JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Datacenter InfiniBand Switch 36 HTML Document Collection for Firmware Version 2.0
search filter icon
search icon

Document Information

Using This Documentation

Product Notes

Related Documentation

Feedback

Support and Accessibility

Installation

Understanding the Switch

Switch Overview

Physical Specifications

Environmental Requirements

Acoustic Noise Emissions

Electrical Specifications

Network Management Connector and Pins

USB Management Connector and Pins

Data QSFP Connector and Pins

Understanding Cabling

Routing Service Cables

Understanding Data Cabling

Preparing to Install the Switch

Installation Preparation

Suggested Tools for Installation

Antistatic Precautions for Installation

Installation Responsibilities

Installation Sequence

Verify Shipping Carton Contents

Route the Data Cables

Installing the Switch

Install the Switch in the Rack

Powering On the Switch

Connecting Data cables

Verifying the InfiniBand Fabric

Administration

Troubleshooting the Switch

Switch Hardware Problems

InfiniBand Fabric Problems

Identifying LEDs

Understanding Routing Through the Switch

Switch GUIDs Overview

Understanding Administrative Commands

Configuration Overview

Hardware Command Overview

InfiniBand Command Overview

ILOM Command Overview

Administering the Chassis

Monitoring the Chassis

Controlling the Chassis

Administering the I4 Switch Chip

Monitoring the I4 Switch Chip

Controlling the I4 Switch Chip

Administering the Subnet Manager

Monitoring the Subnet Manager

Controlling the Subnet Manager

Administering the InfiniBand Fabric

Monitoring the InfiniBand Fabric

Controlling the InfiniBand Fabric

Configuring the Fabric Director Node List

Partitioning the InfiniBand Fabric

Remote Management

Understanding Oracle ILOM on the Switch

Oracle ILOM Overview

Supported Features

Understanding Oracle ILOM Targets

Oracle ILOM Target Overview

Oracle ILOM Targets and Descriptions

Oracle ILOM General System Targets and Properties

Oracle ILOM Fan Targets and Properties

Oracle ILOM Indicator Targets and Properties

Oracle ILOM Power Supply Targets and Properties

Oracle ILOM Temperature Targets and Properties

Oracle ILOM Voltage Targets and Properties

Oracle ILOM General Targets and Properties

Oracle ILOM Service Targets and Properties

Oracle ILOM User and Session Targets and Properties

Installing the Oracle ILOM Firmware

Firmware Delivery

Acquire the Oracle ILOM Firmware Version 1.1.3

Install the Oracle ILOM Firmware Version 1.1.3

Administering Oracle ILOM (CLI)

CLI Overview

Accessing Oracle ILOM From the CLI

Switching Between the Oracle ILOM Shell and the Linux Shell

Monitoring Oracle ILOM Targets (CLI)

Controlling Oracle ILOM Targets (CLI)

Upgrading the Switch Firmware Through Oracle ILOM (CLI)

Administering Oracle ILOM (Web)

Web Interface Overview

Access Oracle ILOM From the Web Interface

Monitoring Oracle ILOM Targets (Web)

Controlling Oracle ILOM Targets (Web)

Upgrade the Switch Firmware (Web)

Using the Fabric Monitor

Access the Fabric Monitor

Fabric Monitor Features

Accessing the Rear Panel Diagram

Accessing Status Pane Information

Control Panel Function

Monitoring Parameters and Status

Administering Oracle ILOM (SNMP)

SNMP Overview

Understanding SNMP Commands

Monitoring Oracle ILOM Targets (SNMP)

Controlling Oracle ILOM Targets (SNMP)

Administering Hardware (IPMI)

ipmitool Overview

Display the Sensor States (IPMI)

Display the Sensor Information (IPMI)

Display the System Event Log (IPMI)

Display FRU ID Information (IPMI)

Display Switch Status LED States (IPMI)

Enable the Locator LED (IPMI)

Disable the Locator LED (IPMI)

Understanding Oracle ILOM Commands

cd Command

create Command

delete Command

dump Command

exit Command (ILOM)

help Command (ILOM)

load Command

reset Command

set Command

show Command

version Command (ILOM)

Service

Understanding Service Procedures

Replaceable Components

Suggested Tools for Service

Antistatic Precautions for Service

Servicing Power Supplies

Inspecting a Power Supply

Power Off a Power Supply

Remove a Power Supply

Install a Power Supply

Power On a Power Supply

Servicing Fans

Inspecting a Fan

Remove a Fan

Install a Fan

Servicing Data Cables

Inspecting the Data Cables

Remove a Data Cable

Install a Data Cable

Servicing the Battery

Remove the Switch From the Rack

Replace the Battery

Reference

Understanding Hardware Commands

Linux Shells for Hardware Commands

checkboot Command

checkpower Command

checktopomax Command

checkvoltages Command

connector Command

dcsport Command

disablecablelog Command

disablelinklog Command

disablesm Command

disableswitchport Command

enablecablelog Command

enablelinklog Command

enablesm Command

enableswitchport Command

env_test Command

exit Command (Hardware)

fdconfig Command

fwverify Command

generatetopology Command

getfanspeed Command

getmaster Command

getportstatus Command

help Command (Hardware)

listlinkup Command

matchtopology Command

setcontrolledhandover Command

setmsmlocationmonitor Command

setsmmkey Command

setsmpriority Command

setsubnetprefix Command

showfruinfo Command

showpsufru Command

showsmlog Command

showtemps Command

showtopology Command

showunhealthy Command

smconfigtest Command

smnodes Command

smpartition Command

version Command (Hardware)

Understanding InfiniBand Commands

Linux Shells for InfiniBand Commands

ibdiagnet Command

ibhosts Command

ibnetdiscover Command

ibnetstatus Command

ibnodes Command

ibportstate Command

ibroute Command

ibrouters Command

ibstat Command

ibswitches Command

ibtracert Command

perfquery Command

saquery Command

smpquery Command

Understanding SNMP MIB OIDs

OID Tables Overview

Understanding the SUN-DCS-IB-MIB MIB OIDs

Understanding the SUN-FABRIC-MIB MIB OIDs

Understanding the SUN-HW-TRAP-MIB MIB OIDs

Understanding the SUN-ILOM-CONTROL-MIB MIB OIDs

Understanding the SUN-PLATFORM-MIB MIB OIDs

Understanding the ENTITY-MIB MIB OIDs

Index

Oracle ILOM Targets and Descriptions

This table lists the Oracle ILOM targets supported in the switch and provides a short description of the target.

Oracle ILOM Target
Description
/
Hierarchy root
/SYS
Sensors and FRU information
/SYS/CABLE_ATTN
Aggregate sensor – Overall connector hardware state
/SYS/CABLE_CONN_STAT
Aggregate sensor – Change in cable connectivity state
/SYS/CHASSIS_STATUS
Aggregate sensor – Overall chassis state
/SYS/COOLING_ATTN
Aggregate sensor – Overall cooling state
/SYS/COOLING_REDUN
Aggregate sensor – Cooling redundancy state
/SYS/Fabric_Mgmt
Fabric management Linux shell (ilom-admin user)
/SYS/FANx
Fan x information
/SYS/FANx/PRSNT
Presence of fan x
/SYS/FANx/TACH
Speed of fan x
/SYS/I_ATTENTION
State of Attention LED
/SYS/I_LOCATOR
State of Locator LED
/SYS/I_POWER
State of Power LED
/SYS/IBDEV_ATTN
Aggregate sensor – Overall I4 switch chip state
/SYS/MB
Motherboard information
/SYS/MB/BOOT_I4A
Status of I4 switch chip boot
/SYS/MB/T_BACK
Temperature at rear of chassis
/SYS/MB/T_FRONT
Temperature at front of chassis
/SYS/MB/T_I4A
Temperature of the I4 switch chip
/SYS/MB/T_SP
Temperature of the management controller
/SYS/MB/V_1.8V
Voltage of the main 1.8V source
/SYS/MB/V_1.8VOK
State of the main 1.8V source
/SYS/MB/V_2.5V
Voltage of the main 2.5V source
/SYS/MB/V_2.5VOK
State of the main 2.5V source
/SYS/MB/V_3.3VMain
Voltage of the main 3.3V source
/SYS/MB/V_3.3VMainOK
State of the main 3.3V source
/SYS/MB/V_3.3VStby
Voltage of the standby 3.3V source
/SYS/MB/V_5V
Voltage of the main 5V source
/SYS/MB/V_5VOK
State of the main 5V source
/SYS/MB/V_12V
Voltage of the main 12V source
/SYS/MB/V_BAT
Voltage of the battery
/SYS/MB/V_ECB
State of the Electronic Circuit Breaker
/SYS/MB/V_I41.2V
Voltage of the I4 switch chip
/SYS/MB/V_I41.2VOK
State of the I4 switch chip 1.2V source
/SYS/Platform_CLI
Comprehensive Linux shell
/SYS/POWER_ATTN
Aggregate sensor – Overall power state
/SYS/POWER_REDUN
Aggregate sensor – Power redundancy state
/SYS/PSUx
Power supply x information
/SYS/PSUx/PRSNT
Presence of power supply x
/SYS/PSUx/ALERT
State of power supply x
/SYS/PSUx/AC_PRESENT
Presence of AC input power for power supply x
/SYS/TEMP_ATTN
Aggregate sensor – Overall temperature state
/SYS/Switch_Diag
Diagnostic Linux shell (ilom-operator and ilom-admin users)
/SP
Management controller or Host
/SP/alertmgmt
Alert rule management
/SP/alertmgmt/rules
Alert rules
/SP/cli
CLI
/SP/clients
Clients that connect to external services
/SP/clients/dns
DNS client configuration
/SP/clients/ntp
NTP configuration
/SP/clients/ntp/server
NTP server configuration
/SP/clients/smtp
SMTP email client configuration
/SP/clients/syslog
syslogd management
/SP/clients/syslog/1
syslogd remote logging management 1
/SP/clients/syslog/2
syslogd remote logging management 2
/SP/clock
Clock management
/SP/config
Configuration back up and restore settings
/SP/diag/snapshot
State of switch snapshot
/SP/logs
Log events
/SP/logs/event
Designations for event log
/SP/logs/event/list
Designations for event log
/SP/network
External network interface
/SP/services
Available services
/SP/services/http
HTTP service
/SP/services/https
HTTPS service
/SP/services/https/ssl
HTTPS SSL certificate settings
/SP/services/https/ssl/custom_cert
Custom SSL certificate settings
/SP/services/https/ssl/custom_key
Custom SSL private key settings
/SP/services/https/ssl/default_cert
Default SSL certificate settings
/SP/services/ipmi
Management of the IPMI service
/SP/services/servicetag
Service Tag configuration
/SP/services/snmp
SNMP agent service configuration
/SP/services/snmp/communities
SNMP communities
/SP/services/snmp/communities/private
SNMP community
/SP/services/snmp/communities/public
SNMP community
/SP/services/snmp/users
SNMP users
/SP/sessions
Session description
/SP/users
User description
Related Information