Sun StorEdge 3900 and 6900 Series 2.3.7 Release Notes

The Sun StorEdgetrademark 3900 and 6900 series storage systems are complete preconfigured storage solutions. The Sun StorEdge 3900 and 6900 series systems support direct-attach storage (DAS) and storage area network (SAN) environments.

This document is organized as follows:


Features in This Release

No new features were added during this revision of the Sun StorEdge 3900 and 6900 series storage systems.


Product Changes

The software revision in this release of the product:

TABLE 1 summarizes Sun StorEdge 3900 and 6900 series features supported with each Storage Service Processor software release. Each version of the Storage Service Processor software is available on CD. Upgrade CDs are also available to upgrade a Sun StorEdge 3900 or 6900 series from one software version to the next. For example, you can upgrade your system from version 2.0.2 to version 2.0.3, from 2.0.3 to version 2.1.1, and from version 2.1.1 to version 2.3.1.


TABLE 1 Features Supported by Storage Service Processor Versions

Features

Ver. 2.0.2
(Feb 2002)

Ver. 2.0.3
(May 2002)

Ver. 2.1.1
(Jun 2002)

Ver. 2.3.1
(Mar 2003)

Ver. 2.3.2
(Aug 2003)

Ver. 2.3.3
(Apr
2004)

Ver. 2.3.4
(Dec 2004)

Ver. 2.3.5
(Aug 2005)

Ver. 2.3.6
(Jan 2006)

Ver. 2.3.7
(Jun 2006)

Multinode cluster support for Sun StorEdge 3900 and 6900 series

 

 


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark

Multiple host support for Sun StorEdge 6900 series

 

 


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark

Sun StorEdge T3+ array LUN slicing and masking support (Sun StorEdge 3900 series only)

 

 



checkmark



checkmark



checkmark



checkmark



checkmark



checkmark



checkmark



checkmark

36-Gbyte and 72-Gbyte disk drive capacities


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark

Increased disk drive capacity (181-Gbyte drives)

 


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark

Sun StorEdge T3+ array firmware version 2.0.1


checkmark

 

 

 

 

 

 

 

 

 

Sun StorEdge T3+ array firmware version 2.1 (fabric support)

 


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark

Sun StorEdge T3+ array firmware version 3.1

 

 

 

 

 


checkmark


checkmark


checkmark


checkmark


checkmark

Sun StorEdge T3+ 3.1 disk scrubber feature

 

 

 

 

 


checkmark


checkmark


checkmark


checkmark


checkmark

Sun StorEdge T3+ 3.1 ONDG feature

 

 

 

 

 


checkmark


checkmark


checkmark


checkmark


checkmark

Sun StorEdge T3+ array RAID configuration with no hot spare

 

 

 


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark

Sun StorEdge T3+ array firmware version 3.2.2

 

 

 

 

 

 

 


checkmark


checkmark


checkmark

Sun StorEdge T3+ array firmware version 3.2.3

 

 

 

 

 

 

 

 


checkmark


checkmark

Sun StorEdge T3+ array firmware version 3.2.4

 

 

 

 

 

 

 

 

 


checkmark

Switch firmware version 3.04.62 (FC-switch FLASH 30462)


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark

Sun StorEdge network Fibre Channel Switch-8 and Switch-16 (1-Gbit) switch firmware version 40238 (2-Gbit/FC-SW compatible)

 

 

 



checkmark



checkmark



checkmark



checkmark



checkmark



checkmark



checkmark

Sun StorEdge network Fibre Channel Switch-8 and Switch-16 (1-Gbit) switch firmware version 40242 (2-Gbit/FC-SW compatible)

 

 

 

 

 




checkmark




checkmark




checkmark




checkmark




checkmark

Sun StorEdge network 2-Gbit Fibre Channel switch-16 support on front-end switches on the 3900 series only with switch firmware revision v1.3.60 or v1.5.07

 

 

 





checkmark





checkmark





checkmark





checkmark





checkmark





checkmark





checkmark

Sun StorEdge network 2-Gbit Fibre Channel switch-16 support on front-end switches on the 3900 series only with switch firmware revision 2.0.0.05

 

 

 

 

 





checkmark





checkmark





checkmark





checkmark





checkmark

Virtualization engine firmware version 8.014


checkmark

 

 

 

 

 

 

 

 

 

Virtualization engine firmware version 8.017 supporting:

  • Improved performance
    (8K-12K)
  • Failback without halting I/Os

 




checkmark




checkmark

 

 

 

 

 

 

 

Virtualization engine firmware 8.019 supporting:

  • Improved SVE check condition handling for Windows 2000 reboot
  • Corrected MH10 < STATUS return value
  • Corrected SCSI reservation issue

 

 

 


 



checkmark


 



checkmark

 

 

 

 

 

Virtualization engine firmware 8.020 supporting:

  • Corrected Inq page 0x83 fail to return correct data cause errhalt reboot
  • Sun StorEdge SAN Foundation software 4.3 support
  • Sun StorEdge SAN Foundation software 4.4 support

 

 

 

 


 



checkmark


 



checkmark






checkmark






checkmark


 



checkmark






checkmark






checkmark


 



checkmark






checkmark






checkmark


 



checkmark






checkmark






checkmark


 



checkmark






checkmark






checkmark

Sun StorEdge Remote Response ready

 


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark

Improved security for Sun StorEdge Remote Response

 


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark

Sun StorEdge SAN 3.2 support

 

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

Sun StorEdge SAN 4.0 support

 

 

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

Sun StorEdge SAN 4.1 support

 

 

 

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

Sun StorEdge SAN 4.2 support

 

 

 

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

Sun StorEdge SAN 4.4.6 support

 

 

 

 

 

 

 

 

checkmark

checkmark

Sun Cluster 3.0 support

 

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

Switchless configurations

 

 

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

checkmark

Internationalization support in all SUNWsecfg command line interface commands

 

 

 



checkmark



checkmark



checkmark



checkmark



checkmark



checkmark



checkmark

Storage Automated Diagnostic Environment 2.0 (SUNWstade)


checkmark


checkmark


checkmark

 

 

 

 

 

 

 

Storage Automated Diagnostic Environment 2.2 (SUNWstads)

 

 

 


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark

Solaris 8 Operating System host support (Solaris 8 07/01, Solaris 8 10/01, or Solaris 8 02/02 required)




checkmark




checkmark




checkmark




checkmark




checkmark




checkmark




checkmark




checkmark




checkmark




checkmark

Solaris 9 Operating System host support

 

 


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark


checkmark

Solaris 10 (SPARC) OS data host support

 

 

 

 

 

 

 

 


checkmark


checkmark

Multiplatform support for Windows 2000, NT, HP, IBM, and LINUX

 

 



checkmark



checkmark



checkmark



checkmark



checkmark



checkmark



checkmark



checkmark



System Requirements

For information about the Sun StorEdge 3900 and 6900 series hardware and software platform installation requirements, refer to the Sun StorEdge 3900 and 6900 Series 2.0 Installation Guide.

For information on the software packages and patches required to update to this release, refer to Installing the Storage Service Processor Upgrade.


Installing the Storage Service Processor Upgrade

This section includes information on how to perform a full image installation or an upgrade of the Storage Service Processor.



Note - To install version 2.3.7, version 2.3.6 must reside on the Storage Service Processor. Versions 2.3.4, 2.3.5, and 2.3.6 tar updates are available from SunServiceSM from the Service Partner Exchange web page:

https://spe.sun.com/spx/control/Login

If your site requires a reinstallation of the Storage Service Processor, first perform a full installation of version 2.3.1, then upgrade to 2.3.2, then 2.3.3, then 2.3.4, then 2.3.5, then 2.3.6, and, finally, upgrade to 2.3.7. See Full Installation of Version 2.3.1 and To Install the 2.3.7 Upgrade.




procedure icon  To Install the Full 2.3.1 Version

1. Read the complete SP_Image_CD_README.txt file.

2. Use the instructions printed on the CD insert, part number 818-0582-10.

Full Installation of Version 2.3.1

Ensure that you have a fully operational Storage Service Processor (Netratrademark X1 or SunFire V100 system) in the Sun StorEdge 3900 or 6900 series system. It is necessary to be connected through the console of the Storage Service Processor and logged in as the root user.



Note - Make sure that the hardware in the system has no faults and is fully functional before upgrading or downgrading the software on the system.





Note - Be sure that the user cmdadm is not logged into the Storage Service Processor being installed, because this causes the upgrade to fail.





Note - If you connect to the console of the Storage Service Processor to perform the installation, all reboots and messages can be seen during the installation.



The restoration of an entire Storage Service Processor version results in a single flat file system residing on a single partition. The Solaris JumpStarttrademark software mount point is the intended partition for staging the installation of the Storage Service Processor image.

The following is general information about the full image installation.

The following notes apply to all full version installations.


procedure icon  To Install the 2.3.7 Upgrade

The Upgrade path to image 2.3.5 is 2.3.1 to 2.3.2, then 2.3.2 to 2.3.3, then 2.3.3 to 2.3.4, then 2.3.4 to 2.3.5, then2.3.5 to 2.3.6, and 2.3.6 to 2.3.7.

The upgrade path to image 2.3.7 assumes that the Storage Service Processor has the 2.3.6 Storage Service Processor image revision installed. To verify this, log on to the Storage Service Processor and type: cat /etc/motd. The response should indicate that the revision is 2.3.6. If the revision reflects anything else, do not perform this upgrade. Instead, follow the upgrade path described above.

Upgrading to Version 2.3.x

To perform this upgrade, you must be connected via the console of the Storage Service Processor and logged in as the root user.



Note - Make sure that the hardware in the system has no faults and is fully functional before upgrading or downgrading the software on the system.





Note - Be sure that the user cmdadm is not logged into the Storage Service Processor being upgraded because this causes the upgrade to fail.





Note - You must read the complete README_Upgrade.txt file before performing an upgrade of the Storage Service Processor.



Other notes about the upgrade process are:

# /opt/SUNWstade/bin/config_solution

# /opt/SUNWstade/bin/ras_install

# /opt/SUNWstade/bin/config_solution


Known Issues and Bugs

This section contains the known issues and bugs associated with the Sun StorEdge 3900 and 6900 series.

Known Issues

There are no known issues with the Sun StorEdge 3900 and 6900 series 2.3.7 release.

Bugs

The following is a list of the priority 1, 2, and 3 bugs associated with Sun StorEdge 3900 and 6900 series systems. The Bug ID number is followed by the priority and severity of the bugs in parentheses.

Workaround: Use the workaround procedure given in Bug 4658578.

Workaround: Suspend Storage Automated Diagnostic Environment monitoring of the Sun StorEdge T3+ array that is being upgraded. After the firmware upgrade is complete, restart monitoring the Storage Automated Diagnostic Environment.

Workaround: Remove the shared memory semaphores using the ipcrm command as defined in the Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide in Chapter 9, "Restarting the slicd Daemon."

Workaround: Limit the number of disk pool pairs to 15 per virtualization engine pair.

Workaround: Run the luxadm failover manually.

Workaround: Use the HP-UX volume manager to slice the VLUN 0-7 into multiple volumes to achieve the same result.

Workaround: A link reset through luxadm -e forcelip command recovers or upgrades the Sun StorEdge network 2-Gbit Fibre Channel switch to a firmware of version 1.5.0 or greater.

Workaround: Use the instructions in the Sun StorEdge 3900 and 6900 Series 2.0 Reference and Service Manual to upgrade the firmware of the virtualization engine.

Workaround: To recover from this problem, disable the master controller from a telnet(1) session, allow the failover to occur, and then re-enable the controller. This causes the permissions and the group to reappear. A reset is required to fail the Sun StorEdge T3+ array back. You must also reset the host for it to fully recover its proper data paths.

Workaround: Disable the VERITAS Dynamic Multi-Pathing (VxDMP) volume manager.

Workaround: Do not allow more than 32 initiators to log onto the virtualization engine.

Workaround: Stop and restart slicd using the /etc/rc2.d/S98slicd command.

Workaround: After running the config_solution command, run the ras_install(1M) command, and then rerun the config_solution command.

Security Notes


Release Documentation

TABLE 2 lists the documentation for the Sun StorEdge 3900 and 6900 series systems. The suffix nn in a part number indicates that you should use the most current version. This documentation is available online at:


Service Contact Information

If you need help installing or using this product in the United States, call
1-800-USA-4SUN, or go to:

http://www.sun.com/service/contacting/index.html