Sun Cluster System Administration Guide for Solaris OS

ProcedureHow to Shut Down a Cluster Node


Caution – Caution –

Do not use send brk on a cluster console to shut down a cluster node. The command is not supported within a cluster.


Steps
  1. SPARC: If your cluster is running Oracle Parallel Server or Oracle Real Application Clusters, shut down all instances of the database.

    Refer to the Oracle Parallel Server or Oracle Real Application Clusters product documentation for shutdown procedures.

  2. Become superuser on the cluster node to be shut down.

  3. Switch all resource groups, resources, and device groups from the node being shut down to other cluster members.

    On the node to be shut down, type the following command.


    # scswitch -S -h node
    
    -S

    Evacuates all device services and resource groups from the specified node.

    -h node

    Specifies the node from which you are switching resource groups and device groups.

  4. Shut down the cluster node.

    On the node to be shut down, type the following command.


    # shutdown -g0 -y -i0
    
  5. Verify that the cluster node is showing the ok prompt or the Select (b)oot or (i)nterpreter prompt on the Current Boot Parameters screen.

  6. If necessary, power off the node.


Example 3–7 SPARC: Shutting Down a Cluster Node

The following example shows the console output when shutting down node phys-schost-1. The -g0 option sets the grace period to zero, -y provides an automatic yes response to the confirmation question, and -i0 invokes run level 0 (zero). Shutdown messages for this node appear on the consoles of other nodes in the cluster.


# scswitch -S -h phys-schost-1
# shutdown -g0 -y -i0
Wed Mar 10 13:47:32 phys-schost-1 cl_runtime:
WARNING: CMM monitoring disabled.
phys-schost-1# 
INIT: New run level: 0
The system is coming down.  Please wait.
Notice: rgmd is being stopped.
Notice: rpc.pmfd is being stopped.
Notice: rpc.fed is being stopped.
umount: /global/.devices/node@1 busy
umount: /global/phys-schost-1 busy
The system is down.
syncing file systems... done
Program terminated
ok 


Example 3–8 x86: Shutting Down a Cluster Node

The following example shows the console output when shutting down node phys-schost-1. The -g0 option sets the grace period to zero, -y provides an automatic yes response to the confirmation question, and -i0 invokes run level 0 (zero). Shutdown messages for this node appear on the consoles of other nodes in the cluster.


# scswitch -S -h phys-schost-1
# shutdown -g0 -y -i0
Shutdown started.    Wed Mar 10 13:47:32 PST 2004

Changing to init state 0 - please wait
Broadcast Message from root (console) on phys-schost-1 Wed Mar 10 13:47:32... 
THE SYSTEM phys-schost-1 IS BEING SHUT DOWN NOW ! ! !
Log off now or risk your files being damaged

phys-schost-1#
INIT: New run level: 0
The system is coming down.  Please wait.
System services are now being stopped.
/etc/rc0.d/K05initrgm: Calling scswitch -S (evacuate)
failfasts disabled on node 1
Print services already stopped.
Mar 10 13:47:44 phys-schost-1 syslogd: going down on signal 15
umount: /global/.devices/node@2 busy
umount: /global/.devices/node@1 busy
The system is down.
syncing file systems... done
WARNING: CMM: Node being shut down.
Type any key to continue 

See Also