Go to main content

SPARC T5-4 Server Service Manual

Exit Print View

Updated: February 2019
 
 

Determine Which DIMM Is Faulty (DIMM Fault Remind Button)

DIMMs are cold-service components that can be replaced by customers. For the location of the DIMMs, see Processor Module Components.


Caution

Caution  - This procedure requires that you handle components that are sensitive to electrostatic discharge. This discharge can cause failure of server components.


  1. Consider your first steps:
  2. Locate the DIMM Fault Remind button on the processor module.
    image:Graphic showing the location of the DIMM Fault Remind button on the motherboard.
  3. Verify that the DIMM Fault Remind Power LED next to the button is illuminated.

    An illuminated DIMM Fault Remind Power LED indicates that there is power available to illuminate the faulty DIMM LED once you have pressed the DIMM Fault Remind button.

  4. Press the DIMM Fault Remind button on the processor module.

    This will cause DIMM Fault LED associated with the faulty DIMM to illuminate for a few minutes.

  5. Note the DIMM next to the illuminated DIMM Fault LED.
  6. Ensure that all other DIMMs are seated correctly in their slots.

Related Information