Sun Cluster 3.1 - 3.2 Hardware Administration Manual for Solaris OS

Determining Campus Cluster Connection Technologies

This section lists example technologies for the private cluster interconnect and for the data paths and their various distance limits. In some cases, it is possible to extend these limits. For more information, ask your Sun representative.

Cluster Interconnect Technologies

The following table lists example node-to-node link technologies and their limitations.

Table 7–2 Campus Cluster Interconnect Technologies and Distance Limits

Link Technology 

Maximum Distance 

Comments 

100 Mbps Ethernet 

100 meters per segment 

unshielded twisted pair (UTP) 

1000 Mbps Ethernet 

100 meters per segment 

UTP 

1000 Mbps Ethernet 

260 meters per segment 

62.5/125 micron multimode fiber (MMF) 

1000 Mbps Ethernet 

550 meters per segment 

50/125 micron MMF 

1000 Mbps Ethernet (FC) 

10 kilometers at 1 Gbps 

9/125 micron single-mode fiber (SMF) 

DWDM 

200 kilometers and up 

 

Other 

 

Consult your Sun representative 

Always check your vendor documentation for technology-specific requirements and limitations.

Storage Area Network Technologies

The following table lists example link technologies for the cluster data paths and the distance limits for a single interswitch link (ISL).

Table 7–3 ISL Limits

Link Technology 

Maximum Distance 

Comments 

FC short-wave gigabit interface converter (GBIC) 

500 meters at 1 Gbps 

50/125 micron MMF 

FC long-wave GBIC 

10 kilometers at 1 Gbps 

9/125 micron SMF 

FC short-wave small form-factor pluggable (SFP) 

300 meters at 2 Gbps 

62.5/125 micron MMF 

FC short-wave SFP 

500 meters at 2 Gbps 

62.5/125 micron MMF 

FC long-wave SFP 

10 kilometers at 2 Gbps 

9/125 micron SMF 

DWDM 

200 kilometers and up 

 

Other 

 

Consult your Sun representative