JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Oracle Hardware Management Pack 2.2.x HTML Documentation Collection
Oracle Technology Network
Library
PDF
Print View
Feedback
search filter icon
search icon

Document Information

Using This Documentation

Install Guide

Management Agents User's Guide

CLI Tools User's Guide

Oracle Server CLI Tools Overview

CLI Tools Command Syntax and Conventions

CLI Tools Command Syntax

CLI Tools Device-Naming Convention

Using the biosconfig Tool

biosconfig Overview

biosconfig Requirements

biosconfig Terminology

Device Terminology Used by biosconfig

Device Name Examples

Editing XML Files

biosconfig Command Overview

biosconfig for Oracle Solaris OS

biosconfig for Windows

How to Install the biosconfig Sun System Management Driver on Windows 2008 R2 and Windows 2008 64–bit

How to Uninstall the biosconfig Sun System Management Driver on Windows 2008 R2 and Windows 2008 64–bit

Viewing biosconfig Command Options and Version Information

How to View biosconfig Command Options

How to View biosconfig Version Information

Configuring the Device Boot Order

Methods for Changing the Boot List

How to Set the First Boot Device for the Next Boot

How to Make a Persistent Change to Boot Order

How to Change Boot Order Based on the PCI Bus, Device, or Function

Configuring the BIOS CMOS

How to Capture the BIOS CMOS Golden Image

How to Apply the BIOS CMOS Golden Image

Configuring Individual CMOS Settings

Static and Dynamic CMOS Settings

How to Configure a Static CMOS Setting

How to Configure a Dynamic Setting

Commands That Produce Unrelated, Innocuous, Extra Output

Using the ubiosconfig Tool

ubiosconfig Command Overview

export Subcommand

import Subcommand

list Subcommand

cancel Subcommand

reset Subcommand

Using the fwupdate Tool

fwupdate Overview

fwupdate Command Prerequsite

Downloading Firmware Files

Automatic and Manual Update Modes

Host-to-ILOM Interconnect

fwupdate Command Overview

fwupdate Command-Line Interface

Automatic Mode fwupdate Command-Line Interface

Manual Mode fwupdate Command-Line Interface

list Subcommand

update Subcommand

Automatic Mode update Subcommand

Manual Mode update Subcommand

reset Subcommand

fwupdate Network Based Service Processor Options

How to Use fwupdate to Update an Oracle ILOM Service Processor

Execution Summary

Using the raidconfig Tool

raidconfig Overview

raidconfig Requirements

raidconfig Command Overview

list Subcommand

list Subcommand Overview

Brief Listing Example

Brief Listing of a Disk Example

Detailed Listing Example

create raid Subcommand

How To Create a RAID Volume

delete raid Subcommand

How To Delete a RAID Volume

add disk Subcommand

How to Add a Disk

remove disk Subcommand

How to Remove a Disk from a RAID Volume

add spare Subcommand

How to Add a Spare

remove spare Subcommand

How to Remove a Spare Disk or a RAID Volume

modify Subcommand

How to Modify the BIOS Boot Target

How to Disable Auto Rebuild

How to Modify a RAID Volume Name

start task and stop task Subcommands

Start and Stop Task Examples

restore config and clear config Subcommands

How to Check a Controller Configuration Exists

How to Restore a RAID Controller Configuration

How to Clear a RAID Controller Configuration

export Subcommand

How to Export Inventory Data to a File

import Subcommand

How to Configure RAID Volumes from a File

Creating RAID Volumes With Partial Disks

Guidelines for Using the RAID Volume Size Option

Disk Display

Deletion of RAID Volumes With Partial Disks

Exporting a RAID Configuration Including a RAID Volume With Partial Disks

Adding or Removing a Partial Disk

Using the ilomconfig Tool

ilomconfig Overview

ilomconfig Features

Restoring and Modifying Oracle ILOM XML Configuration Files

Host-to-ILOM Interconnect

OS-Specific Notes

ilomconfig Commands

ilomconfig Command Usage

Options

Subcommands

XML File Configuration Commands

How to Export an XML Configuration

How to Import an XML Configuration

How to Restore Oracle ILOM to Defaults

How to List System Summary Information

How to Create a User

How to Delete a User

How to Modify a User Password or Role

How to List Users

How to List an SNMP Community

How to Create an SNMP Community

How to List IPv4 Network Settings

How to Modify IPv4 Network Settings

How to List IPv6 Network Settings

How to Modify IPv6 Network Settings

How to List Service Processor Identification Information

How to Modify Identification Information

How to List DNS Information

How to Modify DNS Information

How to List Clock Information

How to Modify Clock Information

Host-to-ILOM Interconnect Configuration Commands

How to Enable the Host-to-ILOM Interconnect

How to Disable the Host-to-ILOM Interconnect

How to Modify the Host-to-ILOM Interconnect

How to List the Host-to-ILOM Interconnect Settings

How to Set Up a Credential Cache on the Host

How to Delete a Credential Cache on the Host

Using the hwmgmtcli Tool

hwmgmtcli Command Overview

list Subcommand

How to List Subsystem Information

How to View Open Problems

export Subcommand

How to Export Subsystem Information

Using the zoningcli Tool

zoningcli Command Overview

list expander Subcommand

How to List Zoning Information

enable zoning and disable zoning Subcommands

How to Enable and Disable Zoning

Using ipmitool for Windows

ipmitool Overview

Sun IPMI System Management Driver 2.1

Configuring Boot Order Using ipmitool

CLI Tools Error Codes

Common Error Codes

biosconfig Error Codes

raidconfig Error Codes

ilomconfig Error Codes

fwupdate Error Codes

hwmgmtcli Error Codes

zoningcli Error Codes

Index

list Subcommand

The list command does the following:

This information can be used to check the state of a device before executing a firmware upgrade and can be used to verify that a firmware update has been successful.

The list options are listed in the following table.

Short Option
Long Option
Description
–n
–-device_name
Allows a mandatory parameter to designate a single device to list. The –-device_name option is the common-mapped device name.
–v
–-verbose
Displays detailed information about each component listed. Verbose is off by default.
–x
–-xml=file
Uses the provided XML metadata file to determine which components are supported.
–o
–-output_xml=file
Prints the configuration information in XML format to the given file.

The list command has two types of targets: the first lists the configuration of devices on the system or supported by a file, and the second lists the features supported by fwupdate.

The following supported targets for the list subcommand represent all of the supported component types that can be upgraded by fwupdate:

For example, use the all option to view all of the devices that can be updated using the XML metadata file.

The following supported targets for the list command represent the devices that can be upgraded by fwupdate:

For example, use the supported-targets option to view all of the types of target device that can be updated using fwupdate.

The following information is displayed with the list command for the following targets. Items marked with an asterisk (*) are displayed in verbose listing.

The following are some examples of the output for fwupdate list commands:

fwupdate list disk -v

==================================================
CONTROLLER
==================================================
ID: c0
Node ID: mptir2:40:00.0
Type: SAS
Manufacturer: LSI Logic
Model: 0x0072
Product Name: SGX-SAS6-REM-Z
FW Version: 11.05.02.00
BIOS Version: 07.21.04.00
EFI Version: 07.18.02.13
FCODE Version: 01.00.60.00
PCI Address: 40:00.0
PCI Vendor ID: 0x1000
WWN: 0x500605b005243000
NVDATA Version: 10.03.00.26 (default) 10.03.00.27 (persistent)
XML Support: N/A


DISKS
===============
ID: c0d0
Manufacturer: HITACHI
Model: H106030SDSUN300G
Slot: 2
Node ID: PDS:5000cca02515b089
Type: sas
Media: HDD
Size (GB): 300
FW Version: A2B0
XML Support: N/A

ID: c0d1
Manufacturer: HITACHI
Model: H106030SDSUN300G
Slot: 3
Node ID: PDS:5000cca025143f79
Type: sas
Media: HDD
Size (GB): 300
FW Version: A2B0
XML Support: N/A

fwupdate list sp_bios -x metadata_3.1.2.10.b.xml

SP + BIOS
==================================================
ID        Product Name        ILOM Version         BIOS/OBP Version   XML Support
---------------------------------------------------------------------------------
sp_bios   SUN FIRE X4170 M3   v3.1.2.10.a r75921   17030100           Yes 

fwupdate list controller -n c0 -v

CONTROLLER
=============
ID: c0
Node ID: mptmega:41:00.0
Type: SAS
Manufacturer: LSI Logic
Model: 0x0079
Product Name: LSI MegaRAID SAS 9261-8i
FW Version: 2.130.353-1803
BIOS Version: 3.24.00
EFI Version: 4.12.05.00
FCODE Version:
PCI Address: 41:00.0
PCI Vendor ID: 0x1000
XML Support: N/A

fwupdate list disk -n c2d0

DISK
=============
ID     Manufacturer   Model               Chassis Slot   Type   Media   Size (GB) FW Version XML Support
--------------------------------------------------------------------------------------------------------
c2d0   ATA            3E128-TS2-550B01    -       -      sata   SSD     100       TI35       N/A

fwupdate list disk -n c2d0 -v

DISK
=============
ID: c2d0
Manufacturer: ATA
Model: 3E128-TS2-550B01
Node ID: PDD:/dev/sg3
Type: sata
Media: SSD
Size (GB): 100
FW Version: TI35
XML Support: N/A

fwupdate list expander -n c1x0

EXPANDER
=============
ID     Chassis Slot Manufacturer  Model     Expander Name  FW Version   XML Support
-----------------------------------------------------------------------------------
c1x0   0       -    ORACLE        DE2-24P   Primary        0010         N/A

fwupdate list expander -n c1x0 -v

EXPANDER
=============
ID: c1x0
Chassis: 0
Manufacturer: ORACLE
Model: DE2-24P
Expander Name: Primary
FW Version: 0010
Product Revision: 0010
Node ID: EC:mpt2sas:30:00.0:5080020001431f3e
XML Support: N/A

See also: