Exit Print View

Sun Datacenter InfiniBand Switch 72 Topic Set

Get PDF Book Print View
 

Document Information

Using This Documentation

Related Documentation

Documentation, Support, and Training

Documentation Feedback

User Guide

Installing the Switch

Administering the Switch

Servicing the Switch

Reference

Understanding the Commands

Understanding Hardware Commands

checkboot Command

checkpower Command

checkvoltages Command

connector Command

disablesm Command

disableswitchport Command

enablesm Command

enableswitchport Command

env_test Command

getfanspeed Command

getportstatus Command

i4reset Command

listlinkup Command

managementreset Command

nm2version Command

readchfru Command

setlinkspeed Command

setsmpriority Command

showtemps Command

showunhealthy Command

Understanding InfiniBand Commands

ibaddr Command

ibcheckerrors Command

ibchecknet Command

ibchecknode Command

ibcheckport Command

ibcheckportstate Command

ibcheckportwidth Command

ibcheckstate Command

ibcheckwidth Command

ibclearcounters Command

ibclearerrors Command

ibdatacounters Command

ibdatacounts Command

ibdiagnet Command

ibdiagpath Command

ibhosts Command

ibnetdiscover Command

ibnodes Command

ibportstate Command

ibroute Command

ibstatus Command

ibswitches Command

ibsysstat Command

ibtracert Command

opensm Command

opensmd Daemon

osmtest Command

perfquery Command

saquery Command

sminfo Command

smpdump Command

smpquery Command

Index

env_test Command

Displays environmental status.

Syntax

env_test

Description

This hardware command performs a series of hardware and environmental tests of the switch. This command is an amalgamation of the following commands:

The command output provides voltage and temperature values, pass-fail results, and error messages.

Example

The following example shows how to display the hardware and environmental status of the switch with the env_test command.

# env_test
NM2 Environment test started:
Starting Voltage test:
Voltage ECB OK
Measured 3.3V Main = 3.28 V
Measured 3.3V Standby = 3.40 V
Measured 12V = 12.06 V
Measured 5V = 5.10 V
Measured VBAT = 3.17 V
Measured 1.8V = 1.78 V
Measured 1.2V Standby = 1.21 V
Measured 1.8V Standby = 1.80 V
Measured 2.5VA = 2.51 V
Measured 2.5VB = 2.51 V
Measured 1.2VA = 1.22 V
Measured 1.2VB = 1.22 V
Measured 1.2VC = 1.21 V
Measured 1.2VD = 1.21 V
Measured 1.2VB = 1.21 V
Measured 1.2VE = 1.21 V
Measured 1.2VF = 1.21 V
Voltage test returned OK
Starting PSU test:
PSU 0 present
PSU 1 present
PSU test returned OK
Starting Temperature test:
Back temperature 23.00
Front temperature 32.62
ComEx temperature 26.12
I4-A temperature 55, maxtemperature 56
I4-B temperature 48, maxtemperature 49
I4-C temperature 53, maxtemperature 53
I4-D temperature 48, maxtemperature 49
I4-E temperature 53, maxtemperature 54
I4-F temperature 53, maxtemperature 54
Temperature test returned OK
Starting FAN test:
Fan 0 running at rpm 12433
Fan 1 running at rpm 12311
Fan 2 running at rpm 12311
Fan 3 running at rpm 12433
Fan 4 running at rpm 12433
FAN test returned OK
Starting Connector test:
Connector test returned OK
Starting I4 test:
I4-A OK
I4-B OK
I4-C OK
I4-D OK
I4-E OK
I4-F OK
All I4s OK
I4 test returned OK
NM2 Environment test PASSED
#