JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Blade Storage Module M2 Product Documentation
search filter icon
search icon

Document Information

Preface

Product Information Web Site

Related Books

About This Documentation (PDF and HTML)

Documentation Comments

Change History

Hardware Installation

Overview of the Sun Blade Storage Module M2

System Requirements

Installing the Storage Module Into the Chassis

Storage Module Indicators

Assigning and Managing Storage

Product Notes

Overview of the Sun Blade Storage Module M2 Product Notes

Supported Firmware, Hardware and Software

Storage Module Firmware Release History

Supported Hardware

Supported Operating Systems

Integrated Lights Out Manager (ILOM)

Get Software and Firmware Downloads

Hardware Issues

Solaris Operating System Issues

Linux Operating System Issues

Administration

Assigning Storage to Hosts

Managing Storage

Performing Maintenance and Hot Plug Actions

Importing Existing Virtual Drives to a Replacement REM

Storage Module Sensors and Indicators

Troubleshooting

Service

Introduction to the Sun Blade Storage Module M2

Maintaining the Sun Blade Storage Module M2

Diagnosing Storage Module Faults

Specifications

Index

Supported Hardware

The following hardware is supported for use with your storage module. To download available software, see Get Software and Firmware Downloads. Patches are available from Sun System Software Stacks (http://www.oracle.com/technetwork/systems/software-stacks/stacks/index.html).

Servers
SAS-2 REMs
Chassis
SAS-2 NEMs
Sun Blade T3–B1 (SPARC), with system firmware 8.1.0.c or later (Sunsolve patch 147315-02).
  • Sun Storage 6Gb SAS REM HBA (SGX-SAS6-REM-Z)

    See note 2 below.

  • Sun Blade 6000 Modular System with PCIe 2.0 midplane
  • Sun Blade 6000 Virtualized Multi-Fabric 10GbE M2 NEM

    See note 4 below.

  • Sun Blade 6000 Switched NEM 24p 10GbE

    See notes 4 and 5 below.

Sun Blade T6320 G2 (SPARC), with system firmware 7.2.8 or later (Sunsolve patch 139440-11).

See note 1 below.

  • Sun Storage 6Gb SAS REM HBA (SGX-SAS6-REM-Z)

    See note 2 below.

  • Sun Blade 6000 Modular System with PCIe 2.0 midplane
  • Sun Blade 6000 Virtualized Multi-Fabric 10GbE M2 NEM

    See note 4 below.

  • Sun Blade 6000 Switched NEM 24p 10GbE

    See notes 4 and 5 below.

Sun Blade T6340 (SPARC), with system firmware 7.2.8 or later (Sunsolve patch 139448-10).

See note 1 below.

  • Sun Storage 6Gb SAS REM HBA (SGX-SAS6-REM-Z)

    See note 2 below.

  • Sun Blade 6000 Modular System with PCIe 2.0 midplane
  • Sun Blade 6000 Virtualized Multi-Fabric 10GbE M2 NEM

    See note 4 below.

  • Sun Blade 6000 Switched NEM 24p 10GbE

    See notes 4 and 5 below.

Sun Blade X6270 M2 (x86)
  • Sun Storage 6Gb SAS REM RAID HBA (SGX-SAS6-R-REM-Z)

    See note 2 below.

  • Sun Blade 6000 Modular System with PCIe 2.0 midplane
  • Sun Blade 6000 Virtualized Multi-Fabric 10GbE M2 NEM

    See note 4 below.

  • Sun Storage 6Gb SAS REM HBA (SGX-SAS6-REM-Z)

    See note 2 and 3 below.

  • Sun Blade 6000 Modular System with PCIe 2.0 midplane
  • Sun Blade 6000 Virtualized Multi-Fabric 10GbE M2 NEM

    See note 4 below.

  • Sun Blade 6000 Switched NEM 24p 10GbE

    See notes 4 and 5 below.

Notes:

  1. The Sun Blade T6320 and T6340 server modules are supported for use in a SAS-2 environment with a SAS-2 REM, but are limited to a maximum 3 Gb/s data transfer speed.

  2. The Sun Storage 6Gb SAS REMs include software and firmware. You should always use the latest versions. To download the latest updates for these REMs, go to the LSI Support site.

  3. The Sun Storage 6Gb SAS REM HBA (SGX-SAS6-REM-Z) in a Sun Blade X6270 M2 server module is only supported for use with a Sun Blade Storage Module M2 if the storage module firmware is 5.3.6.0 or later. The minimum firmware for the storage module in this configuration is included in Sun Blade Storage Module M2 software release 1.0.1.

  4. As of the release of this document, there is no support for using the external SAS-2 connectors of a SAS-2 NEM (such as the Sun Blade 6000 Virtualized Multi-Fabric 10GbE M2 NEM) to add external storage. Additional external storage may be added by installing a PCIe ExpressModule (EM) HBA and connecting external storage devices to it. The external storage is then controlled by the server module and its PCIe EM, and is not part of the chassis SAS-2 domain.

  5. The Sun Blade 6000 Ethernet Switched NEM 24p 10GbE is only supported for use with a Sun Blade Storage M2 if NEM software release 1.1 or later is installed.