Go to main content

SPARC T5-4 Server Service Manual

Exit Print View

Updated: February 2019
 
 

Determine Which PCIe Card Is Faulty

The following LEDs are illuminated when a fault is detected:

  • System Service Required LEDs on the front panel and rear I/O module

  • System PCIe Fault LED on the front panel

  • Service Required LED on card carrier containing the faulty PCIe card

  1. Determine if the System Service Required LEDs are illuminated on the front panel or the rear I/O module.

    See Interpreting LEDs.

  2. Determine if the PCIe Fault LED is illuminated on the front panel.

    See Front Panel Controls and LEDs.

  3. From the rear of the server, find the PCIe carrier that has an amber Service Required LED lit.
  4. Remove the faulty PCIe card.

    See Remove a PCIe Card Carrier.

Related Information