Skip navigation.

LIBTMIB Messages 0-99

  Previous Next

1

INFO: Abortively terminating client process pid

Description

An /AdminAPI request to change the state of a client to DEAD has caused the system to attempt termination of the process pid with the SIGKILL signal.

Action

Informational message only, no action required.

See Also

MIB(5), TM_MIB(5)

2

ERROR: Server group name does not match existing group

Description

The server group name, TA_SRVGRP, specified on a SET request for the T_SERVER class, is not a recognized server group.

Action

Correct the server group name and regenerate the request.

See Also

MIB(5), TM_MIB(5)

3

ERROR: Invalid class name (class) presented to /Admin service svc

Description

The class name class is not recognized by the administrative service svc.

Action

Correct the service name and regenerate the request.

See Also

MIB(5), TM_MIB(5)

4

ERROR: SYSTEM_ACCESS mismatch with NO_OVERRIDE set in T_DOMAIN class

Description

A SET operation on a T_SERVER class object with the TA_SYSTEM_ACCESS attribute being updated specified a value different than that set in the T_DOMAIN class object and the NO_OVERRIDE modifier is also set in the T_DOMAIN class object.

Action

Remove the change to the TA_SYSTEM_ACCESS value from the SET request or remove the NO_OVERRIDE modifier from the T_DOMAIN class object.

See Also

MIB(5), TM_MIB(5)

5

ERROR: TA_MAX(max) not set >= TA_MIN(min)

Description

The maximum number of server instances max specified on a T_SERVER class SET request was less than the specified minimum number of instance min.

Action

Lower min or raise max to be in accordance with the restriction and regenerate the request.

See Also

MIB(5), TM_MIB(5)

6

ERROR: SET operation violates restrictions on servers with same TA_RQADDR

Description

The request queue address name for a T_SERVER class object is being SET to a value matching an existing server that is either a different server name or a different server group.

Action

Either set the request queue address name to something different than the matching servers name or change the server name and/or server group to match the desired existing servers attribute values and regenerate the request.

See Also

MIB(5), TM_MIB(5)

7

ERROR: Overlapping range for TA_SRVGRP, TA_SRVID and TA_MAX

Description

A SET operation on a T_SERVER class object violated the restriction that within a particular server group, servers may not have overlapping server identifiers. This restriction takes into account the base server identifier as well as the setting for the maximum number of server instances.

Action

Lower the maximum number of server instances to eliminate the overlap or shift the base server identifier to avoid the overlap and regenerate the request.

See Also

MIB(5), TM_MIB(5)

8

ERROR: SET of TA_STATE to NEW matches existing class instance

Description

An attempt was made to create a new object via the /AdminAPI, but the object keys specified in the request match an existing class object.

Action

Correct the keys used and regenerate the request.

See Also

MIB(5), TM_MIB(5)

9

ERROR: Global /Admin update failed processing on LMID(lmid) with error code(num) and status(status)

Description

A SET operation that required global updates in a distribute application failed on one of the logical machines lmid with the /AdminAPI error code num and a status of status.

Action

The system will automatically refresh the remote site bulletin board and/or configuration file as necessary after detecting the failure. The status message should be examined for possible causes of the remote failure. This status message will contain a catalog name and message number that can be referenced in this manual for further information.

See Also

MIB(5), TM_MIB(5)

10

WARN: Could not find registry table entry for server svrgrp/svrid

Description

A SET operation for the indicated server (svrgrp/svrid) attempted to update local attributes but could not locate the registry table entry on the servers logical machine.

Action

This message is indicative of other problems that may cause the registry table problem. The userlog on the servers logical machine should be examined for clues as to any problems that may have occurred leading up to this message. If the cause of the problem is still not clear, then contact your BEA TUXEDO system Technical Support.

See Also

MIB(5), TM_MIB(5)

11

ERROR: Cannot update T_SERVICE class with active T_SVCGRP instance

Description

An /AdminAPI request to SET attribute values for a T_SERVICE class object could not be satisfied because a corresponding T_SVCGRP class object (matching TA_SERVICENAME values) is currently ACTIVE.

Action

Defer the update of the T_SERVICE class object until all of the corresponding T_SVCGRP objects are deactivated.

See Also

MIB(5), TM_MIB(5)

12

WARN: AUTOTRAN specified for SERVICE service with TRANTIME=0

Description

An /AdminAPI SET request resulted in an TA_AUTOTRAN attribute value for the service svc of Y and a TA_TRANTIME attribute value for the service svc of 0. This indicates an infinite timeout for transactions started in the server by virtue of the autotran characteristic and may result in "hung" servers if application failures result in transactions that do not complete. This setting should be made only with great care and the understanding of the administrator as to its possible side effects.

Action

Examine the object to be sure that the settings are what is intended and correct them if necessary.

See Also

MIB(5), TM_MIB(5)

13

ERROR: SET operation did not specify unique class instance

Description

The indicated /AdminAPI SET request did not match a unique class object. The key fields provided match more than one object and are ambiguous as to which should be affected.

Action

Provide sufficient key fields to restrict the request to exactly one object and regenerate the request.

See Also

MIB(5), TM_MIB(5)

14

ERROR: Invalid class name (class) presented to /Admin service svc

Description

The class name class is not recognized by the administrative service svc

Action

Correct the service name and regenerate the request.

See Also

MIB(5), TM_MIB(5)

15

WARN: ROUTING criteria (for SERVICE svc) is not defined in the ROUTING section

Description

The TA_ROUTINGNAME value criteria being set for a T_SERVICE class object with service name svc is not currently configured as a T_ROUTING class object.

Action

This situation will cause an error for types which have system support for routing such as FML and VIEWS. However, application types or types for which the application supplies their own customized routing function may function fine. These functions are passed the routing criteria name and process in their own way. The action to be taken depends on whether the application is relying on system support for routing. If they are, then a T_ROUTING object with a matching criteria name should be defined. Otherwise, no action is necessary.

See Also

MIB(5), TM_MIB(5)

16

ERROR: SET keys do not match existing class instance

Description

An /AdminAPI request to SET attributes did not match an existing class instance. All requests other than a state change to NEW must match exactly one existing class object to be processed.

Action

Correct the request to address an existing class object and regenerate.

See Also

MIB(5), TM_MIB(5)

17

ERROR: TA_SVCRNAM may be set only when Activating service

Description

A SET operation on a T_SVCGRP class object attempted to set the value for the TA_SVCRNAM attribute value without including a state change to the ACTIVE state. This is an invalid combination of attribute changes for this class.

Action

Include the setting of TA_SVCRNAM in an activation request for the object in question and remove it from other types of updates to this class.

See Also

MIB(5), TM_MIB(5)

18

WARN: AUTOTRAN specified for SERVICE svc with TRANTIME=0

Description

An /AdminAPI SET request resulted in an TA_AUTOTRAN attribute value for the service svc of Y and a TA_TRANTIME attribute value for the service svc of 0. This indicates an infinite timeout for transactions started in the server by virtue of the autotran characteristic and may result in "hung" servers if application failures result in transactions that do not complete. This setting should be made only with great care and the understanding of the administrator as to its possible side effects.

Action

Examine the object to be sure that the settings are what is intended and correct them if necessary.

See Also

MIB(5), TM_MIB(5)

19

ERROR: TA_AUTHSVC specified without security turned on

Description

A SET operation on the T_DOMAIN class object specified a value for the TA_AUTHSVC attribute without having security turned on via the TA_SECURITY attribute. This is an invalid combination of attribute values.

Action

Either turn on security before or with the request to set the TA_AUTHSVC attribute or remove the value for TA_AUTHSVC from the request.

See Also

MIB(5), TM_MIB(5)

20

ERROR: LAN or MIGRATE option specified without MP TA_MODEL value

Description

A SET operation on the T_DOMAIN class object set either the LAN or MIGRATE option without setting the TA_MODEL attribute value to MP. This is an invalid combination of attribute values.

Action

Either set the TA_MODEL value to MP before or with the request to set the options as specified or eliminate the use of the offending options.

See Also

MIB(5), TM_MIB(5)

21

ERROR: Backup TA_MASTER allowed only for MP TA_MODEL

Description

A backup master logical machine was specified in the TA_MASTER attribute value on a SET request for the T_DOMAIN class object without having the TA_MODEL set to MP. This is an invalid combination of attribute values.

Action

Either set the TA_MODEL value to MP before or with the change to the TA_MASTER attribute value or eliminate the setting of the backup master logical machine.

See Also

MIB(5), TM_MIB(5)

22

ERROR: Invalid master machine specified in TA_MASTER

Description

The master logical machine identifier in the TA_MASTER attribute value for a SET operation on the T_DOMAIN class object is invalid. It either represents a logical machine other than the actual master machine or it represents an unconfigured logical machine identifier.

Action

Correct the logical machine identifiers used in the request.

See Also

MIB(5), TM_MIB(5)

23

ERROR: Invalid backup machine specified in TA_MASTER

Description

The logical machine identifier specified in the TA_MASTER attribute value on a SET operation for the T_DOMAIN class object does not match any configured logical machines.

Action

Correct the logical machine identifier used for the backup machine.

See Also

MIB(5), TM_MIB(5)

24

ERROR: TA_SYSTEM_ACCESS value set with NO_OVERRIDE contradicts T_SERVER settings

Description

An attempt was made to set the NO_OVERRIDE modifier on the TA_SYSTEM_ACCESS attribute value for the T_DOMAIN class object with a primary TA_SYSTEM_ACCESS attribute value that does not match all of the currently configured T_SERVER class objects.

Action

Either remove the NO_OVERRIDE modifier so that the primary attribute value may be set or reset the TA_SYSTEM_ACCESS values for all configured T_SERVER class objects prior to setting the T_DOMAIN TA_SYSTEM_ACCESS value with the NO_OVERRIDE modifier.

See Also

MIB(5), TM_MIB(5)

25

ERROR: AUTOTRAN specified for SERVICE svc SRVGRP group with no TMS

Description

A SET operation on a T_SVCGRP class object attempted to set the TA_AUTOTRAN attribute value to Y for service svc in server group group where the indicated server group does not have a TMS associated with it and can therefore not support transactions.

Action

Change the TA_AUTOTRAN attribute value to N or eliminate the setting of this attribute from the request.

See Also

MIB(5), TM_MIB(5)

26

ERROR: TA_LMID value lmid already exists

Description

An attempt to SET a new T_MACHINE class object was made with a logical machine identifier lmid that matches an existing class object.

Action

Change the logical machine identifier and regenerate the request.

See Also

MIB(5), TM_MIB(5)

27

ERROR: TA_LMID value lmid conflicts with existing T_GROUP class instance

Description

An attempt to SET a new T_MACHINE class object was made with a logical machine identifier lmid that matches an existing T_GROUP class object group name (TA_SRVGRP). This is an invalid combination.

Action

Change the logical machine identifier and regenerate the request or invalidate the server group and reuse the current logical machine identifier.

See Also

MIB(5), TM_MIB(5)

28

ERROR: TA_PMID value pmid already exists

Description

An attempt to SET a new T_MACHINE class object was made with a physical machine identifier pmid that matches an existing class object.

Action

Change the physical machine identifier and regenerate the request.

See Also

MIB(5), TM_MIB(5)

29

ERROR: Cannot create new T_MACHINE class instances in SHM mode

Description

A SET operation creating a NEW T_MACHINE class object was made in a SHM mode application as identified in the T_DOMAIN TA_MODEL attribute value. Only one machine is allowed in SHM mode and the creation of NEW machines is therefore disallowed.

Action

If an additional machine needs to be added to the application, then you must shut down the application, change the model to MP, set the LAN TA_OPTIONS value in the T_DOMAIN class object and only then can you add the additional machine.

See Also

MIB(5), TM_MIB(5)

30

ERROR: Cannot create new T_MACHINE class instances, full machine table

Description

A SET operation to create a NEW T_MACHINE class object could not be satisfied because the machine tables have been filled. These tables are sized based on the T_DOMAIN TA_MAXMACHINES attribute value.

Action

Shut down the application, reconfigure the T_DOMAIN TA_MAXMACHINES attribute value and then the new machine may be added to the application.

See Also

MIB(5), TM_MIB(5)

31

ERROR: Insufficient networking information, TA_NADDR or TA_NLSADDR missing

Description

A SET operation either creating a NEW T_MACHINE class object or adding networking information to an existing object did not supply sufficient networking information. The presence of either the TA_BRIDGE or TA_NADDR attribute on a T_MACHINE class object indicates that the machine is network enabled. A network enabled machine must have non-0 length string values specified for both TA_NADDR and TA_NLSADDR.

Action

Supply either or both of the missing TA_NADDR and TA_NLSADDR values.

See Also

MIB(5), TM_MIB(5)

32

ERROR: Networking information may not be specified without LAN option set

Description

A SET operation creating a NEW T_MACHINE class object or modifying an existing object attempted to add one or more of the networking attributes in an application where the T_DOMAIN TA_OPTIONS value LAN is not set.

Action

Add the LAN option to the T_DOMAIN TA_OPTIONS value before adding the networking information for the machine.

See Also

MIB(5), TM_MIB(5)

33

ERROR: One of both of the LMIDs in TA_LMID do not match configured machines

Description

A SET operation for a T_GROUP class object specified a TA_LMID value where either the primary or secondary logical machine identifier did not match a configured machine.

Action

Check both logical machine identifiers and change the invalid identifier to one for a configured machine.

See Also

MIB(5), TM_MIB(5)

34

ERROR: LMIDs not distinct in TA_LMID for T_GROUP

Description

A SET operation for a T_GROUP class object specified identical logical machines for both the primary and secondary logical machine values in the TA_LMID attribute.

Action

Either change one of the logical machine identifiers to a different machine or set the server group to have only a primary machine.

See Also

MIB(5), TM_MIB(5)

35

ERROR: TA_SRVGRP matches defined logical machine name

Description

A SET operation creating a NEW T_GROUP class object specified a TA_SRVGRP attribute value that conflicts with a configured T_MACHINE TA_LMID value. This is an invalid combination of attribute values.

Action

Change the TA_SRVGRP value for the group being created to a value distinct from configured logical machine identifiers.

See Also

MIB(5), TM_MIB(5)

36

ERROR: TA_SRVGRP or TA_GRPNO not unique

Description

A SET operation creating a NEW T_GROUP class object specified a value for either the TA_SRVGRP or TA_GRPNO attribute that is not unique within the class.

Action

Change the server group name and/or the server group number to eliminate the conflict.

37

ERROR: T_GROUP class instance cannot be added, table full

Description

A SET operation to create a NEW T_GROUP class object could not be satisfied because the group tables have been filled. These tables are sized based on the T_DOMAIN TA_MAXGROUPS attribute value.

Action

Shut down the application, reconfigure the T_DOMAIN TA_MAXGROUPS attribute value and then the new server group may be added to the application.

See Also

MIB(5), TM_MIB(5)

38

WARN: TA_OPENINFO/TA_CLOSEINFO ignored for group(group) with no TMS

Description

A SET operation on a T_GROUP class object specified non-0 length values for either or both of TA_OPENINFO and TA_CLOSEINFO for a server group with no associated TA_TMSNAME value. The values specified for TA_OPENINFO and TA_CLOSEINFO are ignored in this case when configuring the group.

Action

If the server group is intended to be associated with a resource manager, then the groups attributes should be modified to include the appropriate TA_TMSNAME value and the values for TA_OPENINFO and TA_CLOSEINFO may be configured at that time.

See Also

MIB(5), TM_MIB(5)

39

ERROR: Machine associated with server group does not have a TLOG device

Description

A SET operation for a T_GROUP class object specified either a primary or secondary logical machine for the group without an associated TA_TLOGDEVICE even though the group is being configured with a non-NULL TA_TMSNAME value. A non-NULL value is one which is non-0 length and is not "TMS".

Action

Either associate TA_TLOGDEVICE values with the selected machines or change the group so that TA_TMSNAME is a non-NULL.

See Also

MIB(5), TM_MIB(5)

40

ERROR: Multiple LMIDs disallowed, MIGRATE option not set

Description

A SET operation on a T_GROUP class object specified both primary and secondary logical machine identifiers and the T_DOMAIN MIGRATE TA_OPTIONS value is not set. This is an invalid combination of attribute values.

Action

Add the MIGRATE option to the T_DOMAIN TA_OPTIONS attribute value and reconfigure the group with the primary and secondary logical machine identifiers.

41

ERROR: TA_GSTATE without TA_GRPNO on T_TRANSACTION group state change

Description

A SET operation on a T_TRANSACTION class object specified a TA_GSTATE attribute value change without a corresponding TA_GRPNO value.

Action

Correct the request to include the appropriate TA_GRPNO value.

See Also

MIB(5), TM_MIB(5)

42

ERROR: TA_GSTATE and TA_STATE specified on T_TRANSACTION group state change

Description

A SET operation on a T_TRANSACTION class object specified changes to both the TA_STATE and TA_GSTATE attribute values. Only one of these attribute values may be changed on any one request.

Action

Remove one of the attribute updates from the request buffer and regenerate.

See Also

MIB(5), TM_MIB(5)

43

ERROR: Permissions violation on SET request

Description

A SET request contained an update to an attribute value that is not allowed for the initiating user in the current object state. The particular attribute violating the permissions is indicated in the field TA_BADFLD.

Action

Remove the update to the offending attribute from the request.

44

ERROR: Invalid GTRID for T_TRANSACTION state change

Description

A SET operation on a T_TRANSACTION class object specified a TA_GTRID value that does not match any outstanding transactions.

Action

Check to be sure that the correct TA_GTRID value was used and correct if necessary. This situation may occur if the transaction is resolved before the request for the state change is generated in which case no action is necessary.

See Also

MIB(5), TM_MIB(5)

45

ERROR: TA_GRPNO not found for T_TRANSACTION class instance

Description

A SET operation on a T_TRANSACTION class object specifying a TA_GSTATE change has specified a corresponding TA_GRPNO value that is not currently part of the indicated transaction.

Action

Correct the TA_GRPNO value and regenerate the request.

See Also

MIB(5), TM_MIB(5)

46

ERROR: Cannot destroy device entry specified

Description

A SET operation to invalidate a T_DEVICE class object could not be processed because of an internal failure to delete the device.

Action

Contact your BEA TUXEDO system Technical Support.

See Also

MIB(5), TM_MIB(5)

47

ERROR: TA_TLOGCOUNT required to write new log records

Description

A SET operation to add transaction log records failed to specify a value for TA_TLOGCOUNT. This attribute is used to determine how many records from the corresponding request should be added to the log.

Action

Add the appropriate value for TA_TLOGCOUNT to the request.

See Also

MIB(5), TM_MIB(5)

48

ERROR: TA_CFGDEVICE required on T_DEVICE GET operation

Description

A GET operation on the T_DEVICE class failed to provide a value for the attribute key field TA_CFGDEVICE as required.

Action

Provide a value for TA_CFGDEVICE that points to a configured BEA TUXEDO system device file name.

See Also

MIB(5), TM_MIB(5)

49

ERROR: Invalid input to T_DEVICE SET request

Description

A SET operation on a T_DEVICE class object did not specify the required change in TA_STATE value to either NEW or INV.

Action

Correct the request to include the appropriate state change.

See Also

MIB(5), TM_MIB(5)

50

ERROR: Could not create device entry specified

Description

A SET operation to create a T_DEVICE class object could not be processed because of an internal failure. Possible causes are

  1. a non-zero offset (TA_DEVOFFSET) was specified for the first device list entry (TA_DEVICE) in the BEA TUXEDO system device file (TA_CFGDEVICE);

  2. control information in the BEA TUXEDO system device file is corrupted;

  3. the specified offset and size overlap with the storage already allocated to another device list entry (TA_DEVICE);

  4. the maximum number of devices allowed in a BEA TUXEDO system device file (TA_CFGDEVICE) was exceeded;

  5. the BEA TUXEDO system device file could not be locked;

  6. an operating system error occurred.

Action

Correct the request.

See Also

MIB(5), TM_MIB(5)

51

ERROR: Cannot destroy device entry 0 while other entries are in UDL

Description

A SET operation to delete a T_DEVICE class object attempted to delete device index 0 without it being the last configured device for this BEA TUXEDO system file system.

Action

Delete the non-0 index devices from the file system before deleting device index 0.

52

ERROR: Invalid TA_OPTIONS modification in active system

Description

A SET operation on the T_DOMAIN class object in an active application changed the existing settings for the TA_OPTIONS value with respect to the LAN and/or MIGRATE options. These options may only be changed in an inactive system.

Action

Shut down the application before attempting to change these options values.

See Also

MIB(5), TM_MIB(5)

53

ERROR: ACCSTATS may not be set in MP model application

Description

A SET operation on the T_DOMAIN class object attempted to set the TA_OPTIONS attribute value ACCSTATS. This attribute value may only be set in SHM mode application.

Action

Convert the application to SHM mode before setting this option value.

See Also

MIB(5), TM_MIB(5)

54

ERROR: Missing or invalid LMID for SET operation

Description

A SET operation modifying information local to only one site did not have the necessary information to route the request to the appropriate logical machine for processing.

Action

Add the correct TA_LMID attribute or other site identifying attribute to the originating request so that the request can be routed correctly.

See Also

MIB(5), TM_MIB(5)

55

ERROR: TA_MASTER migration combined with other T_DOMAIN changes

Description

A SET operation on the T_DOMAIN class specified both a master machine migration and other attribute changes. These activities may not be combined in a single request.

Action

Split the request into a master machine migration and the other changes being requested and make 2 requests instead of the one original request.

See Also

MIB(5), TM_MIB(5)

56

ERROR: Could not perform TA_MASTER migration

Description

A SET operation requested master machine migration. This operation could not be satisfied due to an internal system error.

Action

ACTION Contact your BEA TUXEDO system Technical Support.

See Also

MIB(5), TM_MIB(5)

57

ERROR: Backup machine minor release (b_minor) differs from current master (m_minor)

Description

A SET operation on the T_DOMAIN class object resetting the backup logical machine identifier in the TA_MASTER attribute specified a logical machine with a minor release number b_minor that is different from the master machine minor release number m_minor. The backup and master logical machines must be the same major and minor BEA TUXEDO system release numbers.

Action

Either upgrade the new backup logical machine to the same minor release or select a different logical machine as your backup machine.

See Also

MIB(5), TM_MIB(5)

58

ERROR: T_SVCGRP state change INA to ACT without corresponding active server

Description

A SET operation on a T_SVCGRP class object to set the state from INACTIVE to ACTIVE did not specify sufficient additional key fields to map the request to a active server or queue within the application.

Action

Provide either the TA_RQADDR or the TA_SRVGRP and TA_SRVID attribute values to map the request to an active server for processing.

See Also

MIB(5), TM_MIB(5)

59

ERROR: Alternate LMID not specified for group

Description

A SET operation changing the state of a T_GROUP class object from ACTIVE to MIGRATING was applied to a server group without a configured backup logical machine configured.

Action

Configure a backup logical machine for the server group before requesting migration.

See Also

MIB(5), TM_MIB(5)

60

ERROR: Group does not have an alternate location defined

Description

A SET operation changing the state of a T_GROUP class object from MIGRATING to ACTIVE or REACTIVATE was applied to a server group without a configured backup logical machine configured.

Action

Configure a backup logical machine for the server group before requesting activation.

See Also

MIB(5), TM_MIB(5)

61

ERROR: Alternate location for group (lmid) is not active

Description

A SET operation on a T_GROUP class object requesting a state change from MIGRATING to ACTIVE or REACTIVATE could not be satisfied because the secondary logical machine identifier lmid is not currently active.

Action

Activate the secondary logical machine and then retry the server group state change.

See Also

MIB(5), TM_MIB(5)

62

ERROR: Server group group cannot migrate, server id svrid in an improper state

Description

A SET operation changing the state of a T_GROUP class object from MIGRATING to ACTIVE or REACTIVATE could not be satisfied because the server indicated by group and svrid is not in the MIGRATING state.

Action

Either the migration can be canceled (state change from MIGRATING to INACTIVE) or the offending server can be deactivated prior to retrying the migration.

See Also

MIB(5), TM_MIB(5)

63

ERROR: Could not update group location information

Description

A SET operation on a T_GROUP class object requesting a state change from MIGRATING to ACTIVE or REACTIVATE could not be completed because of an internal system error updating the current group location in the bulletin board.

Action

Consult the userlog on the master site for any indication of the cause of the problem and contact your BEA TUXEDO system Technical Support.

See Also

MIB(5), TM_MIB(5)

64

WARN: Server could not be migrated and was removed from BB

Description

TA_STATUS message indicating that the associated server could not be migrated as requested and has been deactivated.

Action

Consult the userlog on the server groups new site for information on why the server failed to migrate. If the problem can be resolved, the server can be brought back up by activating it normally.

See Also

MIB(5), TM_MIB(5)

65

WARN: Terminating process pid via SIGTERM

Description

An /AdminAPI request to change the state of a T_SERVER class object from ACTIVE or SUSPENDED to DEAD has caused the system to send a SIGTERM signal to the process in an attempt to allow the server to gracefully exit. If the server fails to shut down gracefully within the timeout period for the /AdminAPI request (TA_MIBTIMEOUT), then the server will be abortively terminated with a SIGKILL signal.

Action

Informational message only, no action required.

See Also

Usignal(3c), MIB(5), TM_MIB(5)

66

WARN: Terminating process pid via SIGKILL

Description

An /AdminAPI request to change the state of a T_SERVER class object from ACTIVE or SUSPENDED to DEAD has caused the system to send a SIGKILL signal to the process to abortively terminate the server.

Action

Informational message only, no action required

See Also

Usignal(3c), MIB(5), TM_MIB(5)

67

ERROR: Cannot change primary LMID for an active T_GROUP class instance

Description

A SET operation for a T_GROUP class object attempted to change the primary logical machine identifier for an active server group.

Action

Server group migration is achieved by setting the TA_STATE of the group to MIGRATING followed by completing any group specific migration activities and finally by setting the TA_STATE of the group to ACTIVE. Once this sequence is completed, the primary and backup logical machines for the group will be reversed.

See Also

MIB(5), TM_MIB(5)

68

ERROR: Cannot delete a T_MACHINE class instance with a pre-5.0 release site active

Description

A operation to delete a T_MACHINE class instance could not be satisfied because one or more machines in the configuration is running a release prior to 5.0.

Action

BEA TUXEDO system sites running releases prior to 5.0 do not have the /AdminAPI service and the requested global update cannot be done while those systems are active within the application. Otherwise, the indicated machines userlog file should be examined for possible causes of the missing service. The indicated machine can be deactivated and reactivated in an attempt to make the required service available.

See Also

MIB(5), TM_MIB(5)

69

ERROR: Cannot invalidate T_MACHINE class instance specified in T_DOMAIN TA_MASTER attribute

Description

A SET operation on a T_MACHINE class object to set the TA_STATE from INACTIVE to INVALID could not be satisfied because the logical machine identifier is referenced in the T_DOMAIN TA_MASTER attribute value.

Action

Change the T_DOMAIN TA_MASTER value to reference other machines before attempting to invalidate this machine.

See Also

MIB(5), TM_MIB(5)

70

ERROR: Cannot invalidate T_MACHINE class instance specified in T_GROUP TA_LMID attribute

Description

A SET operation on a T_MACHINE class object to set the TA_STATE from INACTIVE to INVALID could not be satisfied because the logical machine identifier is referenced in a T_GROUP TA_LMID attribute value

Action

Change the T_GROUP TA_LMID values to reference other machines before attempting to invalidate this machine.

See Also

MIB(5), TM_MIB(5)

71

ERROR: Cannot invalidate T_GROUPS class instance with servers configured in group

Description

A SET operation on a T_GROUP class object to set the TA_STATE from INACTIVE to INVALID could not be satisfied because their are currently configured T_SERVER class objects associated with the server group.

Action

Invalidate the individual T_SERVER class objects in the group before attempting to invalidate the server group itself.

See Also

MIB(5), TM_MIB(5)

72

ERROR: Cannot invalidate T_GROUPS class instance with services configured in group

Description

A SET operation on a T_GROUP class object to set the TA_STATE from INACTIVE to INVALID could not be satisfied because their are currently configured T_SVCGRP class objects associated with the server group.

Action

Invalidate the individual T_SVCGRP class objects associated with the group before attempting to invalidate the server group itself.

See Also

MIB(5), TM_MIB(5)

73

ERROR: Cannot invalidate T_SERVICE class instance with a corresponding configured T_SVCGRP class instance

Description

A SET operation on a T_SERVICE class object to set the TA_STATE from INACTIVE to INVALID could not be satisfied because their are currently configured T_SVCGRP class objects associated with the same TA_SERVICENAME attribute value.

Action

Invalidate all T_SVCGRP class objects for a particular TA_SERVICENAME value before attempting to invalidate the T_SERVICE class object for that TA_SERVICENAME.

See Also

MIB(5), TM_MIB(5)

74

ERROR: Failed to advertise dynamic /Admin service svc

Description

The administrative service svc could not be offered by the administrative server generating the userlog message during server initialization. This message is generated by one of the following administrative servers: DBBL, BBL or BRIDGE. In the case of a BRIDGE server, the error is non-fatal and the server will boot and continue to function. For the other servers, the error causes server initialization to fail and the server fails to boot.

Action

In most cases, this problem is encountered when the configured size of the services table in the bulletin board is too small. In this case, shut down the application and increase the value for the T_DOMAIN TA_MAXSERVICES attribute before attempting to reboot the application. If this does not solve the problem, then consult the userlog messages immediately preceding and following this message for more information on the failure.

See Also

MIB(5), TM_MIB(5)

75

ERROR: /Admin service input buffer not FML32

Description

An /AdminAPI request was received that was not an FML32 typed buffer. /AdminAPI services process only FML32 typed buffers.

Action

Change the administrative program to generate FML32 requests only.

See Also

Fintro(3fml), MIB(5), TM_MIB(5)

76

ERROR: /Admin service input buffer does not include class

Description

An administrative request received by an /AdminAPI service did not contain a TA_CLASS value. A TA_CLASS value is required as defined in MIB(5).

Action

Correct the request message to include a TA_CLASS value.

See Also

Fintro(3fml), MIB(5), TM_MIB(5)

78

ERROR: Invalid class specified

Description

The TA_CLASS value for an /AdminAPI request is either invalid (does not match any classes known by the system) or is missing.

Action

Examine the original input buffer (also contained with the reply buffer) to see if the TA_CLASS value is missing or invalid. If it is missing, then add the appropriate class value to the buffer. If it is invalid, then check reference pages and spelling and correct the class name in the request.

See Also

MIB(5), TM_MIB(5)

79

ERROR: Invalid operation specified

Description

Missing or invalid value for TA_OPERATION included in /AdminAPI request buffer. This is a required input parameter on all /AdminAPI requests and must have a value of GET, SET or GETNEXT.

Action

Correct the input buffer to include an appropriate value for the TA_OPERATION attribute.

See Also

MIB(5), TM_MIB(5)

80

ERROR: Missing cursor on GETNEXT operation

Description

A TA_CURSOR was not included in a GETNEXT request. GETNEXT operations require a TA_CURSOR value be included with the request. TA_CURSOR values are returned from both GET and GETNEXT operations when there are additional objects matching the request criteria that have not yet been returned.

Action

The required TA_CURSOR value should be extracted from a previous GET or GETNEXT reply message and included in the GETNEXT request.

See Also

MIB(5), TM_MIB(5)

81

ERROR: Invalid cursor (cursor) specified on GETNEXT operation

Description

The TA_CURSOR value provided with a GETNEXT request is invalid. Cursor values have a specific internally defined format and the provided cursor does not match that format.

Action

Insure that cursor values are extracted from previous GET or GETNEXT reply messages and that they are not modified in any way before using them on subsequent GETNEXT requests.

See Also

MIB(5), TM_MIB(5)

82

ERROR: SET operation on readonly class class

Description

A SET request on the class class failed because the indicated class has no writable attributes.

Action

Consult the appropriate reference page for the class in question to see if any attributes are defined as writable in any instance. If not, then the administrative tool being used should be changed to keep from generating SET requests for this class. Otherwise, the permissions for attributes in the class have been changed dynamically (see T_CLASSATT class definition in MIB(5)) to make it a read only class. In this case, the application administrator should be consulted to see if the appropriate action is to change the class permissions or to change the administrative tool to eliminate the request.

See Also

MIB(5), TM_MIB(5)

83

ERROR: Conflicting key values in SET request

Description

A SET request on a class with local information only contained conflicting key values with respect to mapping the request to a particular logical machine. The key values in question may be any of the following depending on the class in question; TA_LMID, TA_PMID, TA_SRVGRP, TA_CLIENTID, TA_SOURCE or TA_GTRID.

Action

Correct the key values on the request to be consistent.

See Also

MIB(5), TM_MIB(5)

84

ERROR: Invalid operation specified

Description

Missing or invalid value for TA_OPERATION included in /AdminAPI request buffer. This is a required input parameter on all /AdminAPI requests and must have a value of GET, SET or GETNEXT.

Action

Correct the input buffer to include an appropriate value for the TA_OPERATION attribute.

See Also

MIB(5), TM_MIB(5)

85

ERROR: Internal System/T failure (tperrno)

Description

Internal BEA TUXEDO system error tperrno encountered while attempting to process master migration.

Action

Contact your BEA TUXEDO system Technical Support.

See Also

MIB(5), TM_MIB(5)

86

ERROR: Invalid TA_MASTER (string) specified on SET operation

Description

An invalid string value for the TA_MASTER attribute was specified on a SET request for the T_DOMAIN class object.

Action

Correct the TA_MASTER value in the request

See Also

MIB(5), TM_MIB(5)

87

ERROR: Invalid TA_MASTER (new_mast,new_back) specified on SET operation

Description

The TA_MASTER value provided on a SET request for the T_DOMAIN class was invalid. The problem is caused either by the new master logical machine new_mast not matching the previous backup logical machine value or by the new backup logical machine new_back not matching the previous master logical machine value.

Action

Correct the request to contain a valid change to the TA_MASTER attribute value as defined in the TM_MIB(5) reference page.

See Also

MIB(5), TM_MIB(5)

88

ERROR: Invalid logical machine identifier (lmid) specified for master

Description

The backup logical machine identifier lmid specified for the TA_MASTER attribute on a SET request for the T_DOMAIN class does not match a configured logical machine.

Action

Correct the request to include a valid logical machine on the request.

See Also

MIB(5), TM_MIB(5)

89

ERROR: Missing /Admin API key field(s) on SET

Description

An /AdminAPI SET request on a class with local attributes only did not specify sufficient key fields to route the request to the logical machine where the object is resident.

Action

Consult the reference page to determine what key fields are available for the class in question and provide sufficient key fields for logical machine mapping.

See Also

MIB(5), TM_MIB(5)

90

ERROR: Class class is not readable to this user

Description

A GET request for class could not be satisfied because the class contains no readable attributes for the invoking user.

Action

In cases where the information is not intended to be available to the invoking user, this message is informational only and there is no action to be taken. If the administrator intended the user to have access to the indicated class, then the permissions on the class need to be relaxed by setting appropriate permissions values via the T_CLASSATT class or by resetting the T_DOMAIN TA_MIBMASK attribute value.

See Also

MIB(5), TM_MIB(5)

91

ERROR: Missing required key field keyfield on T_DEVICE GET request

Description

The key field keyfield is missing on a GET request for the T_DEVICE class. The key field keyfield is required for GET access to the T_DEVICE class as defined in the TM_MIB(5) reference page.

Action

Add the necessary key field value to the request.

See Also

MIB(5), TM_MIB(5)

92

ERROR: Invalid service name (svc) presented to /Admin service

Description

An invalid service name svc has been presented to the /AdminAPI service processing routine.

Action

Correct the requested service on the request.

See Also

MIB(5), TM_MIB(5)

93

ERROR: Invalid service name (svc) presented to /Admin service

Description

An invalid service name svc has been presented to the /AdminAPI service processing routine.

Action

Correct the requested service on the request.

See Also

MIB(5), TM_MIB(5)

94

ERROR: Failed to update FML and VIEW environment variables

Description

/AdminAPI service initialization for the administrative process logging the message failed because the indicated environment variables could not be dynamically updated to include references to directories and files necessary for /AdminAPI processing. This error is caused by a failure to allocate sufficient memory from the system.

Action

Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.

See Also

malloc(3) in UNIX reference manuals, MIB(5), TM_MIB(5)

95

ERROR: Memory allocation failure

Description

An attempt dynamically to allocate memory from the operating system using malloc failed while adding FML and VIEW environment variables to the process memory.

Action

Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.

See Also

malloc(3) in UNIX reference manuals, MIB(5), TM_MIB(5)

97

ERROR: Invalid logical machine specification and/or conflict in search criteria

Description

A GET request contained conflicting key values with respect to mapping the request to a particular logical machine. The key values in question may be any of the following depending on the class in question; TA_LMID, TA_PMID, TA_SRVGRP, TA_CLIENTID, TA_SOURCE or TA_GTRID.

Action

Correct the key values on the request to be consistent.

See Also

MIB(5), TM_MIB(5)

98

WARN: Stray reply during fanout processing, ignored

Description

A GET or SET that required the DBBL to fanout the processing received a stray reply from a previous such request. The stray reply is ignored and processing continues.

Action

This condition may be caused by a number of different conditions. A temporary disruption of network service may cause replies to be delayed past the timeout period. Timeout periods that are too small may cause fanout processing to abandon polling for replies before a reasonable amount of time has passed. Excessive administrative traffic may be clogging the network causing undue delays. If the condition occurs infrequently and is not attributable to a particular request, then no action is indicated. If the condition occurs consistently after a particular request, then examine requests made just previously to see if their timeout values are too small. If the condition occurs frequently, then the T_DOMAIN timer attribute values (TA_SCANUNIT, TA_BBLQUERY, TA_BLOCKTIME, TA_DBBLWAIT and TA_SANITYSCAN) may need to be raised to reduce administrative traffic on the network. Additionally, the administrative tools being used to monitor the system may need to be examined to identify excessive traffic they may be injecting into the system.

See Also

MIB(5), TM_MIB(5)

99

ERROR: Invalid operation (op) specified for /Admin request

Description

Missing or invalid value for TA_OPERATION included in /AdminAPI request buffer. This is a required input parameter on all /AdminAPI requests and must have a value of GET, SET or GETNEXT.

Action

Correct the input buffer to include an appropriate value for the TA_OPERATION attribute.

See Also

MIB(5), TM_MIB(5)

 

Skip footer navigation  Back to Top Previous Next