JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Flash Accelerator F40 PCIe Card

User's Guide

search filter icon
search icon

Document Information

Using This Documentation

Product Notes

Related Documentation

Feedback

Access to Oracle Support

Sun Flash Accelerator F40 PCIe Card Overview

Card Overview

About the Sun Flash Accelerator F40 PCIe Card

Key Features

Card Hardware Components

Card Software and Firmware Components

Card LEDs

Card Specifications

Physical Dimensions

Environmental Specifications

Electrical Specifications

Preparing the Card for Installation

Required Tools

Ship Kit Contents

Observing Safety Precautions

General Safety Information

Safety Symbols

ESD Safety Measures

Perform ESD Prevention Measures

Update the Host Operating System

Installing the Card

Installation Overview

Installing the Card Into a Server

Card Optimization Guidelines

Install a New Card

Remove an Existing Card From a Server

Servicing the Card

Service Overview

Update the Card Software

Update the Card Firmware

Technical Support

Servicing the Card Using the ddcli Utility

Accessing the ddcli Utility

Access Text Menu Interface in ddcli Utility

Access Command Line Interface (CLI) in ddcli Utility

Verify Card Status

ddcli Utility Command Summary

List All Command

List Command

Update Flash Package Command

Health Reporting Command

Locate Card Command

Format Card Command

Show the Vital Product Data Command

Extract SMART Logs Command

Help Command

Troubleshooting Using Card LEDs

Error Messages

Exception Handling

Firmware Exception Error Messages

Reason Codes

Index

List All Command

The -listall command identifies all Sun Flash Accelerator F40 PCIe Cards installed in a server.

The following information is displayed with the -listall command:

Text Menu Interface Usage: The ddcli utility lists seven commands. Type 1 to list all installed Sun Flash Accelerator F40 PCIe Cards installed in a server, as shown in the following example:

# ddcli
 
1.    List WarpDrive Information
2.    Update Flash Package
3.    Display WarpDrive Health
4.    Locate WarpDrive
5.    Format WarpDrive
6.    Show Vital Product Data
7.    Extract SMART Logs
Select Operation [1-7 or 0:Quit]: 1
 

Command Line Interface Usage: Enter the following line of text in the CLI to run the -listall command: ddcli -listall

The -listall command runs without any command line parameter. You need not specify the -c option on the command line.

Sample Output: When the -listall command runs, the ddcli utility outputs the following text. Two Sun Flash Accelerator F40 PCIe Cards are shown in the following example:

ID    WarpDrive     Package Version    PCI Address
--    ---------     ---------------    -----------
1     ELP-4x100-4d-n    06.05.10.00        00:09:00:00
2     ELP-4x100-4d-n    06.05.10.00        00:05:00:00
 
Related Information