName 5000cca00abce89c SASAddress 5000cca00abce89d PhyNum 2 Target c Unit 0 Disk HITACHI H103030SCSUN300G A2A8 585937500 Blocks, 300 G SASDeviceName 5000cca00abc5354 SASAddress 5000cca00abc5355 PhyNum 3