7320 CPU and Memory Components
7320 Power Distribution and Fan Module Components
7320 Single and Cluster Controller Configurations
7420 Standalone and Cluster Controller Configurations
7720 Cluster Controller Configurations
7x20 and 7700 CRU Maintenance Procedures
Required Tools and Information
7x20 Controller Replacement Tasks
7x20 Cabinet Replacement Tasks
Disk Shelf Maintenance Procedures
Electrostatic Discharge Precautions
Use the information in this section as a preparation reference for servicing replaceable components of the 7120 system.
Refer to the following for procedural instructions:
Controller Tasks - replace system controller components
Disk Shelf Tasks - replace disk shelf components
The Sun ZFS Storage 7120 is an enterprise-class two-socket rackmount x64 system powered by the Intel Xeon processor. It packs high performance and room for growth with four PCIe slots and 18 DIMM slots into a compact 2U footprint. Refer to the http://www.sun.com/storage/disk_systems/unified_storage/7120/specs.xml for the most recent component specification.
The 7120 is a standalone controller that consists of a SAS-2 HBA providing disk shelf expansion, optional read and write flash accelerators, and 1TB and 2TB hard drives. The SAS-2 storage fabric supports greater number of targets, greater bandwidth, higher reliability and bigger scale.
The 2U chassis form factor dimensions are as follows:
|
The following figure shows the front panel and the table describes the drive locations.
| |||||||||||||||||||||
The following figure shows the rear panel. Note that optional Sun Dual
Port 40Gb/sec 4x Infiniband QDR HCAdapter PCIe cards (375-3606-01) may be located
in slots 1, 2, or 3. Note that 375-3606-01 HCA expansion cards
are not supported in the 10Gb network configurations. 
| |||||||||||||||||
The serial management connector (SER MGT) is an RJ-45 port and provides
a terminal connection to the SP console. ![]()
The network management connector (NET MGT) is an RJ-45 port and provides
an alternate terminal interface to the SP console. ![]()
There are four RJ-45 Gigabit Ethernet ports (NET0, NET1, NET2, NET3) located on the motherboard that operate at 10/100/1000 Mbit/sec. These network interfaces must be configured before use.
The following list shows the electrical specifications for the 7120. Note that the power dissipation numbers listed are the maximum rated power numbers for the power supply. The numbers are not a rating of the actual power consumption of the appliance.
Connectors
Two C13 connectors which work on 110-220v outlets
Input
Nominal frequencies: 50/60Hz
Nominal voltage range: 100-120/200-240 VAC
Maximum current AC RMS: 13.8A @ 100 VAC
AC operating range: 90-264 VAC
Output
3.3 VDC STBY: 3.0A
+12 VDC: 86.7A
Power dissipation
Max power consumption: 1235.3 W
Max heat output: 4212 BTU/hr
Volt-Ampere rating: 1261 VA @ 240 VAC, 0.98P.F.
The chassis has the following boards installed. Field-replaceable units (FRU) should only be replaced by trained Sun service technicians.
PCIe Risers - Each riser supports two PCIe cards that are customer-replaceable. There are two risers per system, each attached to the rear of the motherboard.
Motherboard - The motherboard is a FRU and includes CPU modules, slots for 18 DIMMs, memory control subsystems, and the service processor (SP) subsystem. The SP subsystem controls the host power and monitors host system events (power and environmental). The SP controller draws power from the host's 3.3V standby supply rail, which is available whenever the system is receiving AC input power, even when the system is turned off.
Power Distribution Board - The power distribution board is a FRU and distributes main 12V power from the power supplies to the rest of the storage controller. It is directly connected to the Connector Break Out Board, and to the motherboard through a bus bar and ribbon cable. It also supports a top cover interlock kill switch. The power supplies connect directly to the power distribution board.
Connector Break Out Board - The Connector Break Out Board is FRU and serves as the interconnect between the power distribution board and the fan power boards, storage drive backplane, and I/O board. It also contains the top-cover interlock "kill" switch.
Fan Power Boards - The two fan power boards are FRUs and carry power to the system fan modules. In addition, they contain fan module status LEDs and transfer I2C data for the fan modules.
Storage Drive Backplane - The storage drive backplane is a FRU and includes the connectors for the storage drives, as well as the interconnect for the I/O board, Power and Locator buttons, and system/component status LEDs. The system has a 12-disk backplane. Each drive has an LED indicator for Power/Activity, Fault, and Locate.
The I/O components of the 7120 system are shown in the following
figure and described in the table. 
| ||||||
The storage controller's internal cables are shown in the following figure and
table. Note that the rear boot drives are not depicted in this
illustration. 
|
|
The 7120 motherboard has 18 slots in two groups that hold industry-standard
DDR3 DIMMs. The 7120 CPU and memory should only be replaced by
field service professionals. All sockets must be occupied by either a
filler or a DDR3 DIMM. All DDR3 DIMMs must be identical. DIMMs
are pre-installed in P0 slots D1, D2, D4, D5, D7, and D8.

The fan modules and LEDs are shown in the following illustration. 
The power distribution and associated components are shown in the following illustration
and described in the table. 
| |||||||||||
The following table shows the configuration options for a 7120 controller. All PCIe cards are low-profile, and must be fitted with low-profile mounting brackets.
This table describes base configurations for the 7120.
|
This table describes NIC/HBA options for the 7120.
|
This table describes the supported PCIe configuration option summary for the 7120.
|