SCSI controller c1 provides an example of connecting a SCSI controller.
Become superuser.
Verify the device is disconnected before connecting it.
# cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c0::dsk/c0t0d0 disk connected configured unknown c0::rmt/0 tape connected configured unknown c1 unavailable disconnected configured unknown c1::dsk/c1t10d0 unavailable disconnected configured unknown c1::dsk/c1t4d0 unavailable disconnected configured unknown |
Connect a SCSI controller.
# cfgadm -c connect c1 |
Verify the SCSI controller is connected.
# cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c0::dsk/c0t0d0 disk connected configured unknown c0::rmt/0 tape connected configured unknown c1 scsi-bus connected configured unknown c1::dsk/c1t3d0 disk connected configured unknown c1::dsk/c1t4d0 disk connected configured unknown |