JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Storage 2500-M2 Arrays

Hardware Release Notes, Release 6.10

search filter icon
search icon

Document Information

1.  Sun Storage 2500-M2 Arrays Hardware Release Notes

What's New in This Release

Product Overview

About the Management Software

System Requirements

Firmware Requirements

Supported Disk Drives and Tray Capacity

Array Expansion Module Support

Data Host Requirements

Multipathing Software

Supported Host Bus Adaptors (HBAs)

Supported FC and Multilayer Switches

Expansion Tray Specifications

ALUA/TPGS Multipathing with VMware

Procedure for ESX4.1U2 and ESXi5.0

Procedure for ESX4.1U3 and ESXi5.0U1

Restrictions and Known Issues

Restrictions

Single Path Data Connections

SAS Host Ports on the Sun Storage 2540-M2

Controller Issues

Log Events With smartd Monitoring Enabled

After Re-Installing the Oracle Virtual Machine (OVM) Manager, International Standards Organizations (ISO) Files Are Listed by Universally Unique Identifier (UUID) Rather Than by Friendly Name

After Un-Mapping a Volume from an Oracle Virtual Machine (OVM) Server, the Volume Continues to Appear in the Storage Database on the Server

In the Oracle Virtual Machine (OVM) Manager User Interface, Only One Drive at a Time Can Be Selected for Deletion

Kernel Panics During Controller Firmware (CFW) Download

BCM Driver Fails to Load

Kernel Panics During Controller Firmware Download

Network Interface on Device eth0 Fails to Come Online When Booting a Host

When Over 128 Volumes are Mapped to a Host, Paths to Only the First 128 Volumes are Restored after the Controller is Reset

Tasks Aborts Are Logged During a Controller Firmware Upgrade

Unable to Add More Than 117 Volumes to the Oracle Virtual Machine (OVM) Manager Database

Write-Back Cache is Disabled after Controllers Reboot with Multiple Failed Volumes in a Storage Array

During Multiple Node Failover/Failback Events, Input/Output (I/O) Operations Time Out Because a Resource is Not Available to a Cluster

After an NVSRAM Download, a Controller Reboots a Second Time when the NVSRAM is Activated

When a Controller is Not Set Offline Before Being Replaced, an Exception Occurs when the Replacement Controller is Brought Online

Input/Output (I/O) Errors Occur when Disconnection of Devices from a SAS Switch Is Not Detected

A Path Failure and Premature Failover Occur when a Cable is Disconnected between a Host and a Controller

Input/Output (I/O) Errors Occur when a Cable is Disconnected between a Host and a Controller, and the Alternate Controller is Unavailable

With 3 Gb/s SAS Host Bus Adapters (HBAs) and Heavy Input/Output (I/O), I/O Timeouts Occur During a Controller Firmware Upgrade

Host Operating System Logs "Hung Task" During a Path Failure

Backup Failure or I/O Errors with Snapshot Creation or Mounting Failure During Backup of Cluster Shared Volumes (CSV)

With Multiple SAS Hosts Using Single‐PHY, a Host Cable Pull During Input/Output (I/O) Operations Causes a Controller Reboot

Data is Misread when a Physical Drive Has an Unreadable Sector

Solaris 10 Guest in Fault Tolerant Mode Is Unable to Relocate Secondary Virtual Machine (VM) Upon Host Failure

Documentation Bugs

Hardware Installation Guide

Related Documentation

Documentation, Support, and Training

System Requirements

The software and hardware products that have been tested and qualified to work with Sun Storage 2500-M2 arrays are described in the following sections.

Firmware Requirements

The Sun Storage 2500-M2 arrays firmware version 07.84.53.10 is delivered with Sun Storage Common Array Manager (CAM), Version 6.10. The firmware is bundled with the CAM software download package. Download the latest version of CAM as described in the Sun Storage Common Array Manager Release Notes, Version 6.10.

Before you perform an online controller firmware upgrade, read the article “Recommended Settings for the fcp_offline_delay Variable When Upgrading a Sun Storage 6000, 2500, or 2500-M2 Controller Firmware“ (Doc ID 1569976.1) located on MOS. This article describes how to modify fibre channel timeout values for Solaris SPARC and x86 hosts.


Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.


Supported Disk Drives and Tray Capacity

See Hardware Specifications in the Oracle System Handbook for the latest disk drive information:

https://support.oracle.com/handbook_private/Systems/2530_M2/2530_M2.html

https://support.oracle.com/handbook_private/Systems/2540_M2/2540_M2.html

Array Expansion Module Support

The Sun Storage 2530-M2 and 2540-M2 arrays can be expanded by adding Sun Storage 2501-M2 array expansion trays. To add capacity to an array, refer to the following Service Advisor procedures:


Caution

Caution - To add trays with existing stored data, contact My Oracle Support for assistance to avoid data loss.


Table 1-1 IOM Code for Sun Storage 2501-M2 Expansion Tray

Array Controller
Firmware
Supported Expansion Tray
IOM Code
Sun Storage 2500-M2
07.84.53.10
2501-M21
0366

1Only 2501-M2 expansion trays are supported with a 2500-M2 controller tray

Data Host Requirements

Multipathing Software

You must install multipathing software on each data host that communicates with the Sun Storage 2500-M2 arrays.

Table 1-2 Supported Data Host OS and Multipathing Software

Operating System
Multipathing Software
Solaris 11 (initial)
MPxIO
Solaris 11 ALUA/TPGS
MPxIO (TPGS)
Solaris 10u5 (minimum1)
MPxIO
Oracle Linux 6.5, 6.4, 6.3, 6.2, 6.1, 6.0

Oracle Linux 5.9, 5.8, 5.7, 5.6, 5.5

RDAC or DMMP
RDAC
Oracle Unbreakable Linux

Oracle Unbreakable Linux 2

DMMP
Oracle VM 3.1.1
DMMP
Oracle VM 2.2.2
RDAC
RHEL 6.5, 6.4, 6.3, 6.2, 6.1, 6.0

RHEL 5.9, 5.8, 5.8, 5.7, 5.6, 5.5

RDAC or DMMP
RDAC
SLES 10.4, 10.3, 10.2, 10.1, 10.0

SLES 11.3, 11.2, 11.1, 11.0

RDAC or MPP
RDAC or DMMP
VMware ESXi 4.1 update 1 and 5.0
Native Multipathing (NMP)
Windows 2003 SP2 R2 Non-clustered
MPIO
Windows 2003/2008 MSCS Cluster
MPIO
Windows 2008 SP1 R2 (64-bit only)
MPIO

1Oracle recommends installing the latest Solaris update.

Supported Host Bus Adaptors (HBAs)

Table 1-3 Supported Fibre Channel HBAs for Solaris Data Host Platforms

Oracle 2-Gbit HBAs
Oracle 4-Gbit HBAs
Oracle 8-Gbit HBAs
SG-XPCI1FC-QL2 (6767A)
SG-XPCIE1FC-QF4
SG-XPCIE1FC-QF8-Z
SG-XPCI2FC-QF2-Z (6768A)
SG-XPCIE2FC-QF4
SG-XPCIE2FC-QF8-Z
SG-XPCI1FC-EM2
SG-XPCIE1FC-EM4
SG-XPCIE1FC-EM8-Z
SG-XPCI2FC-EM2
SG-XPCIE2FC-EM4
SG-XPCIE2FC-EM8-Z
SG-XPCI1FC-QF4
SG-XPCIEFCGBE-Q8
SG-XPCI2FC-QF4
SG-XPCIEFCGBE-E8
SG-XPCI1FC-EM4
SG-XPCI2FC-EM4
SG-XPCIE2FCGBE-Q-Z
SG-XPCIE2FCGBE-E-Z

Table 1-4 Supported Fibre Channel HBAs for Linux Data Host Platforms

Generic HBAs
Oracle 2-Gbit HBAs
Oracle 4-Gbit HBAs
Oracle 8-Gbit HBAs
QLogic:
SG-XPCI1FC-EM2
SG-XPCIE1FC-QF4
SG-XPCIE1FC-QF8-Z
QLE 256x
SG-XPCI2FC-EM2
SG-XPCIE2FC-QF4
SG-XPCIE2FC-QF8-Z
QLE 246x
SG-XPCI1FC-QL2
SG-XPCIE1FC-EM4
SG-XPCIE1FC-EM8-Z
QLA 246x
SG-XPCI2FC-QF2-Z
SG-XPCIE2FC-EM4
SG-XPCIE2FC-EM8-Z
QLA 234x
SG-XPCI1FC-QF4
SG-XPCIEFCGBE-Q8
QLA 2310F
SG-XPCI2FC-QF4
SG-XPCIEFCGBE-E8
Emulex:
SG-XPCI1FC-EM4-Z
LP982/LP9802/ 9802DC
SG-XPCI2FC-EM4-Z
LP9002/LP9002DC/ LP952
SG-XPCIE2FCGBE-Q-Z
LP10000/10000DC/ LP1050
SG-XPCIE2FCGBE-E-Z
Lpe11000/LPe11002/ LPe1150
Lpe12000/LPe12002/ LPe1250

Table 1-5 Supported Fibre Channel HBAs for Windows Data Host Platforms

Generic HBAs1
Sun 2-Gb HBAs
Sun 4-Gb HBAs
Sun 8-Gb HBAs
QLogic:
SG-XPCI1FC-EM2
SG-XPCIE1FC-QF4
SG-XPCIE1FC-QF8-Z
QLE 256x
SG-XPCI2FC-EM2
SG-XPCIE2FC-QF4
SG-XPCIE2FC-QF8-Z
QLE 246x
SG-XPCI1FC-QL2
SG-XPCIE1FC-EM4
SG-XPCIE1FC-EM8-Z
QLA 246x
SG-XPCI2FC-QF2-Z
SG-XPCIE2FC-EM4
SG-XPCIE2FC-EM8-Z
QLA 234x
SG-XPCI1FC-QF4
SG-XPCIEFCGBE-Q8
QLA 2310F
SG-XPCI2FC-QF4
SG-XPCIEFCGBE-E8
Emulex:
SG-XPCI1FC-EM4
LPe12000/LPe12002/ LPe1250
SG-XPCI2FC-EM4
Lpe11000/LPe11002/LPe1150
SG-XPCIE2FCGBE-Q-Z
LP11000/LP11002/LP1150
SG-XPCIE2FCGBE-E-Z
LP9802/9802DC/982
LP952/LP9002/LP9002DC
10000/10000DC/LP1050

1For generic HBA support, contact the HBA manufacturer.

Table 1-6 Supported SAS HBAs for Solaris and Linux Data Host Platforms

Oracle 3-Gbit HBAs (SAS-1)
Oracle 6-Gbit HBAs (SAS-2)1
SG-XPCIE8SAS-E-Z
SG(X)-SAS6-EXT-Z
SG-XPCIE8SAS-EB-Z
SG(X)-SAS6-EM-Z

1See Restrictions.

Table 1-7 Supported SAS HBAs for Microsoft Windows Data Host Platforms

Oracle 3-Gbit HBAs (SAS-1)
Oracle 6-Gbit HBAs (SAS-2
SG-XPCIE8SAS-E-Z
SG(X)-SAS6-EXT-Z
SG(X)-SAS6-EM-Z

Supported FC and Multilayer Switches

The following FC fabric and multilayer switches are compatible for connecting data hosts and the Sun Storage 2540-M2 array. See the release notes for your switch hardware for firmware support information.