SunVTS 3.0 Test Reference Manual

scitest Error Messages

Table 30-4 scitest Error Messages

 

Error Message 

Probable Cause(s) 

Recommended Action 

4001

Unable to communicate from string

SCI adapter failure or no cable connected. 

Check cable connections.  

Replace the SCI adaptor. 

4002

Can not access /etc/sma.ip file. "I WILL STOP TESTING SCI INTERFACES"

/etc/sma.ip is missing, or the cluster is not configured, or this is an old cluster version.

Use sm_config to configure the cluster. Restore the files from a backup tape. Specify the cluster machines in the target host of test options before running the test.

6000

RPC broadcast failure error_message

 

 

6001

Unable to resolve host_name ethernet address

 

 

6002

No ICMP echo reply from string

SCI adaptor failure or no cable connected. 

Check cable connections.  

Replace the SCI adaptor. 

 

6003

ICMP echo reply incorrect length from host_name, exp data obs data

 

 

6004

ICMP echo reply length number from host_name, data mismatch at byte number, exp value obs value

 

 

6005

Unable to find any test target

 

 

8000

Unable to open device_name error_message

 

 

8001

Bad ioctl name error_message

 

 

8002

Unable to allocate number bytes of memory error_message

 

 

8003

System call name returned value error_message

 

 

8004

Unable to map network entry for host_name

 

 

8006

Failed to allocate number bytes of swap space for configuration

 

 

8007

dl_primitive response = value

 

 

8008

dl_ok_ack: short response

 

 

8009

dl_phys_addr_ack: short response

 

 

8010

Invalid Argument string

 

 

8011

Interface device_name not configured in system

 

 

8012

SCITEST can not open/read /etc/sma.ip