JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Oracle Integrated Lights Out Manager (ILOM) 3.x

Supplement for the Sun Blade 6000 Modular System

search filter icon
search icon

Document Information

Using This Documentation

Downloading Chassis Firmware

Documentation and Feedback

About This Documentation

About Oracle ILOM on the Modular System

Oracle ILOM Overview

Oracle ILOM Features Specific to the Modular System

Modular System Power Usage

Fan Speed Control

Modular System Oracle ILOM CLI Targets

Sun Blade Zone Manager

Oracle ILOM Documentation

Monitoring System Health

Chassis Sensors Overview

Monitoring System Health With ILOM 3.1

Oracle ILOM 3.0 Sensor Information

Sensor Types

Display Sensor Readings in Oracle ILOM 3.0

Display Sensor Readings (Web Interface)

Display Sensor Readings (CLI)

Chassis Sensors in Oracle ILOM 3.0

Fan Sensors in Oracle ILOM 3.0

Power Supply Sensors in Oracle ILOM 3.0

NEM Sensors in Oracle ILOM 3.0

Server Module Sensors in Oracle ILOM 3.0

SNMP and PET Reference Information

SNMP Traps

PET Event Messages

Index

Fan Sensors in Oracle ILOM 3.0

The modular system chassis contains six fan modules, numbered FM0 to FM5. Each module contains two fans numbered F0 to F1.


Note - For ILOM 3.1, replace /CH with /SYSTEM.


Sensor
Threshold
Direction
Event
Description
/CH/FMn/Fn/TACH
Lower nonrecoverable
Assert
Yes
Fan speed has decreased below lower nonrecoverable threshold.This event indicates that the fan has failed or has been removed.
Lower noncritical
Deassert
Yes
Fan speed has returned to normal from lower nonrecoverable.This event indicates that the fan has returned to normal or has been replaced.
Sensor
Reading
State
Event
Description
/CH/FMn/ERR
0x0001
Predictive Failure Deasserted
No
Indicates that the fan module has not failed.
0x0002
Predictive Failure Asserted
Yes
Indicates that the fan module has failed.