This chapter describes the sensors and indicators that can be accessed through the ILOM.
Sensors report physical information about the server, including voltages, temperatures, fan speeds, and installation and removal of components. Indicators report important server conditions.
All sensors and indicators are IPMI-compliant.
Entity Presence
These sensors report the presence or absence of system components.
- P0 and P1 represent CPU 0 and CPU 1
- D0 through D5 represent DIMMs 1 through 6.
TABLE 4-3 Entities Present
Name
|
Type
|
Reading
|
/SYS/SLOTID
|
Slot ID of server module
|
0
|
/SYS/CMM/PRSNT
|
CMM Presence
|
Present
|
/SYS/PEM/PRSNT
|
PEM Presence
|
Absent
|
/SYS/MB/P0/PRSNT
|
Processor 0 Presence
|
Present
|
/SYS/MB/P1/PRSNT
|
Processor 1 Presence
|
Absent
|
/SYS/MB/P0/D0/PRSNT
|
DIMM Presence
|
Absent
|
/SYS/MB/P0/D1/PRSNT
|
DIMM Presence
|
Present
|
/SYS/MB/P0/D2/PRSNT
|
DIMM Presence
|
Absent
|
/SYS/MB/P0/D3/PRSNT
|
DIMM Presence
|
Present
|
/SYS/MB/P0/D4/PRSNT
|
DIMM Presence
|
Absent
|
/SYS/MB/P0/D5/PRSNT
|
DIMM Presence
|
Present
|
/SYS/MB/P1/D0/PRSNT
|
DIMM Presence
|
Absent
|
/SYS/MB/P1/D1/PRSNT
|
DIMM Presence
|
Absent
|
/SYS/MB/P1/D2/PRSNT
|
DIMM Presence
|
Absent
|
/SYS/MB/P1/D3/PRSNT
|
DIMM Presence
|
Absent
|
/SYS/MB/P1/D4/PRSNT
|
DIMM Presence
|
Absent
|
/SYS/MB/P1/D5/PRSNT
|
DIMM Presence
|
Absent
|
Temperature and Power
These sensors report on the temperature sensors and the power consumption.
TABLE 4-4 Temperature and Power Sensors
Name
|
Type
|
Reading
|
/SYS/MB/T_AMB_FRONT
|
Temperature
|
24.000 degrees C
|
/SYS/MB/T_AMB_REAR
|
Temperature
|
55.000 degrees C
|
/SYS/VPS
|
System power (watts)
|
88.200 Watts
|
/SYS/HOT
|
OEM
|
State Asserted
|
Fan Failure
These sensors assert predictive failure when a fan is expected to fail. Normally, they should read “Predictive Failure Deasserted.”
TABLE 4-5 Fan Failure Sensors
Name
|
Type
|
Reading
|
/SYS/FM0/ERR
|
Fan
|
Predictive Failure Asserted
|
/SYS/FM1/ERR
|
Fan
|
Predictive Failure Deasserted
|
/SYS/FM2/ERR
|
Fan
|
Predictive Failure Deasserted
|
/SYS/FM3/ERR
|
Fan
|
Predictive Failure Asserted
|
/SYS/FM4/ERR
|
Fan
|
Predictive Failure Asserted
|
/SYS/FM5/ERR
|
Fan
|
Predictive Failure Deasserted
|
/SYS/FM6/ERR
|
Fan
|
Predictive Failure Deasserted
|
/SYS/FM7/ERR
|
Fan
|
Predictive Failure Asserted
|
Chassis Fan Speed
These sensors indicate the speed of the chassis fans. The chassis fans are divided into eight modules (FM0 through FM7) with two fans each (F0 and F1).
TABLE 4-6 Chassis Fan Speed Measurements
Name
|
Type
|
Reading
|
/SYS/FM0/F0/TACH
|
Fan
|
0.000 RPM
|
/SYS/FM0/F1/TACH
|
Fan
|
0.000 RPM
|
/SYS/FM1/F0/TACH
|
Fan
|
5600.000 RPM
|
/SYS/FM1/F1/TACH
|
Fan
|
5400.000 RPM
|
/SYS/FM2/F0/TACH
|
Fan
|
5400.000 RPM
|
/SYS/FM2/F1/TACH
|
Fan
|
5400.000 RPM
|
/SYS/FM3/F0/TACH
|
Fan
|
0.000 RPM
|
/SYS/FM3/F1/TACH
|
Fan
|
0.000 RPM
|
/SYS/FM4/F0/TACH
|
Fan
|
0.000 RPM
|
/SYS/FM4/F1/TACH
|
Fan
|
0.000 RPM
|
/SYS/FM5/F0/TACH
|
Fan
|
5300.000 RPM
|
/SYS/FM5/F1/TACH
|
Fan
|
5600.000 RPM
|
/SYS/FM6/F0/TACH
|
Fan
|
5300.000 RPM
|
/SYS/FM6/F1/TACH
|
Fan
|
5400.000 RPM
|
/SYS/FM7/F0/TACH
|
Fan
|
0.000 RPM
|
/SYS/FM7/F1/TACH
|
Fan
|
0.000 RPM
|
NEM and Blade Presence
These sensors indicate whether there are NEMs in NEM slots 0 and 1, and whether any blades are in slots 0 through 11.
The X6275 server module has two nodes, 0 and 1.
- Node 0 appears in the actual physical slot.
- Node 1 appears in the physical slot + 12.
For example, for an X6275 server module in slot 6, node 0 appears to be in slot 6, and node 1 appears to be in slot 18.
TABLE 4-7 NEM and Blade Presence
Name
|
Type
|
Reading
|
/SYS/NEM0/PRSNT
|
Entity Presence
|
Present
|
/SYS/NEM1/PRSNT
|
Entity Presence
|
Present
|
/SYS/BL0/PRSNT
|
Entity Presence
|
Present
|
/SYS/BL1/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL2/PRSNT
|
Entity Presence
|
Present
|
/SYS/BL3/PRSNT
|
Entity Presence
|
Present
|
/SYS/BL4/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL5/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL6/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL7/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL8/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL9/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL10/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL11/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL12/PRSNT
|
Entity Presence
|
Present
|
/SYS/BL13/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL14/PRSNT
|
Entity Presence
|
Present
|
/SYS/BL15/PRSNT
|
Entity Presence
|
Present
|
/SYS/BL16/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL17/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL18/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL19/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL20/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL21/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL22/PRSNT
|
Entity Presence
|
Absent
|
/SYS/BL23/PRSNT
|
Entity Presence
|
Absent
|
Power Supplies
These readings show the state of the power supplies, which are located on the chassis.
Power Supply Present
This sensor indicates whether the power signal is present.
TABLE 4-8 Power Supply Present
Name
|
Type
|
Reading
|
/SYS/PS0/PRSNT
|
Entity Presence
|
Absent
|
/SYS/PS1/PRSNT
|
Entity Presence
|
Present
|
Power Supply OK
These readings are asserted when the power supply is OK and deasserted when the designated power supply generates a fault.
TABLE 4-9 Power Supply OK
Name
|
Type
|
Reading
|
/SYS/PS0/PWROK0
|
Power Supply
|
Disabled
|
/SYS/PS0/PWROK1
|
Power Supply
|
Disabled
|
/SYS/PS0/PWROK2
|
Power Supply
|
Disabled
|
/SYS/PS1/PWROK0
|
Power Supply
|
State Asserted
|
/SYS/PS1/PWROK1
|
Power Supply
|
State Asserted
|
/SYS/PS1/PWROK2
|
Power Supply
|
State Deasserted
|
Power Supply Error
Each power supply has three AC inputs. These readings are deasserted when the AC input is OK, and asserted when there is a problem with the corresponding AC input.
TABLE 4-10 Error Indication Sensors
Name
|
Type
|
Reading
|
/SYS/PS0/AC0_ERR
|
Power Supply
|
Disabled
|
/SYS/PS0/AC1_ERR
|
Power Supply
|
Disabled
|
/SYS/PS0/AC2_ERR
|
Power Supply
|
Disabled
|
/SYS/PS1/AC0_ERR
|
Power Supply
|
State Deasserted
|
/SYS/PS1/AC1_ERR
|
Power Supply
|
State Deasserted
|
/SYS/PS1/AC2_ERR
|
Power Supply
|
Not Readable
|
Indicators
These report the state of the system indicators, including LEDs.
See the Sun Blade X6275 Installation Guide for descriptions of the LEDs and indicators.
TABLE 4-11 Indicators
Path
|
Indicator
|
Description
|
/SYS/OK
|
Green OK LED
|
Slow Blink
|
/SYS/OK2RM
|
Blue OK to Remove LED
|
Off
|
/SYS/SERVICE
|
Amber Service LED
|
Off
|
/SYS/LOCATE
|
White Locate LED
|
Off
|
/SYS/MB/P0/SERVICE
|
CPU error condition
|
Off
|
/SYS/MB/P0/D1/SERVICE
|
DIMM error condition
|
Off
|
/SYS/MB/P0/D3/SERVICE
|
DIMM error condition
|
Off
|
/SYS/MB/P0/D5/SERVICE
|
DIMM error condition
|
Off
|