JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
SPARC T3-1 Server HTML Document Collection
search filter icon
search icon

Document Information

Using This Documentation

Related Documentation

Feedback

Support and Accessibility

Installation

Preparing for the Installation

Installation Task Overview

Server Overview

Server Specifications

Front Panel Components

Front Panel System LEDs and Buttons

Rear Panel Components

Rear Panel System LEDs and Button

Server Handling Precautions

ESD Precautions

Tools Needed for Installation

Optional Component Installation

Installing the Server

Stabilize the Rack

Slide Rail Assembly Overview

Install the Screw-Mount Slide Rail Assemblies

Install the Snap-In Slide Rail Assemblies

Insert and Lock the Server in the Rack

Install the Cable Management Arm

Verify Correct Operation of the Slide Rails and the CMA

Connecting the Server Cables

Cabling Requirements

Connect the SER MGT Port Cable

Connect the NET MGT Port Cable

Connect the Ethernet Network Cables

Connect Other I/O Cables

Prepare the Power Cords

Cable Management Overview

Secure the Server Cables in the CMA

Powering On the Server For the First Time

Initial Power-On Tasks Overview

Oracle ILOM System Console Overview

Connect a Terminal or Emulator to the SER MGT Port

Power On the Server for the First Time

Verify System Functionality

Assign a Static IP Address to the Service Processor

Administration

Understanding System Administration Resources

Oracle ILOM Overview

Platform-Specific Oracle ILOM Features

Oracle Solaris OS Overview

OpenBoot Overview

Oracle VM Server for SPARC Overview

Multipathing Software

Hardware Management Pack Overview

Source for Downloading Hardware Management Pack Software

Hardware Management Pack Documentation

Accessing the Server

Log In to Oracle ILOM

Log In to the System Console

Display the ok Prompt

Display the Oracle ILOM -> Prompt

Use a Local Graphics Monitor

Oracle ILOM Remote Console

Controlling the Server

Power On the Server

Power Off the Server

Reset the Server From the Oracle Solaris OS

Reset the Server From Oracle ILOM

Reset the SP to Default Values

Configuring Hardware RAID

Hardware RAID Support

Important Hardware RAID Guidelines

Disk Zones for SPARC T3-1 Servers With Sixteen-Disk Backplanes

Displaying Disk Zone Information

Enabling and Disabling Disk Zoning In the Field

Prepare to Use the FCode Utility

FCode Utility Commands

Create a Hardware RAID Volume

Hot Spare Drives in RAID Volumes (LSI)

Determining If a Drive Has Failed

RAID Drive Replacement Strategies

Locate Device Paths

Changing Server Identification Information

Change Customer FRUdata Information

Change System Identifier Information

Configuring Policy Settings

Specify Cooldown Mode

Restore Host Power State at Restart

Specify Host Power State at Restart

Disable or Re-Enable Power-On Delay

Specify Parallel Boot of the SP and Host

Configure Host Behavior With the Keyswitch State

Configuring Network Addresses

SP Network Address Options

Disable or Re-Enable Network Access to the SP

Display the DHCP Server IP Address

Display the Host MAC Address

Using an In-band Connection to the SP

Configuring Boot Mode

Boot Mode Overview

Configure the Host Boot Mode of Oracle VM Server for SPARC

Change the Host Boot Mode Behavior at Reset

Manage the Host Boot Mode Script

Display Host Boot Mode Expiration Date

Override OpenBoot PROM Settings to Reset the Server

Configuring Server Behavior at Restart

Specify Behavior When the Host Resets

Specify Behavior When the Host Stops Running

Set the Boot Timeout Interval

Specify Behavior at Boot Timeout

Specify Behavior if Restart Fails

Specify Maximum Restart Attempts

Configuring Devices

Unconfigure a Device Manually

Reconfigure a Device Manually

Monitoring the Server

Monitoring Faults

Enabling Automatic System Recovery

Display Server Components

Locate the Server

Updating the Firmware

Display the Firmware Version

Update the Firmware

Display OpenBoot Version

Display POST Version

Identifying WWN-Designated SAS2 Devices

World Wide Name Syntax

probe-scsi-all Output Example (SPARC T3-1, Eight-Disk Backplane)

probe-scsi-all Output Example (SPARC T3-1, Sixteen-Disk Backplane)

probe-scsi-all Output Example (SPARC T3-4)

Identify a Disk Slot Using probe-scsi-all (OBP)

Identify a Disk Slot Using prtconf (Oracle Solaris, Onboard Controllers)

Identify a Disk Slot Using prtconf (Oracle Solaris, Single Initiator)

WWN Syntax in an OS Installation on a Specific Device

WWN Syntax in an OS Installation on a RAID Volume

Service

Identifying Server Components

Front Components

Rear Components

Infrastructure Boards in the SPARC T3-1 Server

Internal System Cables

Illustrated Parts Breakdown

Understanding Hard Drive Data Cable Routing

Detecting and Managing Faults

Diagnostics Overview

Diagnostics Process

Interpreting Diagnostic LEDs

Managing Faults (Oracle ILOM)

Understanding Fault Management Commands

Interpreting Log Files and System Messages

Checking if Oracle VTS Software Is Installed

Managing Faults (POST)

Managing Faults (PSH)

Managing Components (ASR)

Preparing for Service

Safety Information

Tools Needed for Service

Find the Chassis Serial Number

Locate the Server

Understanding Component Replacement Categories

Removing Power From the System

Positioning the System for Service

Accessing Internal Components

Servicing DIMMs

Memory Fault Handling Overview

Locate a Faulty DIMM Using the Remind Button

Identify Faulty DIMMs Using the show faulty Command

Remove a DIMM

Install a DIMM

Increase System Memory With Additional DIMMs

Verify DIMM Functionality

Memory Configuration Guidelines

Servicing HDDs

HDD Hot-Pluggable Capabilities

Hard Drive Slot Configuration Reference

Hard Drive LEDs

Remove a Hard Drive

Install a Hard Drive

Verify the Functionality of a Hard Drive

Servicing the DVD/USB Assembly

DVD/USB Assembly Overview

Remove the DVD/USB Assembly

Install the DVD/USB Assembly

Servicing the Power Supplies

Power Supply Hot-Swap Capabilities

Power Supply LEDs

Locate a Faulty Power Supply

Remove a Power Supply

Install a Power Supply

Verify the Functionality of a Power Supply

Remove or Install a Power Supply Filler Panel

Servicing the Power Distribution Board

Power Distribution Board Overview

Remove the Power Distribution Board

Install the Power Distribution Board

Servicing the Power Supply Backplane

Power Supply Backplane Overview

Remove the Power Supply Backplane

Install the Power Supply Backplane

Servicing the Connector Board

Connector Board Overview

Remove the Connector Board

Install the Connector Board

Servicing PCIe and PCIe/XAUI Risers

Remove a PCIe or PCIe/XAUI Riser

Install a PCIe or PCIe/XAUI Riser

Servicing PCIe Cards

PCIe Card Configuration Reference

Remove a PCIe or XAUI Card

Install a PCIe or XAUI Card

Servicing SAS PCIe RAID HBA Cards

Remove a SAS PCIe RAID HBA Card

Install a SAS PCIe RAID HBA Card

Servicing the Service Processor

Service Processor Overview

Remove the Service Processor

Install the Service Processor

Servicing the System Battery

Replace the System Battery

Verify the System Battery

Servicing Fan Modules

Fan Configuration Reference

Fan Module LEDs

Locate a Faulty Fan Module

Remove a Fan Module

Install a Fan Module

Servicing the Fan Power Board

Fan Power Board Overview

Remove the Fan Power Board

Install the Fan Power Board

Servicing the System Configuration PROM

System Configuration PROM Overview

Remove the System Configuration PROM

Install the System Configuration PROM

Verify the System Configuration PROM

Servicing the HDD Cage

Hard Drive Cage Overview

Remove the Hard Drive Cage

Install the Hard Drive Cage

Servicing the HDD Backplane

Hard Drive Backplane Overview

Remove the Hard Drive Backplane

Install the Hard Drive Backplane

Servicing the Front Panel Light Pipe Assemblies

Front Panel Light Pipe Assemblies Overview

Remove the Front Panel Light Pipe Assembly (Right or Left)

Install the Front Panel Light Pipe Assembly (Right or Left)

Servicing the Motherboard Assembly

Motherboard Servicing Overview

Remove the Motherboard Assembly

Install the Motherboard Assembly

Returning the Server to Operation

Install the Top Cover

Reinstall the Server in the Rack

Return the Server to the Normal Rack Position

Reconnect the Power Cords

Power On the Server (start /SYS Command)

Power On the Server (Power Button)

Glossary

Index

Remove the Front Panel Light Pipe Assembly (Right or Left)


Note - This is a cold service procedure that must be performed by qualified service personnel. See Cold Service, Replaceable by Authorized Service Personnel for more information about this category of service procedures.



Caution

Caution - The server must be fully shut down and the power cords disconnected.



Caution

Caution - This procedure involves handling circuit boards that are extremely sensitive to static electricity. Ensure that you follow ESD preventative practices to avoid damaging the circuit boards.



Hot

Caution - Components inside the chassis might be hot. Use caution when servicing components inside the chassis.


  1. Remove the hard drive cage.

    See Remove the Hard Drive Cage.

  2. Remove the three screws that secure the left or right light pipe assembly mounting plate to the hard drive cage.

    This step is identical for both left and right assemblies.


    image:Graphic showing removal of the front control panel light pipe assembly.

    The next steps depend on whether you are removing the right or left light pipe assembly.

    • For the right light pipe assembly, go to Step 3.

    • For the left light pipe assembly, go to Step 4

  3. Remove the right light pipe assembly from its metal plate.

    This light pipe assembly is secured by two small hook-shaped clips that fit through holes in the metal plate and grip the other side of the plate. Two locator pins close to the front of the light pipe assembly help align the light pipes with the holes in the front panel flange.

    1. Use your thumb and index finger to grasp the light pipes near the two locator pins and gently bend the light pipes away from the mounting plate. Pull them just far enough to disengage the two hook-shaped clips from the slots.
    2. When the clips release their hold on the plate, remove the light pipe assembly from the metal plate.
  4. Remove the left light pipe assembly from its metal plate.

    This light pipe assembly is secured by two small hook-shaped clips that fit through a pair of rectangular holes in the metal plate. These holes are to the left of a curved plastic spring. The hooks grip the plate through a corresponding pair of smaller holes to the right.


    Note - The curved plastic spring partially covers the hole used by the hook on the upper clip. This reduces access to the upper hook.


    1. Using the tip of a pointed object, such as the end of a paper clip or a stylus, push the hook end of the lower clip out of its hole. This is the hole that is not covered by the curved plastic spring.

      Tip - If possible, leave this pointed object in the lower hole to prevent the hook from sliding back in and use a different tool for the upper hook.


    2. Repeat Step a for the upper hook.
    3. When both clip hooks are out of their holes, slide the light pipe assembly toward the rear of the metal plate and remove it.
Related Information