Check Link Status

  1. Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this procedure.

    See Installation Sequence.

  2. On the management controller, determine the state of the links:

    # listlinkup
    • If the link for a connector is reported as Not present, there is no cable attached or the link at either end of the cable is down.

    • If a port is down, use the enableswitchport command to bring the port up. Alternatively, use the i4reset command to reset the entire switch chip. See Enable a Switch Chip Port and Reset the Switch Chip.

  3. Verify the InfiniBand fabric.

    See Verifying the InfiniBand Fabric.

Related Information