Site Planning

Sun SPARC Enterprise T5140 and T5240 Servers Site Planning Guide

Physical Specifications

Minimum Clearance for Service Access

Environmental Specifications

Power Source Requirements

Acoustic Noise Emissions

Agency Compliance Specifications

Operating Environment Requirements

Installation

Preparing for Installation

Server Overview

Server Handling Precautions

Input Power Information and Precautions

Tools and Equipment Needed

Optional Component Installation

ESD Precautions

Installation Overview

Prepare for Installation

Install the Hardware

Configure the Service Processor

Configure the Host Software

Cabling Notes for Both Servers

Port, Connector, and LED Locations for Both Servers

Slide Rail Assembly Notes for Both Servers

Cable Management Notes for Both Servers

Installing the Sun SPARC Enterprise T5140 and T5240 Servers

Installing the Servers in a Rack

Installing the Cable Management Arm for Both Servers

Connecting the Server Cables for Both Servers

Managing Cables With the CMA

Powering On the System

Powering On the System for the First Time

Enable the Service Processor Network Management Port

Logging Into the Service Processor

Using the Service Processor for Common Operations

Booting the Solaris Operating System

Verifying System Functionality

Updating the Firmware

flashupdate command

Update the Firmware

Selecting a Boot Device

Boot Device Selection Overview

Select a Boot Device

Installing the Servers With the Express Rail Rackmounting Kit

Slide Rail Assembly Notes for the Express Rail Rackmounting Kit

Install the Slide Rail Assemblies

Insert and Lock the Server in the Rack

Dismounting the Server

Assembling and Installing DC Power Cables for the Sun SPARC Enterprise T5140 Server

Requirements for Servers With DC Input Power

DC Supply and Ground Conductor Requirements

Overcurrent Protection Requirements

Assembling and Installing the DC Input Power Cables

Assembling and Installing DC Power Cables for the Sun SPARC Enterprise T5240 Server

Requirements for Servers With DC Input Power

DC Supply and Ground Conductor Requirements

Overcurrent Protection Requirements

Assembling and Installing the DC Input Power Cables

Assemble the DC Input Power Cables

Connect the DC Input Power Cords to the Server

Administration

Communicating With the System

ILOM Overview

Log In to ILOM

Log In to the System Console

Display the ok Prompt

Display the ILOM ->Prompt

Use a Local Graphics Monitor

Performing Common Tasks

Power On the System

Power Off the System

Reset the System

Update the Firmware

Managing Disks

Hardware RAID Support

Creating Hardware RAID Volumes

Delete a Hardware RAID Volume

Hot-Plug a Mirrored Disk

Hot-Plug a Nonmirrored Disk

Disk Slot Numbers

Managing Devices

Unconfigure a Device Manually

Reconfigure a Device Manually

Devices and Device Identifiers

Sun SPARC Enterprise T5x40 Device Tree

Multipathing Software

Handling Faults

Discovering Faults

Bypassing Minor Faults

Clear a Fault

Managing Logical Domains Software

Logical Domains Software

Logical Domain Configurations

OpenBoot Configuration Variables

OpenBoot Configuration Variables on the SCC

Remote Management (ILOM 3.0)

Understanding ILOM for the Sun SPARC Enterprise T5140 and T5240 Servers

ILOM Overview

Platform-Specific ILOM Features

ILOM Features Not Supported

Managing the Host

Reset the Host

Managing Host Boot Mode

Viewing and Configuring Host Control Information

Managing System User Interactions

Managing the Service Processor

Storing Customer Information

Display Console History (CLI)

Change Console Escape Characters (CLI)

Changing Configuration Policy Settings

Managing Network Access

Managing Devices

Specify Host Behavior With the Virtual Keyswitch

Specify Host Behavior With the Virtual Keyswitch (Web Interface)

Discover IPMI Sensors and Indicators

Sensors on Sun SPARC Enterprise T5140 and T5240 Servers

Indicators on the Sun SPARC Enterprise T5140 and T5240 Servers

Discover ALOM Compatibility Information

ALOM CMT Compatibility Shell

ALOM CMT Variable Comparison

Event Messages Available Through the ALOM Compatibility Shell

Service

Identifying Server Components

Infrastructure Boards in Sun SPARC Enterprise T5140 Servers

Infrastructure Boards in Sun SPARC Enterprise T5240 Servers

Internal System Cables for Sun SPARC Enterprise T5140 Servers

Internal System Cables for Sun SPARC Enterprise T5240 Servers

Front Panel Controls and Indicators on Sun SPARC Enterprise T5140 Servers

Rear Panel Components and Indicators on Sun SPARC Enterprise T5140 Servers

Front Panel Controls and Indicators on Sun SPARC Enterprise T5240 Servers

Rear Panel Components and Indicators on Sun SPARC Enterprise T5240 Servers

Status LEDs for Ethernet Ports and the Network Management Port

Detecting and Managing Faults

Diagnostic Tools Overview

Diagnostics Tools Quick Reference

LED Overview

Detecting Faults With ILOM

Detecting Faults With POST

Managing Faults Using the PSH Feature

Viewing Solaris OS Messages

Managing Components With Automatic System Recovery Commands

Detecting Faults Using SunVTS Software

Preparing to Service the System

General Safety Information

Essential Tools

Find the Chassis Serial Number

Removing Power From the System

Positioning the System for Servicing

Accessing Internal Components

Servicing Hard Drives

Hard Drive Servicing Overview

Hard Drive LEDs

Remove a Hard Drive

Install a Hard Drive

Four-Drive Capable Backplane Configuration Reference

Eight-Drive Capable Backplane Configuration Reference

Sixteen-Drive Capable Backplane Configuration Reference

Servicing Motherboard Components

Servicing FB-DIMMs

Servicing the Air Duct

Servicing PCIe/XAUI Risers

Servicing the Battery

Servicing the SCC Module

Servicing the Memory Mezzanine Assembly (Sun SPARC Enterprise T5240)

Servicing the Motherboard Assembly

Servicing Fan Modules

Fan Module Overview

Remove a Fan Module

Install a Fan Module

Servicing Power Supplies

Power Supplies Overview

Remove a Power Supply

Install a Power Supply

Power Supply Configuration Reference

Servicing Boards and Components

Important Safety Instructions

Servicing DVD/USB Modules

Servicing Fan Power Boards

Servicing the Hard Drive Cage

Servicing the Hard Drive Backplane

Servicing Front Control Panel Light Pipe Assemblies

Servicing Power Distribution Boards

Servicing Power Supply Backplanes (Sun SPARC Enterprise T5240 Servers)

Servicing Paddle Cards

Returning the Server to Operation

Install the Top Cover

Reinstall the Server in the Rack

Return the Server to the Normal Rack Position

Connect Power Cords to the Server

Power On the Server Using the poweron Command

Power On the Server Using the Front Panel Power Button

Identifying FRUs in Sun SPARC Enterprise T5140 Servers

Motherboard Components in Sun SPARC Enterprise T5140 Servers

I/O Components in Sun SPARC Enterprise T5140 Servers

Power Distribution/Fan Module Components in Sun SPARC Enterprise T5140 Servers

Internal Cables for Onboard SAS Controller Cards in Sun SPARC Enterprise T5140 Servers

HDD Data Cable Routing for SAS RAID Controller Cards in Four-Disk Capable Sun SPARC Enterprise T5140 Servers

HDD Data Cable Routing for SAS RAID Controller Cards in Eight-Disk Capable Sun SPARC Enterprise T5140 Servers

Identifying FRUs in Sun SPARC Enterprise T5240 Servers

Motherboard Components in Sun SPARC Enterprise T5240 Servers

Memory Mezzanine Components in Sun SPARC Enterprise T5240 Servers

I/O Components in Sun SPARC Enterprise T5240 Servers

Power Distribution/Fan Module Components in Sun SPARC Enterprise T5240 Servers

Internal Cables for Onboard SAS Controller Cards in Sun SPARC Enterprise T5240 Servers

HDD Data Cable Routing for SAS RAID Controller Cards in Sun SPARC Enterprise T5240 Servers

Index

Assemble the DC Input Power Cables

Before You Begin

The following procedure describes how to assemble the DC input power cables for Oracle’s Sun SPARC Enterprise T5240 server.

Assemble one cable for each DC power supply in your server.

Before you begin the installation procedure, verify that the required conditions described in the following table have been satisfied.

Prerequisite Condition
Responsible Party
Install a DC power source that meets the server’s input power specifications.
Customer
Secure DC power cables that meet the server’s power cabling specifications.
Customer
Attach the DC input plug to the DC input power cables. The input plug is provided in the server’s shipping kit.
Customer
  1. Turn off power from the DC power source using the circuit breakers.

    Caution

    Caution - Do not proceed with these instructions until you have turned off the power from the DC power source through the circuit breakers.


  2. Identify the parts that you will use to assemble the DC input power cables.

    For each cable, you need a DC input plug, cage clamp tool or small screwdriver. These items are provided in the shipping kit that came with your server (DC models only).


    Figure 46 DC Connection Parts

    Figure showing DC connection parts.

    Figure Legend

    1 DC input plugDC input plug

    2 cage clamp operating toolCage clamp operating tool or small screwdriver

  3. Locate the three wires coming from your DC power source that will be used in the connection to your unit:
    • -48V or -60V (negative terminal)
    • Chassis ground
    • -48V or -60V Return (positive terminal)

      Note - Depending on the DC power source, the -48V or -60V (negative terminal) might be marked with a minus (-) symbol. The -48V or -60V Return (positive terminal) might be marked with a positive (+) symbol.


  4. Strip 1/2 in. (13 mm) of insulation from each of the wires coming from the DC power source.

    Do not strip more than 1/2 in. (13 mm) from each wire. Doing so leaves uninsulated wire exposed from the DC connector after the assembly is complete.


    Figure 47 Stripping the Insulation From the Wire

    Figure showing the amount of insulation to strip from the wire (1/2 inch, 13mm).

    Figure Legend

    1 1/2 in. (13 mm)

  5. Open the cage clamp by inserting the cage clamp tool (or small screwdriver) into the rectangular hole directly above the hole in the DC input plug where you want to insert the first wire, and push in to open the cage clamp.

    Figure 48 Opening the Cage Clamp Using the Cage Clamp Tool

    Figure showing how to open the cage clamp using the tool.
  6. Feed the exposed section of the appropriate wire into the round plug hole in the DC input plug.

    Figure 49 Connector Wiring Assignments

    Figure showing how to assemble the DC input power cable.

    Figure Legend

    1 From -48V or -60V

    2 From Chassis ground (green/yellow)

    3 From -48V or -60V Return


    Note - If you need to remove a wire from the DC input plug, insert the cage clamp operating tool or a small screwdriver into the slot directly above the wire and push in. Pull the wire from the DC input plug.


  7. Remove the cage clamp tool to secure the wire.
  8. Repeat the procedures for the other two wires to complete the assembly of the DC input power cable.
  9. Repeat this procedure to create as many DC input power cables as you need for your unit.
Related Information