This table describes the enatest error messages, probable causes, and recommended actions.
Table 11-7 enatest Error Messages
|
Error Message |
Probable Cause(s) |
Recommended Action |
---|---|---|---|
6000 |
enclosure_name: Unable to access disk diskname (enclosure name, Front|Rear, Slot) |
Bad disk. |
Contact your authorized Sun service representative. |
6001 |
Unable to access any disk through host adapter: host adapter device |
Bad host adapter. |
Run SunVTS socaltest on the host adapter. |
6003 |
enclosure_name: Unable to access disk diskname (enclosure_name, Front|Rear, Slot) through Host adapter device name. This disk is still accessible through other path(s) |
Port A or B of the disk is faulty. |
Contact your authorized Sun service representative. |
6004 |
enclosure_name: Failed to determine the location of disk diskname |
Invalid device name. |
Contact your authorized Sun service representative. |
6005 |
enclosure_name: Could not access diskname (enclosure_name, Front|Rear, Slot) through Host adapter device name |
Host adapter is faulty. |
Contact your authorized Sun service representative. |
6006 |
enclosure_name: Disk diskname cannot be accessed through Host adapter device name |
Critical failure in the Interface Board (in the enclosure) through which this disk is accessed. |
Contact your authorized Sun service representative. |
6007 |
enclosure_name: Disk diskname cannot be accessed through Host adapter device name |
Interface Board (in the enclosure) through which this disk is accessed is not installed. |
|
6008 |
enclosure_name: Disk diskname cannot be accessed through Host adapter device name |
Critical failure (transmitter fault) in the GBIC module (in the enclosure) through which this disk is accessed. |
Contact your authorized Sun service representative. |
6009 |
enclosure_name: Disk diskname cannot be accessed through Host adapter device name |
Loss of light at the GBIC module (in the enclosure) through which this disk is accessed. |
Contact your authorized Sun service representative. |
Faulty cable. |
|||
Faulty GBIC module on the host side. |
|||
6013 |
enclosure_name: Could not access diskname (enclosure name, Front|Rear, Slot) through Host adapter device name |
Faulty GBIC module on host side. |
|
Bad cable connection. |
|||
6014 |
enclosure_name: Could not access diskname (enclosure name, Front|Rear, Slot) through Host adapter device name |
Faulty Host Adapter. |
|
Faulty GBIC on host side. |
|||
Faulty cable. |
|||
6015 |
enclosure_name: Could not access diskname through Host adapter device name |
Disk is not installed. |
|
6016 |
enclosure_name: Could not access diskname through Host adapter device name |
Disk detected to be installed, but may be bypassed or powered off. |
|
6017 |
enclosure_name: Disk diskname cannot be accessed through Host adapter device name |
Critical failure in the enclosure backplane through which this disk is accessed. |
Contact your authorized Sun service representative. |
6018 |
enclosure_name: Disk diskname cannot be accessed through Host adapter device name |
Enclosure backplane through which this disk is accessed is not installed. |
|
6019 |
enclosure_name: Disk diskname cannot be accessed through Host adapter device name |
GBIC module (in the enclosure) through which this disk is accessed is not installed. |
|
6020 |
enclosure_name: Cannot communicate with the enclosure via Host adapter device name |
Critical failure in the Interface Board (top/bottom one in enclosure). |
Contact your authorized Sun service representative. |
6021 |
enclosure_name: Cannot communicate with the enclosure via Host adapter device name |
Interface board (top or bottom) is not installed in the enclosure. |
|
6022 |
enclosure_name: Cannot communicate with the enclosure via Host adapter device name; possibly connected to location GBIC in the enclosure |
Critical failure (transmitter fault in the GBIC module in the enclosure). |
Contact your authorized Sun service representative. |
6023 |
enclosure_name: Cannot communicate with the enclosure via Host adapter device name; possibly connected to location GBIC in the enclosure |
Signal level too low at the GBIC module in the enclosure. |
Ensure the cables are properly connected. Contact your authorized Sun service representative. |
|
Faulty cable or cable disconnected. |
||
|
Faulty GBIC module on the host side. |
||
6024 |
enclosure_name: Cannot communicate with the enclosure via Host adapter device name |
GBIC module (location) is not installed in the enclosure. |
|
6026 |
enclosure_name: Failed to Restore|Toggle disk (Front|Rear, slot slot_number) state. Expected: Port A: Bypassed|Connected; Port B: Bypassed|Connected; Observed: Port A: Bypassed|Connected; Port B: Bypassed|Connected |
Error in Enclosure Services or Enclosure Element. |
Contact your authorized Sun service representative. |
6027 |
enclosure_name: Unable to access disk diskname (Front|Rear slot slot_number) through port A|B even after bringing the port online |
Error in Enclosure Services or Enclosure Element. |
Contact your authorized Sun service representative. |
6028 |
enclosure_name: Disk access succeeded for diskname (Front|Rear slot slot_number) through port A|B even after requesting that the port be bypassed |
Error in Enclosure Services or Enclosure Element. |
Contact your authorized Sun service representative. |
6035 |
enclosure_name: Cannot access enclosure through Host adapter device name |
Critical GBIC failure in the enclosure; location GBIC: disabled|enabled Signal: signal_level; Transmitter: Failed|OK; location GBIC: disabled|enabled Signal: signal_level; Transmitter: Failed|OK |
Contact your authorized Sun service representative. |
6036 |
enclosure_name: Critical condition detected in enclosure! |
|
Run this test in 'Functional' mode for more information. Contact your authorized Sun service representative. |
8001 |
Could'nt determine the host adapter through which diskname being accessed |
Software error. |
Contact your authorized Sun service representative. |
8003 |
Internal error |
Software error in test. |
Contact your authorized Sun service representative |
system error message. |
|||
8004 |
enclosure_name: Could not communicate with enclosure via Host adapter device name |
Bad connection. |
Ensure the cables are properly connected. Contact your authorized Sun service representative. |
8005 |
Could not communicate with the enclosure |
Faulty connection. |
Ensure the cables are properly connected. Run SunVTS socaltest to verify the host adapter. Contact your authorized Sun service representative. |