JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun SPARC Enterprise T5440 Server Topic Set
PDF
search filter icon
search icon

Document Information

Using This Documentation

Related Documentation

Documentation, Support, and Training

Site Planning

SPARC Enterprise T5440 Site Planning Guide

Physical Specifications

Minimum Clearance for Service Access

Environmental Specifications

Power Source Requirements

Acoustic Noise Emissions

Agency Compliance Specifications

Operating Environment Requirements

Installation and Setup

Preparing for Installation

About the SPARC Enterprise T5440 Server

Tools and Equipment Needed

Installation Overview

Cabling Notes

About the Slide Rail Assembly

About the Cable Management Arm

Rack Compatibility Requirements

Safety Precautions

ESD Precautions

Installing the SPARC Enterprise T5440 Server

Installing the Rack Slide Assembly

Installing the Server Into the Cabinet

Installing the Cable Management Arm (CMA)

Connecting the Server Cables

Managing Cables With the CMA

Powering On the System

Powering On the System for the First Time

Enabling the Service Processor Network Management Port

Logging Into the Service Processor

Using the Service Processor for Common Operations

Booting the Solaris Operating System

Updating the Firmware

Updating Service Processor and Server Firmware

Updating the Firmware

Selecting a Boot Device

Select a Boot Device

Administration

Basic Administrative Tasks

Initial System Setup

Communicating With the System

Performing Common Tasks

Manage Disk Volumes

Hardware RAID Support

Creating RAID Volumes

Removing Hardware RAID Volumes

Manage the System

Searching for Faults

Bypassing Minor Faults

Clearing Faults

Managing Devices

Use Logical Domains Software

Understanding Logical Domains Software

Operating the Solaris OS With Logical Domains

ALOM-to-ILOM Command Reference

ILOM and ALOM CMT Command Comparison Tables

Remote Management

Understanding ILOM for the Sun SPARC Enterprise T5440 Server

ILOM Overview

Platform-Specific ILOM Features

ILOM Features Not Supported

Managing the Host

Resetting the Host

Managing Host Boot Mode

Viewing and Configuring Host Control Information

Managing System User Interactions

Managing the Service Processor

Storing Customer Information

Display Console History (CLI)

Change Console Escape Characters (CLI)

Changing Configuration Policy Settings

Managing Network Access

Managing Devices

Managing Virtual Keyswitch Settings

IPMI Sensor Reference

Sensors on Sun SPARC Enterprise T5440 Server

Indicators on the Sun SPARC Enterprise T5440 Server Server

ALOM CMT Compatibility Shell

Limits to Backward Compatibility

Create an ALOM CMT Compatibility Shell

ILOM and ALOM CMT Command Comparison

ALOM CMT Variables

ALOM CMT Variable Comparison

Event Messages Available Through the ALOM Compatibility Shell

Event Message Overview

Event Severity Levels

Service Processor Usage Event Messages

Environmental Monitoring Event Messages

Host Monitoring Event Messages

SCC Backup and Restore

Information Stored on The SCC

Service

Identifying Server Components

Infrastructure Boards and Cables

Front Panel Diagram

Front Panel LEDs

Rear Panel Diagram

Rear Panel LEDs

Ethernet Port LEDs

Managing Faults

Understanding Fault Handling Options

Connecting to the Service Processor

Displaying FRU Information With Oracle ILOM

Controlling How POST Runs

Detecting Faults

Clearing Faults

Disabling Faulty Components

Oracle ILOM-to-ALOM CMT Command Reference

Preparing to Service the System

Safety Information

Required Tools

Obtain the Chassis Serial Number

Obtain the Chassis Serial Number Remotely

Powering Off the System

Extending the Server to the Maintenance Position

Remove the Server From the Rack

Perform Electrostatic Discharge – Antistatic Prevention Measures

Remove the Top Cover

Servicing Customer-Replaceable Units

Hot-Pluggable and Hot‐Swappable Devices

Servicing Hard Drives

Servicing Fan Trays

Servicing Power Supplies

Servicing PCIe Cards

Servicing CMP/Memory Modules

Servicing FB-DIMMs

Servicing Field-Replaceable Units

Servicing the Front Bezel

Servicing the DVD-ROM Drive

Servicing the Service Processor

Servicing the IDPROM

Servicing the Battery

Servicing the Power Distribution Board

Servicing the Fan Tray Carriage

Servicing the Hard Drive Backplane

Servicing the Motherboard

Servicing the Flex Cable Assembly

Servicing the Front Control Panel

Servicing the Front I/O Board

Returning the Server to Operation

Install the Top Cover

Install the Server Into the Rack

Slide the Server Into the Rack

Connect the Power Cords to the Server

Power On the Server

Performing Node Reconfiguration

I/O Connections to CMP/Memory Modules

Recovering From a Failed CMP/Memory Module

System Bus Topology

I/O Fabric in 2P Configuration

I/O Fabric in 4P Configuration

Identifying Connector Pinouts

Serial Management Port Connector Pinouts

Network Management Port Connector Pinouts

Serial Port Connector Pinouts

USB Connector Pinouts

Gigabit Ethernet Connector Pinouts

Server Components

Customer-Replaceable Units

Field-Replaceable Units

Index

Numbers and Symbols

A

B

C

D

E

F

G

H

I

L

M

N

O

P

Q

R

S

T

U

V

X

C

cable management arm, Installing the Cable Management Arm (CMA)
cable management bracket, description, About the Cable Management Arm
cables
adapters for serial data cables, Connect the Service Processor Serial Management Port
connecting, Connecting the Server Cables
cfgadm command
Remove a Hard Drive (Hot-Plug)
Remove a Hard Drive (Hot-Plug)
Remove a Hard Drive (Hot-Plug)
Install a Hard Drive (Hot-Plug)
Install a Hard Drive (Hot-Plug)
Install a Hard Drive (Hot-Plug)
Install a Hard Drive (Hot-Plug)
Install a Hard Drive (Hot-Plug)
chassis
dimensions, Infrastructure Boards and Cables
serial number, Obtain the Chassis Serial Number
clearfault command, Oracle ILOM-to-ALOM CMT Command Reference
clearing POST-detected faults, Clear Faults Detected During POST
clearing PSH-detected faults, Clear Faults Detected by PSH
CMP/memory module, Install a CMP/Memory Module
adding, Add a CMP/Memory Module
command
cfgadm
Remove a Hard Drive (Hot-Plug)
Remove a Hard Drive (Hot-Plug)
Remove a Hard Drive (Hot-Plug)
Install a Hard Drive (Hot-Plug)
Install a Hard Drive (Hot-Plug)
Install a Hard Drive (Hot-Plug)
Install a Hard Drive (Hot-Plug)
Install a Hard Drive (Hot-Plug)
disablecomponent
Disable System Components
Re-Enable System Components
fmdump, Detect Faults Identified by the Oracle Solaris PSH Facility (Oracle ILOM fmdump Command)
iostat -E, Install a Hard Drive (Hot-Plug)
removefru, Oracle ILOM-to-ALOM CMT Command Reference
set /SYS keyswitch_state
Power On the System
Power On the System
setlocator
Front Panel LEDs
Rear Panel LEDs
Oracle ILOM-to-ALOM CMT Command Reference
Extend the Server to the Maintenance Position
Extend the Server to the Maintenance Position
show faulty
Detecting Faults Using LEDs
Detecting Faults (Oracle ILOM show faulty Command)
Verify FB‐DIMM Replacement
showfaults, Oracle ILOM-to-ALOM CMT Command Reference
showfru
Display Individual Component Information (Oracle ILOM show Command)
Oracle ILOM-to-ALOM CMT Command Reference
command-line access, ILOM, Logging Into the Service Processor
commit network configuration properties, Commit a Change to a Network Configuration Property
compatible racks
Rack Compatibility Requirements
Rack Compatibility Requirements
component_state (ILOM component property), Clear Faults Detected During POST
components
disabled automatically by POST, Disabling Faulty Components Using Automatic System Recovery
disabling usingdisablecomponent command
Disable System Components
Re-Enable System Components
displaying state of, Disabling Faulty Components Using Automatic System Recovery
displaying usingshowcomponent command, Display System Components (Oracle ILOM show components Command)
configuration information needed, Installation Overview
configuring the network management port, Enabling the Service Processor Network Management Port
connecting to ALOM CMT, Connecting to the Service Processor
connecting to the system console, Connect to the System Console
console command
Power Cycle the System
Run POST in Maximum Mode
Oracle ILOM-to-ALOM CMT Command Reference
Verify FB‐DIMM Replacement
consolehistory command, Oracle ILOM-to-ALOM CMT Command Reference