System Administration Guide: Basic Administration

SPARC: Troubleshooting SCSI Configuration Problems

This section provides error messages and possible solutions for troubleshooting SCSI configuration problems. For more information on troubleshooting SCSI configuration problems, see cfgadm(1M).

Error Message

cfgadm: Component system is busy, try again: failed to offline:
     device path
          Resource              Information
     ------------------  --------------------------
     /dev/dsk/c1t0d0s0   mounted filesystem "/file-system"
Cause

You attempted to remove or replace a device with a mounted file system.

Solution

Unmount the file system that is listed in the error message and retry the cfgadm operation.

If you use the cfgadm command to remove a system resource, such as a swap device or a dedicated dump device, an error messages similar to the following is displayed if the system resource is still active.

Error Message

cfgadm: Component system is busy, try again: failed to offline:
     device path
          Resource              Information
     ------------------  --------------------------
     /dev/dsk/device-name   swap area
Cause

You attempted to remove or replace one or more configured swap areas.

Solution

Unconfigure the swap areas on the device that is specified and retry the cfgadm operation.

Error Message

cfgadm: Component system is busy, try again: failed to offline:
     device path
          Resource              Information
     ------------------  --------------------------
     /dev/dsk/device-name   dump device (swap)
Cause

You attempted to remove or replace a dump device that is configured on a swap area.

Solution

Unconfigure the dump device that is configured on the swap area and retry the cfgadm operation.

Error Message

cfgadm: Component system is busy, try again: failed to offline:
     device path
          Resource              Information
     ------------------  --------------------------
     /dev/dsk/device-name   dump device (dedicated)
Cause

You attempted to remove or replace a dedicated dump device.

Solution

Unconfigure the dedicate dump device and retry the cfgadm operation.