Logical Domains 1.3 Administration Guide

Creating Default Services

You must create the following virtual default services initially to be able to use them later:

ProcedureCreate Default Services

  1. Create a virtual disk server (vds) to allow importing virtual disks into a logical domain.

    For example, the following command adds a virtual disk server (primary-vds0) to the control domain (primary).


    primary# ldm add-vds primary-vds0 primary
    
  2. Create a virtual console concentrator (vcc) service for use by the virtual network terminal server daemon (vntsd) and as a concentrator for all logical domain consoles.

    For example, the following command would add a virtual console concentrator service (primary-vcc0) with a port range from 5000 to 5100 to the control domain (primary).


    primary# ldm add-vcc port-range=5000-5100 primary-vcc0 primary
    
  3. Create a virtual switch service (vsw) to enable networking between virtual network (vnet) devices in logical domains.

    Assign a GLDv3-compliant network adapter to the virtual switch if each of the logical domains needs to communicate outside the box through the virtual switch.

    For example, the following command would add a virtual switch service (primary-vsw0) on network adapter driver nxge0 to the control domain (primary).


    primary# ldm add-vsw net-dev=nxge0 primary-vsw0 primary
    

    This command automatically allocates a MAC address to the virtual switch. You can specify your own MAC address as an option to the ldm add-vsw command. However, in that case, it is your responsibility to ensure that the MAC address specified does not conflict with an already existing MAC address.

    If the virtual switch being added replaces the underlying physical adapter as the primary network interface, it must be assigned the MAC address of the physical adapter, so that the Dynamic Host Configuration Protocol (DHCP) server assigns the domain the same IP address. See Enabling Networking Between the Control/Service Domain and Other Domains.


    primary# ldm add-vsw mac-addr=2:04:4f:fb:9f:0d net-dev=nxge0 primary-vsw0 primary
    
  4. Verify the services have been created by using the list-services subcommand.

    Your output should look similar to the following.


    primary# ldm list-services primary
    VDS
        NAME             VOLUME         OPTIONS          DEVICE
        primary-vds0
     
    VCC
        NAME             PORT-RANGE
        primary-vcc0     5000-5100
     
    VSW
        NAME             MAC               NET-DEV   DEVICE     MODE
        primary-vsw0     02:04:4f:fb:9f:0d nxge0     switch@0   prog,promisc